Waggoner, Charles A.

Publications and source records attributed to Waggoner, Charles A..

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Institute for Clean Energy Technology Mississippi State University NSR&D Aged HEPA Filter Study Final Report

Data have demonstrated that filter media lose tensile strength and the ability to resist the effects of moisture as a function of age. Testing of new and aged filters needs to be conducted to correlate reduction of physical strength of HEPA media to the ability of filters to withstand upset conditions. Appendix C of the Nuclear Air Cleaning Handbook provides the basis for DOE’s HEPA filter service life guidance. However, this appendix also points out the variability of data, and it does not correlate performance of aged filters to degradation of media due to age. Funding awarded by NSR&D to initiate full-scale testing of aged HEPA filters addresses the issue of correlating media degradation due to age with testing of new and aged HEPA filters under a generic design basis event set of conditions. This funding has accelerated the process of describing this study via: (1) establishment of a Technical Working Group of all stakeholders, (2) development and approval of a test plan, (3) development of testing and autopsy procedures, (4) acquiring an initial set of aged filters, (5) testing the initial set of aged filters, and (6) developing the filter test report content for each filter tested. This funding was very timely and has moved the project forward by at least three years. Activities have been correlated with testing conducted under DOE-EM funding for evaluating performance envelopes for AG-1 Section FC Separator and Separatorless filters. This coordination allows correlation of results from the NSR&D Aged Filter Study with results from testing new filters of the Separator and Separatorless Filter Study. DOE-EM efforts have identified approximately 100 more filters of various ages that have been stored under Level B conditions. NSR&D funded work allows a time for rigorous review among subject matter experts before moving forward with development of the testing matrix that will be used for additional filters. The NSR&D data sets are extremely valuable in as much as establishing a selfimproving, NQA-1 program capable of advancing the service lifetime study of HEPA filters. The data and reports are available for careful and critical review by subject matter experts before the next set of filters is tested and can be found in the appendices of this final report. NSR&D funds have not only initiated the Aged HEPA Filter Study alluded to in Appendix C of the NACH, but have also enhanced the technical integrity and effectiveness of all of the follow-on testing for this long-term study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating performance of high efficiency mist eliminators

Processing liquid wastes frequently generates off gas streams with high humidity and liquid aerosols. Droplet laden air streams can be produced from tank mixing or sparging and processes such as reforming or evaporative volume reduction. Unfortunately these wet air streams represent a genuine threat to HEPA filters. High efficiency mist eliminators (HEME) are one option for removal of liquid aerosols with high dissolved or suspended solids content. HEMEs have been used extensively in industrial applications, however they have not seen widespread use in the nuclear industry. Filtering efficiency data along with loading curves are not readily available for these units and data that exist are not easily translated to operational parameters in liquid waste treatment plants. A specialized test stand has been developed to evaluate the performance of HEME elements under use conditions of a US DOE facility. HEME elements were tested at three volumetric flow rates using aerosols produced from an iron-rich waste surrogate. The challenge aerosol included submicron particles produced from Laskin nozzles and super micron particles produced from a hollow cone spray nozzle. Test conditions included ambient temperature and relative humidities greater than 95%. Data collected during testing HEME elements from three different manufacturers included volumetric flow rate, differential temperature across the filter housing, downstream relative humidity, and differential pressure (dP) across the filter element. Filter challenge was discontinued at three intermediate dPs and the filter to allow determining filter efficiency using dioctyl phthalate and then with dry surrogate aerosols. Filtering efficiencies of the clean HEME, the clean HEME loaded with water, and the HEME at maximum dP were also collected using the two test aerosols. Results of the testing included differential pressure vs. time loading curves for the nine elements tested along with the mass of moisture and solid material on each element at final dP. Plots of overall filtering efficiencies for DOP (spherical aerosol) and dry surrogate (aspherical aerosols) at specified dPs were computed for each filter. Filtering efficiencies were determined as a function of particle size. Curves were also generated showing the most penetrating particle size as a function of dP. A preliminary set of tests was conducted to evaluate spray location, duration, pressure, and wash volume for in-place cleaning the interior surface (reducing dP) of the HEME element. A variety of nozzle designs were evaluated and test results demonstrated the potential to overload the HEME (saturate filter medium) resulting in very high dPs and extensive drain times. At least one combination of spray nozzle design, spray location on the surface of the element, and spray time/pressure was successful in achieving extension of operational life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Axial Flow AG-1 FC and Prototype FM (High Strength) HEPA Filters - 13123

High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilize a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM), New Mexico State University, and Mississippi State University. (authors)

42 ENGINEERING↗

Results from Evaluation of Representative ASME AG-1 Section FK Radial Flow Dimple Pleated HEPA Filters Under Elevated Conditions - 12002

The American Society of Mechanical Engineers (ASME) has recently added Section FK establishing requirements for radial flow HEPA filters to the Code on Nuclear Air and Gas Treatment (AG-1). Section FK filters are expected to be a major element in the HEPA filtration systems across the US Department of Energy (DOE) complex. Radial flow filters have been used in Europe for some time, however a limited amount of performance evaluation data exists with respect to these new AG-1 Section FK units. In consultation with a technical working group, the Institute for Clean Energy Technology (ICET) at Mississippi State University (MSU)has evaluated a series of representative AG-1 Section FK dimple pleated radial flow HEPA filters. The effects of elevated relative humidity and temperature conditions on these filters are particularly concerning. Results from the evaluation of Section FK filters under ambient conditions have been presented at the 2011 waste management conference. Additions to the previous test stand to enable high temperature and high humidity testing, a review of the equipment used, the steps taken to characterize the new additions, and the filter test results are presented in this study. Test filters were evaluated at a volumetric flow rate of 56.6 m{sup 3}/min (2000 cfm) and were challenged under ambient conditions with Alumina, Al(OH){sub 3}, until reaching a differential pressure of 1 kPa (4 in. w.c.), at which time the filters were tested, unchallenged with aerosol, at 54 deg. C (130 deg. F) for approximately 1 hour. At the end of that hour water was sprayed near the heat source to maximize vaporization exposing the filter to an elevated relative humidity up to 95%. Collected data include differential pressure, temperature, relative humidity, and volumetric flow rate versus time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficiency and Loading Evaluation of High Efficiency Mist Eliminators (HEME) - 12003

High efficiency mist eliminators (HEME) are filters primarily used to remove moisture and/or liquid aerosols from an air stream. HEME elements are designed to reduce aerosol and particulate load on primary High Efficiency Particulate Air (HEPA) filters and to have a liquid particle removal efficiency of approximately 99.5% for aerosols down to sub-micron size particulates. The investigation presented here evaluates the loading capacity of the element in the absence of a water spray cleaning system. The theory is that without the cleaning system, the HEME element will suffer rapid buildup of solid aerosols, greatly reducing the particle loading capacity. Evaluation consists of challenging the element with a waste surrogate dry aerosol and di-octyl phthalate (DOP) at varying intervals of differential pressure to examine the filtering efficiency of three different element designs at three different media velocities. Also, the elements are challenged with a liquid waste surrogate using Laskin nozzles and large dispersion nozzles. These tests allow the loading capacity of the unit to be determined and the effectiveness of washing down the interior of the elements to be evaluated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗