Acceptance Testing of the Scorpius Sweep Magnet

A beam-dump magnet for Scorpius has been defined by LANL and designed and built by Radiabeam Technologies. Initial verification of the Radiabeam design used a magnetic field model provided by Radiabeam and analyzed by LANL tools during September 2021. Simulations indicated that the design was sufficient to meet deflection requirements to protect sensitive equipment in the case of a failed target. In January 2022, the magnet was fabricated and Radiabeam conducted measurements of the magnetic field as a function of position. The measurements deviate somewhat from the simulation. In particular, the peak magnetic field is 10-15% smaller in magnitude than expected from simulation. This note compares the magnetic field measurements to simulation and to measurements of the existing DARHT magnet, which was designed for the same purpose. We show a comparison of the measured beam deflection performance between Scorpius and DARHT and show updated results of LANL’s electron beam tracking code using the Scorpius measurements. Using field measurements we find that the DARHT magnet will deflect a 19.6 MeV electron beam by 46.6° and the Scorpius magnet will deflect by 44.6°. These results show that the as-built Scorpius magnet has met design requirements for beam deflection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Estimation of the DARHT Radiographic Spot Size from Spatially Modulated Images

We wrote a software routine to find local extrema and calculate the contrast in the image for each feature set. The input is a KTO image in the standard DARHT orientation, pre-processed by flat-fielding, dark frame subtraction and de-warping. Table 1 shows contrast results for five contemporaneous DARHT images of the KTO. For some very dense feature sets, contrast measurements are not possible due to a lack of local extrema, and in this case no contrast value is given in the table. Highlighted in bold are the contrast values for each image that bound the threshold C = 0.01. The contrast is varying rapidly enough with spatial frequency that we can interpolate between these values to find an estimate of the spatial frequency at the threshold value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DARHT Radiographic Analysis of Spatially Modulated Objects

This document describes some analysis methods that can be performed using the Kaleidoscope test object (KTO) in order to assess DARHT radiography performance. The goal of these methods is to provide a simple metric of radiographic performance to compare different system configurations at DARHT. Specifically, these methods can be used to assess the Tiffany configurations to determine relative radiographic performance. To demonstrate the methods, we show results analysis performed on the ‘Tiffany A’ shot conducted in July 2021.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗