Technical Basis for Extending Storage Life of DOE-STD-3013 Containers

The U.S. Department of Energy (DOE) Technical Standard for Stabilization, Packaging, and Storage of Plutonium-Bearing Materials, DOE-STD-3013 [USDOE 2018], provides requirements for packaging stabilized metals, alloys, and oxides containing at least 30 weight percent (wt%) plutonium (Pu) plus uranium for storage for up to 50 years. This document provides the technical basis for extending that storage duration to up to 100 years for metals and alloys, and oxides that do not present a corrosion risk to the integrity of the container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selection of 3013 Containers for Field Surveillance (FY 2021 Update)

This Update is the ninth in a series of reports that document the binning and sample selection of 3013 containers for the Field Surveillance program as part of the Integrated Surveillance Program. The last Update was in 2016. This Update documents changes to the binning and changes to the random and engineering judgment samples since 2016. This Update also documents field surveillance activities since 2016 and describes plans to complete random sampling in 2025. In addition, this Update describes a new effort to collect surveillance data as part of down blending operations and updates assumptions about Advanced Recovery and Integrated Extraction System (ARIES) 3013 containers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparing elemental measurements at packaging and after storage for signatures of chloride salt radiolysis

Radiolysis of hydrated alkaline earth chloride salts by alpha radiation from plutonium produces the chloride containing gases HCl and Cl 2 . These gases are known to diffuse out of the plutonium-containing material and contribute to corrosion outside of the convenience container. The alkaline earth elements remain with the plutonium-containing material as oxides or hydroxides. The amount of chlorine within the material after storage will be reduced compared to the amount at packaging. The fraction of the alkaline earth elements that are soluble after storage will be reduced compared to the amount at packaging. These signatures may be observable by comparing the chemical analysis measurements made at packaging and after storage. Comparison of measurements on a single Hanford container shows that the chloride does decrease and the alkaline earth elements have reduced solubility in water. Differences seen with other elements make conclusions difficult.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of the Corrosion Risks to a Double Shell Tank During the Selective Removal of a Cesium-rich Supernate Layer - 20227

The Direct Feed Low Activity Waste (DF-LAW) activity will provide the initial feed to the Waste Treatment and Immobilization Plant at the Hanford Tank Farm facility. Feed preparation for DF-LAW will be carried out in multiple double shell waste tanks (DST) utilizing the Tank Side Cesium Removal (TSCR) process. Tank AP-106 will be an integral part of the TSCR process and hence key to the DFLAW activity. Prior to being utilized for this purpose, the Cs-137 concentration levels in the AP-106 supernate must be reduced significantly. The AP-106 re-purposing process manages normal waste tank addition procedures such that waste acceptance criteria objectives for Cs-137 removal are achieved. As this process was being developed, several concerns regarding tank integrity during and after repurposing of Tank AP-106, and the associated tanks (i.e., AP-102, AN-101, and AP-108), were addressed. The potential corrosion degradation mechanisms identified based on process knowledge included: general and pitting corrosion, caustic stress corrosion cracking, concentration cell corrosion, and microbiologically induced corrosion (MIC). A systematic approach was undertaken to assess the risk of corrosion during the AP-106 re-purposing process. The assessment considered the initial and present condition of the tank, the service history of the tank, the environmental conditions created in each tank during each stage of the process, process timing, and corrosion testing and modeling that approximated tank conditions. Based on this information, recommendations were provided to minimize the exposure of the tank to corrosive conditions. These recommendations included time limits for each stage of the process, staging of corrosion inhibitor solutions should process delays occur, and waste sampling with potential chemistry adjustments at defined steps in the process. Additionally, recommendations for post-process supernate chemistry adjustments and tank inspections were put forth. The greatest risk for this process occurs during the manipulation of large quantities of Columbia River water (i.e., greater than 450,000 gallons) within AP-106, the associated tanks and the supporting infrastructure (i.e., transfer line piping). This risk becomes more pronounced if there is a process upset and the tank walls remain exposed to a corrosive condition longer than intended. As long as the river water is blended into the supernate in a timely fashion, and the waste is adjusted appropriately with corrosion inhibitors, corrosion may be minimized and the final condition of the supernate in AP-106 and the associated tanks is expected to be in compliance with corrosion chemistry requirements. Contingency plans will be made to minimize the impact of a process upset. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection and Mitigation of Hanford Site Radioactive Waste Tank Surface Water Intrusion - 16396

The last single-shell underground radioactive waste storage tanks at the U.S. Department of Energy's Hanford Site, near Richland, WA, were removed from service in November, 1980. At that time the single-shell tanks contained 153,300 m{sup 3} (40.5 million gallons) of waste, including 34,400 m{sup 3} (9.1 million gallons) of liquids. Subsequently the Interim Stabilization Program and Waste Retrieval/Closure Project have removed 24,600 m{sup 3} (6.5 million gallons) of liquid from the tanks to reduce the potential for leakage to the environment. After interim stabilization, each tank was isolated by cutting and capping waste transfer lines, filling drains with grout, and covering likely surface water entry points. The minimum expected lifetime for the isolation features was 20 years, consistent with planned retrieval of all single-shell tank wastes by 2018. Since then the retrieval completion date has been extended. In 2011 the Tank Operating Contractor began a systematic review of the aging isolation barriers to determine if surface water was entering the single-shell tanks. This paper summarizes the results of the 2011 - 2015 activities including single-shell tank inspection results, methodologies used to identify intrusions and waste leaks masked by intrusion, and eventual deployment of a prototype forced ventilation exhauster in 2015 to evaporate water intrusion pools on the waste surface. Further efforts to limit water intrusion, including deployment of surface barriers, are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Separation of Plutonium from Irradiated Fuels and Targets

Spent nuclear fuel from power production reactors contains moderate amounts of transuranium (TRU) actinides and fission products in addition to the still slightly enriched uranium. Originally, nuclear technology was developed to chemically separate and recover fissionable plutonium from irradiated nuclear fuel for military purposes. Military plutonium separations had essentially ceased by the mid-1990s. Reprocessing, however, can serve multiple purposes, and the relative importance has changed over time. In the 1960’s the vision of the introduction of plutonium-fueled fast-neutron breeder reactors drove the civilian separation of plutonium. More recently, reprocessing has been regarded as a means to facilitate the disposal of high-level nuclear waste, and thus requires development of radically different technical approaches. In the last decade or so, the principal reason for reprocessing has shifted to spent power reactor fuel being reprocessed (1) so that unused uranium and plutonium being recycled reduce the volume, gaining some 25% to 30% more energy from the original uranium in the process and thus contributing to energy security and (2) to reduce the volume and radioactivity of the waste by recovering all long-lived actinides and fission products followed by recycling them in fast reactors where they are transmuted to short-lived fission products; this reduces the volume to about 20%, reduces the long-term radioactivity level in the high-level waste, and complicates the possibility of the plutonium being diverted from civil use – thereby increasing the proliferation resistance of the fuel cycle. In general, reprocessing schemes can be divided into two large categories: aqueous/hydrometallurgical systems, and pyrochemical/pyrometallurgical systems. Worldwide processing schemes are dominated by the aqueous (hydrometallurgical) systems. This document provides a historical review of both categories of reprocessing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress of the Enhanced Hanford Single Shell Tank (SST) Integrity Project

To improve the understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Double-Shell Tank Construction: Extent of Condition

This presentation covers: quick recap of Hanford DSTs and the contribution of construction difficulties which led to the leak in tank AY-102; approach to Extent of Condition reviews; typical DST construction sequence; presentation of construction information resulting from extent of condition reviews of other DST farms with comparison to tank AY-102; and overall conclusion and impact of issues on the other DST tank farms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

241-AY-102 Leak Detection Pit Drain Line Inspection Report

This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double-Shell Tank Extent-of-Condition Construction Review

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. The formal leak assessment, documented in RPP-ASMT-53793,Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure. To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records were performed for the first three DST tank farms constructed, which included tanks 241-AY-101, 241-AZ-101, 241-AZ-102, 241-SY-101, 241-SY-102, and 241-SY-103. The review for these six tanks involved research and review of dozens of boxes of historical project documentation. These reviews form a basis to better understand the current condition of the three oldest Hanford DST farms. They provide a basis for changes to the current tank inspection program and also provide valuable insight into future tank use decisions. If new tanks are constructed in the future, these reviews provide valuable "lessons-learned" information about expected difficulties as well as construction practices and techniques that are likely to be successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

241-AZ Tank Farm Construction Extent of Condition Review for Tank Integrity

This report provides the results of an extent of condition construction history review for tanks 241-AZ-101 and 241-AZ-102. The construction history of the 241-AZ tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AZ tank farm, the second DST farm constructed, both refractory quality and tank and liner fabrication were improved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

241-SY Tank Farm Construction Extent of Condition Review for Tank Integrity

This report provides the results of an extent of condition construction history review for tanks 241-SY-101, 241-SY-102, and 241-SY-103. The construction history of the 241-SY tank farm has been reviewed to identify issues similar to those experienced during tank 241-AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank 241-AY-102 as the comparison benchmark. In the 241-SY tank farm, the third DST farm constructed, refractory quality and stress relief were improved, while similar tank and liner fabrication issues remained.