Search NASA⌕ Search

Engineering topics

Waldschmidt, G

Publications and source records attributed to Waldschmidt, G.

Higher Order Modes Damping Analysis for the SPX Deflecting Cavity Cyromodule

A single-cell superconducting deflecting cavity operating at 2.815 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source (APS) upgrade. A cryomodule of 4 such cavities will be needed to produce the required 2-MV deflecting voltage. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. The damping of the LOM/HOM below the beampipe cutoff has been analyzed in the single cavity geometry and shown to meet the design requirements. The HOM above the beampipe cutoff in the 4-cavity cyromodule, however, may result in cross coupling which may affect the HOM damping and potentially be trapped between the cavities which could produce RF heating to the beamline bellows. We have evaluated the HOM damping in the 4-cavity cryomodule using the parallel finite element EM code suite ACE3P developed at SLAC. We will present the results of the cryomodule analysis in this paper.

43 PARTICLE ACCELERATORS↗

Design and study of a high-current 5-cell superconducting rf cavity.

The Advanced Photon Source (APS) at Argonne National Laboratory is considering the development of a superconducting linac-based fourth-generation hard X-ray source to meet future scientific needs of the hard X-ray user community. This work specifically focuses on the design of an optimized 5-cell superconducting radio-frequency structure well suited for a high-energy, high-beam-current energy recovery linac. The cavity design parameters are based on the APS storage ring nominal 7 GeV and 100 mA beam operation. A high-current 5-cell cw superconducting cavity operating at 1.4 GHz has been designed. In order to achieve a high current, the accelerating cavity shape has been optimized and large end-cell beam pipes have been adopted. The beam break-up threshold of the cavity has been estimated using the code TDBBU, which predicts a high threshold beam current for a 7 GeV energy recovery linac model. A copper prototype cavity has been fabricated that uses half-cell modules, initially assembled by clamping the cells together.

43 PARTICLE ACCELERATORS↗

Superconducting accelerating structures for very low velocity ion beams.

This paper presents designs for four types of very-low-velocity superconducting (SC) accelerating cavity capable of providing several MV of accelerating potential per cavity, and suitable for particle velocities in the range 0.006<v/c<0.06. Superconducting TEM-class cavities have been widely applied to cw acceleration of ion beams. SC linacs can be formed as an array of independently phased cavities, enabling a variable velocity profile to maximize the output energy for each of a number of different ion species. Several laboratories in the U.S. and Europe are planning exotic beam facilities based on SC linacs. The cavity designs presented here are intended for the front end of such linacs, particularly for the postacceleration of rare isotopes of low charge state. Several types of SC cavities have been developed recently to cover particle velocities above 0.06c. Superconducting four-gap quarter-wave resonators for velocities 0.008<{beta}=v/c<0.05 were developed about two decades ago and have been successfully operated at the ATLAS SC linac at Argonne National Laboratory. Since that time, progress in simulation tools, cavity fabrication, and processing have increased SC cavity gradients by a factor of 3-4. This paper applies these tools to optimize the design of a four-gap quarter-wave resonator for exotic beam facilities and other low-velocity applications.

43 PARTICLE ACCELERATORS↗

Design and Performance of the LCLS Cavity BPM System

In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

36 MATERIALS SCIENCE↗

Thermo mechanical design of normal-conducting deflecting cavities at the Advanced Photon Source for short x-ray pulse generation.

A normal-conducting deflecting cavity is being designed at the Advanced Photon Source (APS) as a part of the short x-ray pulse project intended to provide users with approximately 2 picosecond x-rays. The system will use two pairs of 3-cell cavities in sectors 6ID and 7ID for the generation of the x-ray pulse in the 7ID beamline. The 3-cell cavities are designed to provide the desired beam deflection while absorbing in excess of 4 kW of power from a pulsed rf system and up to 2.6 kW in the damper system of high-order mode (HOM) and low-order mode (LOM) waveguides. Since the cavity frequency is very sensitive to thermal expansion, the cooling water system is designed so that it is able to control cavity temperature to within 0.1 C. This paper describes the optimization of the thermomechanical design of the cavity based on calculation of thermal stresses and displacement caused by the generated heat loads, and presents the design of a cooling water system required for the proper operation of the cavities.

43 PARTICLE ACCELERATORS↗

Electromagnetic design of the RF cavity beam position monitor for the LCLS.

A high-resolution X-band cavity BPM has been developed for the LCLS. A dipole mode cavity and a monopole mode reference cavity have been designed in order to achieve micron-level accuracy of the beam position. The rf properties of the BPM as well as beam interaction with the cavities will be discussed including output power and tuning. In addition, methods will be presented for improving the isolation of the output ports to differentiate between horizontal/vertical beam motion and to reject extraneous modes from affecting the output signal. The predicted simulation results will be compared to data collected from low-power experimental tests.

43 PARTICLE ACCELERATORS↗

The Advanced Photon Source pulsed deflecting cavity RF system.

The Advanced Photon Source Deflecting Cavity System for producing short X-ray pulses uses two multi-cell, S-band cavities to apply a deflecting voltage to the stored electron beam ahead of an undulator that supports a beamline utilizing picosecond X-rays. Two additional multi-cell cavities are then used to cancel out the perturbation and restore the electron beam to its nominal orbit. The pulsed rf system driving the deflecting cavities is described. Design tradeoffs are discussed with emphasis on topology considerations and digital control loops making use of sampling technology in a manner consistent with the present state of the art.

43 PARTICLE ACCELERATORS↗

High-power tests of a single-cell copper accelerating cavity driven by two input couplers.

High-power tests were conducted on a 350-MHz, single-cell copper accelerating cavity driven simultaneously by two H-loop input couplers for the purpose of determining the reliability, performance, and power-handling capability of the cavity and related components, which have routinely operated at 100-kW power levels. The test was carried out utilizing the APS 350-MHz RF Test Stand, which was modified to split the input rf power into two frac12-power feeds, each supplying power to a separate H-loop coupler on the cavity. Electromagnetic simulations of the two-coupler feed system were used to determine coupler match, peak cavity fields, and the effect of phasing errors between the coupler feed lines. The test was conducted up to a maximum total rf input power of 164-kW CW. Test apparatus details and performance data will be presented.

43 PARTICLE ACCELERATORS↗

Short x-ray pulse generation using deflecting cavities at the Advanced Photon Source.

Storage-ring-based third-generation light sources can provide intense radiation pulses with durations as short as 100 ps. However, there is growing interest within the synchrotron radiation user community in performing experiments with much shorter X-ray pulses. Zholents et al. [Nucl. Instr. and Meth. A 425 (1999) 385] recently proposed using RF orbit deflection to generate sub-ps X-ray pulses. In this scheme, two deflecting cavities are used to deliver a longitudinally dependent vertical kick to the beam. An optical slit can then be used to slice out a short part of the radiation pulse. Implementation of this scheme is planned for one APS beamline in the near future. In this paper, we summarize our feasibility study of this method and the expected X-ray beam parameters. We find that a pulse length of less than two picoseconds can be achieved.

43 PARTICLE ACCELERATORS↗

The Wakefield Effects of Pulsed Crab Cavities at the Advanced Photon Source for Short-X-ray Pulse Generation

In recent years we have explored the application to the Advanced Photon Source (APS) of Zholents' crab-cavity based scheme for production of short x-ray pulses. As a near-term project, the APS has elected to pursue a pulsed system using room-temperature cavities. The cavity design has been optimized to heavily damp parasitic modes while maintaining large shunt impedance for the deflecting dipole mode. We evaluated a system consisting of three crab cavities as an impedance source and determined their effect on the single- and multi-bunch instabilities. In the single-bunch instability we used the APS impedance model as the reference system in order to predict the overall performance of the ring when the crab cavities are installed in the future. For multi-bunch instabilities we used a realistic fill pattern, including hybrid-fill, and tracked multiple bunches where each bunch was treated as soft in distribution.

43 PARTICLE ACCELERATORS↗

Planned Use of Pulsed Crab Cavities for Short X-Ray Pulse Generation at the Advanced Photon Source

Recently, we have explored application to the Advanced Photon Source (APS) of Zholents'[1] crab cavity scheme for production of short x-ray pulses. We assumed use of superconducting (SC) cavities in order to have a continuous stream of crabbed bunches and flexibility of operating modes. The challenges of the SC approach are related to the size, cost, and development time of the cavities and associated systems. A good case can be made [2] for a pulsed system using room-temperature cavities. APS has elected to pursue such a system in the near term, with the SC-based system planned for a later date. This paper describes the motivation for the pulsed system and gives an overview of the planned implementation and issues. Among these are overall configuration options and constraints, cavity design options, frequency choice, cavity design challenges, tolerances, instabilities, and diagnostics plans.

43 PARTICLE ACCELERATORS↗