Search NASA⌕ Search

Engineering topics

Visser, G.

Publications and source records attributed to Visser, G..

At least 19 records

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A D$_2$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2–3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

The STAR event plane detector

The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy collision between heavy nuclei. It consists of two highly-segmented disks of 1.2-cm-thick scintillator embedded with wavelength-shifting fiber, coupled to silicon photomultipliers and custom electronics. Finally, we describe the general design of the device, its construction, and performance on the bench and in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The evolution of the STAR Trigger System

The STAR experiment at RHIC has been taking data since 2000. During that time, new detectors have been added, RHIC luminosity has increased, and STAR’s physics goals have become more focused. The Trigger System has evolved in parallel to be able to provide more precise triggering capabilities at higher rates. In this article the major improvements to the STAR Trigger are described, along with the future upgrade path.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-rate axial-field ionization chamber for particle identification of radioactive beams

The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams ( < 5 MeV / A ) the detector presents only three 0.5 µm/cm 2 foils to the beam in addition to the detector gas. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a risetime of 60–70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate and providing a time resolution of 6–8 ns. Tests with an α source establish the detector energy resolution as ~ 8 % for an energy deposit of ~3.5 MeV. The energy resolution with beams of 2.5 and 4.0 MeV/A 39 K ions and the dependence of the energy resolution on beam intensity is measured. At an instantaneous rate of 3×10 5 ions/s the energy resolution has degraded to 14% with a pileup of 12%. The good energy resolution of this detector at rates up to 3×10 5 ions/s makes it an effective tool in the characterization of low-energy radioactive beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗