Search NASA⌕ Search

Engineering topics

Vennekate, John

Publications and source records attributed to Vennekate, John.

RF AND MECHANICAL DESIGN OF A 915 MHz SRF CAVITY FOR CONDUCTION-COOLED CRYOMODULES

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi↗

RF and Mechanical Design of a 915 MHz SRF Cavity for Conduction-Cooled Cryomodules

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915 MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi↗

Compact Superconducting RF Accelerators for Water Treatment

Jefferson Lab is actively exploring the environmental applications of compact irradiation facilities utilizing Superconducting Radio Frequency (SRF) accelerator technology ? a well-established technology primarily used in large research machines. Recent advancements, such as the application of thin films of superconducting alloys in radio frequency (RF) resonators and the development of high-capacity cryocoolers, have made it feasible to employ this key technology in compact, standalone irradiation facilities. The main advantage over conventional systems based on normal conducting technology is the significantly enhanced efficiency in beam power generation, enabling exposure to substantially higher radiation doses. In the realm of addressing contaminants in wastewater treatment, particularly concerning persistent substances known as "forever chemicals," this technology presents an attractive solution, given the required considerable effort i.e. dose to break them down. Experiment Numbers:

Vennekate, John↗

Compact Superconducting RF Accelerators for Water Treatment

Jefferson Lab is actively exploring the environmental applications of compact irradiation facilities utilizing Superconducting Radio Frequency (SRF) accelerator technology ? a well-established technology primarily used in large research machines. Recent advancements, such as the application of thin films of superconducting alloys in radio frequency (RF) resonators and the development of high-capacity cryocoolers, have made it feasible to employ this key technology in compact, standalone irradiation facilities. The main advantage over conventional systems based on normal conducting technology is the significantly enhanced efficiency in beam power generation, enabling exposure to substantially higher radiation doses. In the realm of addressing contaminants in wastewater treatment, particularly concerning persistent substances known as "forever chemicals," this technology presents an attractive solution, given the required considerable effort i.e. dose to break them down. Experiment Numbers:

Vennekate, John↗

LCLS-II-HE Cavity Qualification Testing

Acceptance testing of the LCLS-II-HE production cavities is approximately 65% complete. In this report, we present details of the test results, including summaries of the quench fields, intrinsic quality factors, and experience with field emission. We also offer an outlook on the remaining tests to be performed.

43 PARTICLE ACCELERATORS↗

Flux Expulsion Testing for LCLS-II-HE Cavity Production

Nitrogen-doped niobium SRF cavities are sensitive to trapped magnetic flux, which decreases the cavity intrinsic Q₀. Prior experimental results have shown that heat treatments to 900°C and higher can result in stronger flux expulsion during cooldown; the precise temperature required tends to vary by vendor lot/ingot of the niobium material used in the cavity cells. For LCLS-II-HE, to ensure sufficient flux expulsion in all cavities, we built and tested single-cell cavities to determine this required temperature for each vendor lot of niobium material to be used in cavity cells. In this report, we present the results of the single-cell flux expulsion testing and the Q₀ of the nine-cell cavities built using the characterized vendor lots. We discuss mixing material from different vendor lots, examine the lessons learned, and finally present an outlook on possible refinements to the single-cell technique.

43 PARTICLE ACCELERATORS↗

Electron beam treatment for the removal of 1,4-dioxane in water and wastewater

Electron beam (e-beam) treatment uses accelerated electrons to form oxidizing and reducing radicals when applied to water without the use of external chemicals. In this study, electron beam treatment was used to degrade 1,4-dioxane in several water matrices. Removal improved in the progressively cleaner water matrices and removals as high as 94% to 99% were observed at a dose of 2.3 kGy in secondary effluent. 1,4-dioxane removal was confirmed to be primarily through hydroxyl radical oxidation. The calculated electrical energy per order was found to be 0.53, 0.26, and 0.08 kWh/m 3 /order for secondary effluent (Avg. total organic carbon (TOC) 9.25 mg/L), granular activated carbon effluent (TOC 3.46 mg/L), and ultrapure water, respectively, with a 70% generation and transfer efficiency applied.

1,4-dioxane↗