Oxidative Electrochemical Coupling Between Bi and Mn in Rechargeable Alkaline MnO2 Cathodes
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Vo, Nghia T..
Explore the source record for details and available documents.
The aqueous zinc-sulfur battery holds promise for significant capacity and energy density with low cost and safe operation based on environmentally benign materials. However, it suffers from the sluggish kinetics of the conversion reaction. Here, we highlight the efficacy of molybdenum(IV) sulfide (MoS 2 ) to reduce the overpotential of S-ZnS conversion in aqueous electrolytes and study the discharge products formed at the solid-solid and solid-liquid interfaces using experimental and theoretical approaches. Specifically, the MoS 2 -catalyzed electrochemical conversion reaction is characterized via ex situ X-ray diffraction (XRD), transmission electron microscopy (TEM) with energy dispersive spectroscopy (EDS), Raman spectroscopy, synchrotron-based Mo K-edge X-ray absorption spectroscopy (XAS), and in situ synchrotron-based X-ray computed tomography (XCT). Additionally, operando synchrotron-based S K-edge XAS and X-ray fluorescence (XRF) maps are collected to determine the spatial evolution of sulfur-based species at the electrode-electrolyte interface. Further, coupling the operando S K-edge XAS data with the simulated spectra and fitting the data suggested a possible ZnS 2 intermediate phase.
Explore the source record for details and available documents.
Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.
As the energy density of lithium-ion cells and batteries increases, controlling the outcomes of thermal runaway becomes more challenging. If the high rate of gas generation during thermal runaway is not adequately vented, commercial cell designs can rupture and explode, presenting serious safety concerns. Here, ultra-high-speed synchrotron X-ray imaging is used at >20 000 frames per second to characterize the venting processes of six different 18650 cell designs undergoing thermal runaway. For the first time, the mechanisms that lead to the most catastrophic type of cell failure, rupture, and explosion are identified and elucidated in detail. The practical application of the technique is highlighted by evaluating a novel 18650 cell design with a second vent at the base, which is shown to avoid the critical stages that lead to rupture. The insights yielded in this study shed new light on battery failure and are expected to guide the development of safer commercial cell designs.
Lithium-ion batteries are being used in increasingly demanding applications where safety and reliability are of utmost importance. Thermal runaway presents the greatest safety hazard, and needs to be fully understood in order to progress towards safer cell and battery designs. Here, we demonstrate the application of an internal short circuiting device for controlled, on-demand, initiation of thermal runaway. Through its use, the location and timing of thermal runaway initiation is pre-determined, allowing analysis of the nucleation and propagation of failure within 18 650 cells through the use of high-speed X-ray imaging at 2000 frames per second. Furthermore, the cause of unfavourable occurrences such as sidewall rupture, cell bursting, and cell-to-cell propagation within modules is elucidated, and steps towards improved safety of 18 650 cells and batteries are discussed.
X-ray in-line phase contrast tomography holds great promise for the quantitative analysis of soft materials. However, its applications have been limited, so far, by the fact that direct methods based on the transport-of-intensity equation and the contrast transfer function are sensitive to noise and applicable only to limited types of samples. Here, we propose an iterative method based on the Gerchberg-Saxton algorithm (R. W. Gerchberg and W. O. Saxton, Optik 35, 237 (1972)), but overcoming its slow convergence by an acceleration technique, named random signed feedback, which shows an excellent performance, both in numerical simulation and tomographic experiment, of discriminating various polymers even when using 53 keV synchrotron X-rays.