Search NASA⌕ Search

Engineering topics

Vaughn, Timothy L.

Publications and source records attributed to Vaughn, Timothy L..

Methane Exhaust Measurements at Gathering Compressor Stations in the United States

Unburned methane entrained in exhaust from natural gas-fired compressor engines (“combustion slip”) can account for a substantial portion of station-level methane emissions. A novel in-stack, tracer gas method was coupled with Fourier transform infrared (FTIR) species measurements to quantify combustion slip from natural gas compressor engines at 67 gathering and boosting stations owned or managed by nine “study partner” operators in 11 U.S. states. The mean methane emission rate from 63 four-stroke, lean-burn (4SLB) compressor engines was 5.62 kg/h (95% CI = 5.15–6.17 kg/h) and ranged from 0.3 to 12.6 kg/h. The mean methane emission rate from 39 fourstroke, rich-burn (4SRB) compressor engines was 0.40 kg/h (95% CI = 0.37– 0.42 kg/h) and ranged from 0.01 to 4.5 kg/h. Study results for 4SLB engines were lower than both the U.S. EPA compilation of air pollutant emission factors (AP-42) and Inventory of U.S. Greenhouse Gas Emissions and Sinks (GHGI) by 8 and 9%, respectively. Study results for 4SRB engines were 43% of the AP-42 emission factor and 8% of the GHGI emission factor, the latter of which does not distinguish between engine types. Total annual combustion slip from the U.S. natural gas gathering and boosting sector was modeled using measured emission rates and compressor unit counts from the U.S. EPA Greenhouse Gas Reporting Program. Modeled results [328 Gg/y (95% CI = 235–436 Gg/y) of unburned methane] would account for 24% (95% CI = 17–31%) of the 1391 Gg of methane emissions for “Gathering and Boosting Stations”, or 6% of the net emissions for “Natural Gas Systems” (5598 Gg) as reported in the 2020 U.S. EPA GHGI. In conclusion, gathering and boosting combustion slip emissions reported in the 2020 GHGI (374 Gg) fall within the uncertainty of this model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temporal variability largely explains top-down/bottom-up difference in methane emission estimates from a natural gas production region

Here, this study spatially and temporally aligns top-down and bottom-up methane emission estimates for a natural gas production basin, using multiscale emission measurements and detailed activity data reporting. We show that episodic venting from manual liquid unloadings, which occur at a small fraction of natural gas well pads, drives a factor-of-two temporal variation in the basin-scale emission rate of a US dry shale gas play. The midafternoon peak emission rate aligns with the sampling time of all regional aircraft emission studies, which target well-mixed boundary layer conditions present in the afternoon. A mechanistic understanding of emission estimates derived from various methods is critical for unbiased emission verification and effective greenhouse gas emission mitigation. Our results demonstrate that direct comparison of emission estimates from methods covering widely different timescales can be misleading.

03 NATURAL GAS↗

Gathering pipeline methane emissions in Fayetteville shale pipelines and scoping guidelines for future pipeline measurement campaigns

Gathering pipelines, which transport gas from well pads to downstream processing, are a sector of the natural gas supply chain for which little measured methane emissions data are available. This study performed leak detection and measurement on 96 km of gathering pipeline and the associated 56 pigging facilities and 39 block valves. The study found one underground leak accounting for 83% (4.0 kg CH 4 /hr) of total measured emissions. Methane emissions for the 4684 km of gathering pipeline in the study area were estimated at 402 kg CH 4 /hr [95 to 1065 kg CH 4 /hr, 95% CI], or 1% [0.2% to 2.6%] of all methane emissions measured during a prior aircraft study of the same area. Emissions estimated by this study fall within the uncertainty range of emissions estimated using emission factors from EPA's 2015 Greenhouse Inventory and study activity estimates. While EPA's current inventory is based upon emission factors from distribution mains measured in the 1990s, this study indicates that using emission factors from more recent distribution studies could significantly underestimate emissions from gathering pipelines. To guide broader studies of pipeline emissions, we also estimate the fraction of the pipeline length within a basin that must be measured to constrain uncertainty of pipeline emissions estimates to within 1% of total basin emissions. The study provides both substantial insight into the mix of emission sources and guidance for future gathering pipeline studies, but since measurements were made in a single basin, the results are not sufficiently representative to provide methane emission factors at the regional or national level.

03 NATURAL GAS↗

Comparing facility-level methane emission rate estimates at natural gas gathering and boosting stations

Coordinated dual-tracer, aircraft-based, and direct component-level measurements were made at midstream natural gas gathering and boosting stations in the Fayetteville shale (Arkansas, USA). On-site component-level measurements were combined with engineering estimates to generate comprehensive facility-level methane emission rate estimates ('study on-site estimates (SOE)') comparable to tracer and aircraft measurements. Combustion slip (unburned fuel entrained in compressor engine exhaust), which was calculated based on 111 recent measurements of representative compressor engines, accounts for an estimated 75% of cumulative SOEs at gathering stations included in comparisons. Measured methane emissions from regenerator vents on glycol dehydrator units were substantially larger than predicted by modelling software; the contribution of dehydrator regenerator vents to the cumulative SOE would increase from 1% to 10% if based on direct measurements. Concurrent measurements at 14 normally-operating facilities show relative agreement between tracer and SOE, but indicate that tracer measurements estimate lower emissions (regression of tracer to SOE = 0.91 (95% CI = 0.83-0.99), R2 = 0.89). Tracer and SOE 95% confidence intervals overlap at 11/14 facilities. Contemporaneous measurements at six facilities suggest that aircraft measurements estimate higher emissions than SOE. Aircraft and study on-site estimate 95% confidence intervals overlap at 3/6 facilities. The average facility level emission rate (FLER) estimated by tracer measurements in this study is 17-73% higher than a prior national study by Marchese et al.

03 NATURAL GAS↗

Comparison of methane emission estimates from multiple measurement techniques at natural gas production pads

This study presents the results of a campaign that estimated methane emissions at 268 gas production facilities in the Fayetteville shale gas play using onsite measurements (261 facilities) and two downwind methods - the dual tracer flux ratio method (Tracer Facility Estimate - TFE, 17 facilities) and the EPA Other Test Method 33a (OTM33A Facility Estimate - OFE, 50 facilities). A study onsite estimate (SOE) for each facility was developed by combining direct measurements and simulation of unmeasured emission sources, using operator activity data and emission data from literature. The SOE spans 0-403 kg/h and simulated methane emissions from liquid unloadings account for 88% of total emissions estimated by the SOE, with 76% (95% CI [51%-92%]) contributed by liquid unloading at two facilities. TFE and SOE show overlapping 95% CI between individual estimates at 15 of 16 (94%) facilities where the measurements were paired, while OFE and SOE show overlapping 95% CI between individual estimates at 28 of 43 (65%) facilities. However, variance-weighted least-squares (VWLS) regressions performed on sets of paired estimates indicate statistically significant differences between methods. The SOE represents a lower bound of emissions at facilities where onsite direct measurements of continuously emitting sources are the primary contributor to the SOE, a sub-selection of facilities which minimizes expected inter-method differences for intermittent pneumatic controllers and the impact of episodically-emitting unloadings. At 9 such facilities, VWLS indicates that TFE estimates systematically higher emissions than SOE (TFE-to-SOE ratio = 1.6, 95% CI [1.2 to 2.1]). At 20 such facilities, VWLS indicates that OFE estimates systematically lower emissions than SOE (OFE-to-SOE ratio of 0.41 [0.26 to 0.90]). Given that SOE at these facilities is a lower limit on emissions, these results indicate that OFE is likely a less accurate method than SOE or TFE for this type of facility.

03 NATURAL GAS↗