Venkataraman, Ram

Publications and source records attributed to Venkataraman, Ram.

Measurement of the Effective Capture Cross Section of 238 Np in the High Flux Isotope Reactor

The cross sections of 237 Np and 238 Np are important for accurate modeling and simulation of 238 Pu in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). Uncertainties in these cross sections can impact the ability to predict and optimize the target design and loading for 238 Pu production targets. The effective capture cross section of 237 Np in the location of pneumatic tube 1 in HFIR was measured as a first step in the measurement of the 238 Np capture and fission cross sections. Here, we describe the flux measurements, 237 Np experiments, and data analysis of the 237 Np capture cross section in HFIR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Basics of Gamma Ray Detection

The objective of this training is to explain the origin of x-rays and gamma rays, gamma ray interactions with matter, detectors and electronics used in gamma ray-spectrometry, and features of a gamma-ray spectrum for nuclear material that is safeguarded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of general purpose mathematical efficiency modeling with ISOCS - 15579

Gamma spectroscopy is a commonly used method for radioactive waste characterization and activity determination in in-situ objects. The gamma rays emitted by radionuclides in the waste container matrix are highly penetrating and can be measured using one or more gamma ray detectors, thus allowing for a passive nondestructive assay. One problem is that a source based calibration of full energy peak efficiency can be difficult or impractical because of the large size and/or an unusual shape of the sample geometry. One attractive solution is to use mathematical efficiency modeling to calculate the full energy peak efficiency. The In-Situ Object Calibration Software (ISOCS) has successfully been used for more than a decade for mathematical efficiency modeling of template based geometries. Templates include the most common objects in waste characterization and D and D, including but not limited to: boxes, drums, and pipes with hotspots, beams, tanks and walls. Scenarios exist where these templates cannot model the desired measurement geometry. Canberra has developed a general purpose version of ISOCS where primitive objects can be combined into practically any geometry. The primitive objects are right circular cylinder, right elliptical cylinder, right circular cone, right elliptical cone, sphere, spheroid, ellipsoid, box (rectangular parallelepiped), torus, and beaker (any cylindrical symmetric object). Multiple primitive objects can be combined using the priority scheme and cut by planes into almost any desired shape. In addition, multiple objects can be defined in the same scene, for example cylinders next to each other or a pipe and a box. Collimators can be constructed as easily as in template based ISOCS. The ray tracing algorithm in ISOCS has been extended to support the new primitive objects for attenuation calculation between the radioactive source and the detector end cap. The new version uses the same vacuum efficiency response, or characterization, in the energy range 10 - 7000 keV of individual detectors to be able to calculate the efficiency as accurately as possible. MCNP has been shown to be able to calculate detection efficiencies for any geometry and the new version of ISOCS have been validated to MCNP. The vacuum efficiency is based on an MCNP model and this model was the base for constructing an identical model in MCNP as in ISOCS. The calculated efficiencies from the two codes have been compared and the agreement is within 3% except for the lowest energies for one geometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model-based approaches to calibration and certification of nondestructive assay systems - 15615

Increasingly, model-based methods founded in physics are employed to calibrate, or extend the calibration of, nondestructive assay (NDA) systems used to characterize materials contaminated with plutonium, uranium, and other radioactive isotopes. In addition, modeling and mathematical methods are used to establish system parameters, correction factors, and measurement uncertainty components in NDA measurements. The methods combine the characteristics of the measurement configuration (detector structure, object shape and dimensions, source-detector distance and orientation, and collimation), generator knowledge of the waste composition, and known physical properties of the system in order to establish these parameters, factors, and components. These methods offer several important benefits over traditional methods used to test, calibrate, operate, and certify radiation measurement systems. First, instruments can be set up and put into service more quickly and correctly using a model-based approach. Second, calibrations can be performed, tested, and modified with reduced use of plutonium and uranium standards when modeling and mathematical methods are employed. Also, modeled approaches avoid calibration error resulting from heterogeneous source distribution. Moreover, the parameters can be installed quickly and simply in an office setting without the need for the safety, security, and safeguards considerations that are present when standards are used. Calibrations can also be tailored to fit unique or nonstandard container configurations (for example, over-packed drums), new container types, or specialized matrices. Finally, when modeling methods are applied, correction factors and measurement uncertainty elements can be developed, tested, and validated relatively quickly and without the need for surrogate matrix materials and a large number of test measurements. A combined gamma and neutron NDA system has recently been moved from Idaho National Laboratory to the TA 55 facility at Los Alamos National Laboratory (LANL). The system will be used to assay transuranic waste packaged in drums. After the move, the system was modified to replace degraded components and improve system performance. Afterwards, it was set up to assay different container types and to extend the calibration range. Model-based approaches were used to adapt the system to its new purpose at LANL. This report will describe the setup, calibration, and certification of the combined system at LANL Included in this discussion will be the measurement applications and details of the measurement methods. The steps in these processes that involved the use of modeling and mathematical calculations to replace or supplement more traditional methods will be identified and discussed. Finally, an overarching discussion of the methods and advantages of model-based methods to establish the properties of NDA systems will be presented. We conclude that validated mathematical methods offer a robust, flexible, and mature approach which is technically defensible from first principle physics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimum detectable activity for tomographic gamma scanning system - 15648

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each 'view' is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimum Detectable Activity for Tomographic Gamma Scanning System

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗