Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗