Search NASASearch

Engineering topics

Vikhlinin, A.

Publications and source records attributed to Vikhlinin, A..

Development Status of Adjustable X-Ray Optics with 0.5 Arcsecond Resolution

We report on the continuing development of adjustable, grazing incidence X-ray optics for 0.5 arcsec telescopes. Adjustable X-ray optics offer the potential for achieving sub-arcsecond imaging resolution while sufficiently thin and light-weight to constitute a mirror assembly with several square meters collecting area. The adjustable mirror concept employs a continuous thin film of piezoelectric material deposited on the back of the paraboloid and hyperboloid mirror segments. Individually addressable electrodes on the piezoelectric layer allow the introduction of deformations in localized "cells" which are used to correct mirror figure errors resulting from fabrication, mounting and aligning the thin mirrors, residual gravity release and temperature changes. We describe recent results of this development. These include improving cell yield to approx. 100 per cent, measurements of hysteresis and stability, comparisons of modeled and measured behavior, simulations of mirror performance, and the development and testing of conical Wolter- I mirror segments. We also present our plans going forward toward the eventual goal of achieving TRL 6 prior to the 2020 Decadal Review.

Reid, P. B.

Development Roadmap for an Adjustable X-Ray Optics Observatory

We are developing adjustable X-ray optics to use on a mission such as SMART-X (see posters 38.02, 38.03 and Presentation 30.03). To satisfy the science problems expected to be posed by the next decadal survey, we anticipate requiring effective area greater than 1 square meter and Chandra-like angular resolution: approximately equal to 0.5 inches. To achieve such precise resolution we are developing adjustable mirror technology for X-ray astronomy application. This uses a thin film of piezoelectric material deposited on the back surface of the mirror to correct for figure distortions, including manufacturing errors and deflections due to gravity and thermal effects. We present here a plan to raise this technology from its current Level 2, to Level 6, by 2018.

Schwartz, Dan

ART-XC: A Medium-energy X-ray Telescope System for the Spectrum-R-Gamma Mission

The ART-XC instrument is an X-ray grazing-incidence telescope system in an ABRIXAS-type optical configuration optimized for the survey observational mode of the Spectrum-RG astrophysical mission which is scheduled to be launched in 2011. ART-XC has two units, each equipped with four identical X-ray multi-shell mirror modules. The optical axes of the individual mirror modules are not parallel but are separated by several degrees to permit the four modules to share a single CCD focal plane detector, 1/4 of the area each. The 450-micron-thick pnCCD (similar to the adjacent eROSITA telescope detector) will allow detection of X-ray photons up to 15 keV. The field of view of the individual mirror module is about 18 x 18 arcminutes(exp 2) and the sensitivity of the ART-XC system for 4 years of survey will be better than 10(exp -12) erg s(exp -1) cm(exp -2) over the 4-12 keV energy band. This will allow the ART-XC instrument to discover several thousand new AGNs.

Arefiev, V.

ART: Surveying the Local Universe at 2-11 keV

The Astronomical Rontgen Telescope (ART) is a medium-energy x-ray telescope system proposed for the Russian-led mission Spectrum Rontgen-Gamma (SRG). Optimized for performance over the 2-11-keV band, ART complements the softer response of the SRG prime instrument-the German eROSITA x-ray telescope system. The anticipated number of ART detections is 50,000-with 1,000 heavily-obscured (N(sub H)> 3x10(exp 23)/sq cm) AGN-in the SRG 4-year all-sky survey, plus a comparable number in deeper wide-field (500 deg(sup 2) total) surveys. ART's surveys will provide a minimally-biased, nearly-complete census of the local Universe in the medium-energy x-ray band (including Fe-K lines), at CCD spectral resolution. During long (approx.100-ks) pointed observations, ART can obtain statistically significant spectral data up to about 15 keY for bright sources and medium-energy x-ray continuum and Fe-K-line spectra of AGN detected with the contemporaneous NuSTAR hard-x-ray mission.

O'Dell, S. L.

ASCA Temperature Maps for Merging and Relaxed Clusters and Physics of the Cluster Gas

ASCA temperature maps for several galaxy clusters undergoing strong mergers will be presented. From these maps, it is possible to estimate velocities of the colliding subclusters. I will discuss several interesting implications of these estimates for the physics of the cluster gas and the shape of the gravitational potential. I will also present temperature maps and profiles for several relaxed clusters selected for X-ray mass determination, and present the mass values derived without the assumption of isothermality. The accurate mass-temperature and luminosity-temperature relations will be discussed. This talk will review how AXAF will revolutionize X-ray astronomy through its radically better imaging and spectroscopic resolution. Examples from many fields of astrophysics will be given.

Markevitch, M.

ASCA Temperature Maps for Several Interesting Clusters and Their Interpretations

We present ASCA temperature maps for several galaxy clusters with strong mergers, as well as for several relaxed clusters selected for X-ray mass determination. From the merger temperature maps, we estimate velocities of the colliding subunits and discuss several implications of these estimates. For the relaxed clusters, we derive unprecedentedly accurate mass and gas fraction profiles out to radii of overdensity approximately 500.

Markevitch, M.

Another collision for the Coma cluster

The wavelet transform analysis of the Rosat position sensitive proportional counter (PSPC) images of the Coma cluster are presented. The analysis shows, on small scales, a substructure dominated by two extended sources surrounding the two bright clusters NGC 4874 and NGC 4889. On scales of about 2 arcmin to 3 arcmin, the analysis reveals a tail of X-ray emission originating near the cluster center, curving to the south and east for approximately 25 arcmin and ending near the galaxy NGC 4911. The results are interpreted in terms of a merger of a group, having a core mass of approximately 10(exp 13) solar mass, with the main body of the Coma cluster.

Vikhlinin, A.

Mass concentrations associated with extended X-ray sources in the core of the Coma cluster

Using a deep (approx. 20,200 s) ROSAT Position Sensitive Proportional Counter (PSPC) image we have examined the central region of the Coma cluster. Two extended regions of enhanced X-ray emission are found, centered at the positions of the brightest elliptical galaxies in the cluster: NGC 4874 and NGC 4889. Spectral analysis of the sources reveals no evidence of any difference between the spectra of these sources and that of the surrounding cluster emission. We assume that the enhancement in the X-ray surface brightness results from gas density enhancements and also that the underlying mass concentrations lie either at the cluster center or 1 core radius out of the center (420 kpc). With these assumptions, we derive total masses of 1.2 x 10(exp 13) - 1.6 x 10(exp 13), and 0.9 x 10(exp 13) - 1.8 x 10(exp 13) Solar mass within 2 min (80 kpc) of NGC 4874 and NGC 4889, respectively, assuming a Hubble constant H(sub 0) = 50 km/s/Mpc. Corresponding mass-to-light ratios for the galaxies are 30-40 and 25-50 in solar units, increasing at larger radii and approaching the values derived for the entire cluster at distances of more than approximately 150 kpc from the galaxies.

Vikhlinin, A.