Search NASA⌕ Search

Engineering topics

Vonrosenvinge, T. T.

Publications and source records attributed to Vonrosenvinge, T. T..

21 records · Page 2

The charge spectra of solar cosmic rays

An approach to measuring charged spectra of solar cosmic rays is considered. These observations were made by a telescope on the IMP 6 satellite. The charge range was extended beyond charge 2 up to charge 26, and the energy range was extended to lower energies. The experiment preferentially selects rare events above charge 2 and gives them top priority for telemetry readout, thus breaking the monopoly that protons and helium nuclei otherwise would have on the telemetry. This effectively increases the number of nuclei observed above charge 2 by a factor of several hundred.

Vonrosenvinge, T. T.↗

Satellite measurements of the charge composition of solar cosmic rays in the 6 less than or equal to Z less than or equal to 26 interval

The charge composition of solar cosmic rays were measured during two flares occurring in April and September 1971. The results were derived from a solid state dE/dx vs E telescope which was part of the cosmic ray experiment on the IMP 6 spacecraft. The data suggest that the helium to medium ratio may be varying from one flare to the next. The abundance ratios (normalized to oxygen) are compared with measurements of other investigators and significant disagreements are found. In particular, the data do not exhibit any systematic enhancement of heavy nuclei with respect to the spectroscopic abundances such as previously reported. Finally, the results are compared with the spectroscopically determined coronal and photospheric values, and again several important differences between the two sets of data are found.

Teegarden, B. J.↗

Solar proton, helium, and medium nuclei (Z is equal to or greater than 6 and equal to or less than 9) observed from the IMP-6 satellite

Proton, helium, and medium nuclei energy spectra have been measured from the Explorer 35 satellite for a recent solar flare. Above 2 MeV/nucleon these spectra are based upon single and dual parameter pulse height analysis in addition to threshold rate counting. Pulse height analysis of medium nuclei is assigned a high priority for telemetry readout so that telemetry does not become saturated by the high proton intensity. In this manner the number of pulse height analyzed medium nuclei has been increased by a factor of approximately 200. Individual medium nuclei have been resolved in the energy interval 8 - 23 MeV/nucleon.

Vonrosenvinge, T. T.↗