Search NASA⌕ Search

Engineering topics

Virostek, Steve P

Publications and source records attributed to Virostek, Steve P.

The Results of Recent MICE Superconducting Spectrometer Solenoid Test

The MICE spectrometer solenoid magnets will be the first magnets to be installed within the MICE cooling channel. The MICE spectrometer solenoids may be the largest magnets that have been cooled using small two stage coolers. During the previous test of this magnet, the cooler first stage temperatures were too high. The causes of some of the extra first stage heat load has been identified and corrected. The rebuilt magnet had a single stage GM cooler in addition to the three pulse tube coolers. The added cooler reduces the temperature of the top of the HTS leads, the shield and of the first stage of the pulse tube coolers.

42 ENGINEERING↗

Lessons Learned for the MICE Coupling Solenoid from the MICE Spectrometer Solenoids

Tests of the spectrometer solenoids have taught us some important lessons. The spectrometer magnet lessons learned fall into two broad categories that involve the two stages of the coolers that are used to cool the magnets. On the first spectrometer magnet, the problems were centered on the connection of the cooler 2nd-stage to the magnet cold mass. On the first test of the second spectrometer magnet, the problems were centered on the cooler 1st-stage temperature and its effect on the operation of the HTS leads. The second time the second spectrometer magnet was tested; the cooling to the cold mass was still not adequate. The cryogenic designs of the MICE and MuCOOL coupling magnets are quite different, but the lessons learned from the tests of the spectrometer magnets have affected the design of the coupling magnets.

42 ENGINEERING↗

The Results of Tests of the MICE Spectrometer Solenoids

The Muon Ionization Cooling Experiment (MICE) spectrometer solenoid magnets will be the first magnets to be installed within the MICE cooling channel. The spectrometer magnets are the largest magnets in both mass and surface area within the MICE ooling channel. Like all of the other magnets in MICE, the spectrometer solenoids are kept cold using 1.5 W (at 4.2 K) pulse tube coolers. The MICE spectrometer solenoid is quite possibly the largest magnet that has been cooled using small coolers. Two pectrometer magnets have been built and tested. This report discusses the results of current and cooler tests of both magnets.

42 ENGINEERING↗

Progress on Superconducting Magnets for the MICE Cooling Channel

The muon ionization cooling experiment (MICE) consists of a target, a beam line, a pion decay channel, the MICE cooling channel. Superconducting magnets are used in the pion decay channel and the MICE cooling channel. This report describes the MICE cooling channel magnets and the progress in the design and fabrication of these magnets. The MICE cooling channel consists of three types of superconducting solenoids; the spectrometer solenoids, the coupling solenoids and the focusing solenoids. The three types of magnets are being fabricated in he United States, China, and the United Kingdom respectively. The spectrometer magnets are used to analyze the muon beam before and after muon cooling. The coupling magnets couple the focusing sections and keep the muon beam contained within the iris of the RF cavities that re used to recover the muon momentum lost during ionization cooling. The focusing magnets focus the muon beam in the center of a liquid hydrogen absorber. The first of the cooling channel magnets will be operational in MICE in the spring of 2010.

42 ENGINEERING↗

Preliminary Test Results for the MICE Spectrometer Superconducting Solenoids

This report describes the MICE spectrometer solenoids as built. Each magnet consists of five superconducting coils. Two coils are used to tune the beam going from or to the MICE spectrometer from the rest of the MICE cooling channel. Three spectrometer coils (two end coils and a long center coil) are used to create a uniform 4 T field (to {+-}0.3 percent) over a length of 1.0 m within a diameter of 0.3 m. The three-coil spectrometer set is connected in series. The two end coils use small power supplies to tune the uniform field region where the scintillating fiber tracker is located. This paper will present the results of the preliminary testing of the first spectrometer solenoid.

42 ENGINEERING↗

The Design and Construction of the MICE Spectrometer Solenoids

The purpose of the MICE spectrometer solenoid is to provide a uniform field for a scintillating fiber tracker. The uniform field is produced by a long center coil and two short end coils. Together, they produce 4T field with a uniformity of better than 1% over a detector region of 1000 mm long and 300 mm in diameter. Throughout most of the detector region, the field uniformity is better than 0.3%. In addition to the uniform field coils, we have two match coils. These two coils can be independently adjusted to match uniform field region to the focusing coil field. The coil package length is 2544 mm. We present the spectrometer solenoid cold mass design, the powering and quench protection circuits, and the cryogenic cooling system based on using three cryocoolers with re-condensers.

42 ENGINEERING↗

The Dimensions and Number of Turns for the Tracker Solenoids As-Built compared to the Original Magnet Design

The two tracker solenoids for MICE [1]-[3] as-built are different from the original design proposed by Wang NMR [4]. The Wang NMR design is in turn different from the magnet design proposed in the original MICE tracker magnet specification [5]. The two tracker solenoids where fabricated with niobium titanium conductor supplied to LBNL by Luvata under a specification written by LBNL [6]. This report compares the as-built tracker solenoids to the original Wang NMR design [4]. The as-built solenoid coils are thicker by 5 to 8 percent than called for the original design. This means that the current center is moved outward from 0.2 to 0.5 percent. In both tracker magnets, the thickness of end coil 2 was increased by 2-layers over the original design [5]. Thus, the current center for end coil 2 was moved outward by 0.7 percent. The number of turns per layer was underestimated in the original design from 2 to 4 percent. As a result, the current in each of the five tracker solenoid coils must be increased. In turn, the two as built tracker solenoids are compared to each other. In the ways that matter, the two tracker solenoids are nearly identical to each other. The largest difference between the two magnets that matters is a 0.05 percent change in the current in the center coil of the three coil set that forms the spectrometer solenoid. Since this is the largest variation that matters, it can be concluded that coils M1, coils M2, and the spectrometer solenoid can be connected in series without affecting the beam dynamics of MICE. This includes the two tuned end coils as well. The position of the coils within the cryostats vacuum vessel appears to be acceptable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MICE Spectrometer Magnet System Progress

The first magnets for the muon ionization cooling experimentwill be the tracker solenoids that form the ends of the MICE coolingchannel. The primary purpose of the tracker solenoids is to provide auniform 4 T field (to better than +-0.3 percent over a volume that is 1meter long and 0.3 meters in diameter) spectrometer magnet field for thescintillating fiber detectors that are used to analyze the muons in thechannel before and after ionization cooling. A secondary purpose for thetracker magnet is the matching of the muon beam between the rest of theMICE cooling channel and the uniform field spectrometer magnet. Thetracker solenoid is powered by three 300 amp power supplies. Additionaltuning of the spectrometer is provided by a pair of 50 amp power suppliesacross the spectrometer magnet end coils. The tracker magnet will becooled using a pair of 4 K pulse tube coolers that each provide 1.5 W ofcooling at 4.2 K. Final design and construction of the tracker solenoidsbegan during the summer of 2006. This report describes the progress madeon the construction of the tracker solenoids.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗