Pseudosymmetry in Tetragonal Perovskite SrIrO 3 Synthesized under High Pressure
Not Available
Engineering topics
Publications and source records attributed to Walker, David.
Not Available
Not provided.
Abstract Magnetic and electronic properties of quantum materials heavily rely on the crystal structure even in the same chemical compositions. In this study, it is demonstrated that a layered tetragonal EuCd 2 Sb 2 structure can be obtained by treating bulk trigonal EuCd 2 Sb 2 under high pressure (6 GPa) and high temperature (600 °C). Magnetization measurements of the newly formed layered tetragonal EuCd 2 Sb 2 confirm an antiferromagnetic ordering with Neel temperature ( T N ) around 16 K, which is significantly higher than that ( T N ≈ 7 K) of trigonal EuCd 2 Sb 2 , consistent with heat capacity measurements. Moreover, bad metal behavior is observed in the temperature dependence of the electrical resistivity and the resistivity shows a dramatic increase around the Neel temperature. Electronic structure calculations with local density approximation dynamic mean–field theory (LDA+DMFT) show that this material is strongly correlated with well‐formed large magnetic moments, due to Hund's coupling, which is known to dramatically suppress the Kondo scale.
Abstract Potassium dihydrogen phosphate (KDP) and its deuterated analog (DKDP) are unique nonlinear optical materials for high power laser systems. They are used widely for frequency conversion and polarization control by virtue of the ability to grow optical-quality crystals at apertures suitable for fusion-class laser systems. Existing methods for freeform figuring of KDP/DKDP optics do not produce surfaces with sufficient laser-induced–damage thresholds (LIDT’s) for operation in the ultraviolet portion of high-peak-power laser systems. In this work, we investigate fluid jet polishing (FJP) using a nonaqueous slurry as a sub-aperture finishing method for producing freeform KDP surfaces. This method was used to selectively polish surface areas to different depths on the same substrate with removals ranging from 0.16 μm to 5.13 μm. The finished surfaces demonstrated a slight increase in roughness as the removal depth increased along with a small number of fracture pits. Laser damage testing with 351 nm, 1 ns pulses demonstrated excellent surface damage thresholds, with the highest values in areas devoid of fracture pits. This work demonstrates, for the first time, a method that enables fabrication of a waveplate that provides tailored polarization randomization that can be scaled to meter-sized optics. Furthermore, this method is based on FJP technology that incorporates a nonaqueous slurry specially designed for use with KDP. This novel nonaqueous FJP process can be also used for figuring other types of materials that exhibit similar challenging inherent properties such as softness, brittleness, water-solubility, and temperature sensitivity.
Sr 2 IrO 4 with strong spin-orbit coupling (SOC) and Hubbard repulsion (U) hosts Mott insulating states. The similar crystal structure, magnetic and electronic properties, particularly the d-wave gap observed in Sr 2 IrO 4 enhanced the analogies to cuprate high-$T_c$ superconductor, La 2 CuO 4 . The incomplete analogy was due to the lack of broken inversion symmetry phases observed in Sr 2 IrO 4 . Here, under high pressure and high temperature conditions, we report a non-centrosymmetric Sr 2 IrO 4 . The crystal structure and its noncentrosymmetric character were determined by single crystal X-ray diffraction and high-resolution scanning transmission electron microscopy (HR-STEM). The magnetic characterization confirms the Ir 4+ with $\textit{S}$ = 1/2 at low temperature in Sr 2 IrO 4 with magnetic ordering occurred at around 86 K, where a larger moment is observed than the ambient pressure Sr 2 IrO 4 . Moreover, the resistivity measurement shows three-dimensional Mott variable-range hopping existed in the system. Further, this non-centrosymmetric Sr 2 IrO 4 phase appears to be a unique material to offer further understanding of high-$T_c$ superconductivity.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A new magnetic insulator Mn2MnSbO6 with a polar crystal structure and an ordered Mn2+ and Mn3+ arrangement was synthesized under a high pressure of 7.5 GPa and 1300 degrees C. The crystal structure of Mn2MnSbO6, investigated by synchrotron powder X-ray diffraction, was found to be isomorphous with that of Ni3TeO6-type, space group R3. The non-centrosymmetric structure was confirmed by the second-harmonic generation measurements. The X-ray absorption near-edge spectroscopy measurement confirmed the nominal oxidation states of Mn22+Mn3+SbO6. Magnetic measurements indicate that Mn2MnSbO6 orders antiferromagnetically below 44 K and undergoes a field-induced spin-flop transition at 5 K. First-principles calculations indicate an antiferromagnetic ground state with up/up/up/down/down/down (uuuddd) spin configuration of the six crystallographically unique Mn ions in the c-axis doubled magnetic structure. The density functional theory calculations also substantiate the experimentally observed charge ordering of the Mn2+/Mn3+ ions and the insulating behavior due to a bandgap of 0.52 eV. To the best of our knowledge, this is the first double corundum oxide containing Jahn-Teller active Mn3+ ions.
Not Available
The mineral Zlatogorite, CuNiSb 2 , was synthesized in the laboratory for the first time by annealing elements at ambient pressure (CuNiSb 2 -AP). Rietveld refinement of synchrotron powder X-ray diffraction data indicates that CuNiSb 2 -AP crystallizes in the NiAs-derived structure ( P 3 m 1, #164) with Cu and Ni ordering. The structure consists of alternate NiSb 6 and CuSb 6 octahedral layers via face-sharing. The formation of such structure instead of metal disordered NiAs-type structure ( P 6 3 / mm c, #194) is validated by the lower energy of the ordered phase by first-principle calculations. Interatomic crystal orbital Hamilton population, electron localization function, and charge density analysis reveal strong Ni-Sb, Cu-Sb, and Cu-Ni bonding and long weak Sb-Sb interactions in CuNiSb 2 -AP. The magnetic measurement indicates that CuNiSb 2 -AP is Pauli paramagnetic. First-principle calculations and experimental electrical resistivity measurements reveal that CuNiSb 2 -AP is a metal. The low Seebeck coefficient and large thermal conductivity suggest that CuNiSb 2 is not a potential thermoelectric material. Single crystals were grown by chemical vapor transport. The high pressure sample (CuNiSb 2 -8 GPa) was prepared by pressing CuNiSb 2 -AP at 700 °C and 8 GPa. However, the structures of single crystal and CuNiSb 2 -8 GPa are best fit with a disordered metal structure in the P 3 m 1 space group, corroborated by transmission electron microscopy.
Abstract This work describes a phase-resolving wave-forecasting algorithm that is based on the assimilation of marine radar image time series. The algorithm is tested against synthetic data and field observations. The algorithm couples X-band marine radar observations with a phase-resolving wave model that uses the linear mild slope equations for reconstruction of water surface elevations over a large domain of O (km) and a prescribed time window of O (min). The reconstruction also enables wave-by-wave forecasting through forward propagation in space and time. Marine radar image time series provide the input wave observations through a previously given relationship between backscatter intensity and the radial component of the sea surface slope. The algorithm assimilates the wave slope information into the model via a best-fit wave source function at the boundary that minimizes the slope reconstruction error over an annular region at the outer ranges of the radar images. The wave model is then able to propagate the waves across a polar domain to a location of interest at nearer ranges. The constraints on the method for achieving real-time forecasting are identified, and the algorithm is verified against synthetic data and tested using field observations.
We report a new polar and magnetic oxide, LuCrWO 6 , was synthesized under high pressure (6 GPa) and high temperature (1673 K). LuCrWO 6 is isostructural with the previously reported polar YCrWO 6 (SG: Pna21, no. 33). The ordering of CrO 6 and WO 6 octahedra in the edge-shared dimers induce the polar structure. The effective size of rare earth, Ln cation does not seem to affect the symmetry of LnCrWO 6 . Second harmonic generation measurements of LuCrWO 6 confirmed the noncentrosymmetric character and strong piezoelectric domains are observed from piezoresponse force microscopy at room temperature. LuCrWO 6 exhibits antiferromagnetic behavior, T N , of ~18 K with a Weiss temperature of -30.7 K.
Background (what): SI (International System of Units)-traceable Microwave Radiometer calibration; Motivation (why): NWP (Numerical Weather Prediction), FCDR (Fundamental Climate Data Record); Technology (how): NIST (National Inst. of Standards and Technology) blackbody target for ; Standards: Status & Future Plans. Development of a National Standard for Microwave Brightness Temperature (TB) at NIST.
A receiver gain modulation circuit (RGMC) was developed that modulates the power gain of the output of a radiometer receiver with a test signal. As the radiometer receiver switches between calibration noise references, the test signal is mixed with the calibrated noise and thus produces an ensemble set of measurements from which ensemble statistical analysis can be used to extract statistical information about the test signal. The RGMC is an enabling technology of the ensemble detector. As a key component for achieving ensemble detection and analysis, the RGMC has broad aeronautical and space applications. The RGMC can be used to test and develop new calibration algorithms, for example, to detect gain anomalies, and/or correct for slow drifts that affect climate-quality measurements over an accelerated time scale. A generalized approach to analyzing radiometer system designs yields a mathematical treatment of noise reference measurements in calibration algorithms. By treating the measurements from the different noise references as ensemble samples of the receiver state, i.e. receiver gain, a quantitative description of the non-stationary properties of the underlying receiver fluctuations can be derived. Excellent agreement has been obtained between model calculations and radiometric measurements. The mathematical formulation is equivalent to modulating the gain of a stable receiver with an externally generated signal and is the basis for ensemble detection and analysis (EDA). The concept of generating ensemble data sets using an ensemble detector is similar to the ensemble data sets generated as part of ensemble empirical mode decomposition (EEMD) with exception of a key distinguishing factor. EEMD adds noise to the signal under study whereas EDA mixes the signal with calibrated noise. It is mixing with calibrated noise that permits the measurement of temporal-functional variability of uncertainty in the underlying process. The RGMC permits the evaluation of EDA by modulating the receiver gain using an external signal. Without the RGMC, samples of calibrated references from radiometers form an ensemble data set of the natural occurring fluctuations within a receiver. By driving the gain of an otherwise stable receiver with an external signal, the conceptual framework and generalization of the mathematics of EDA can be tested. A series of measurements was conducted to evaluate and characterize the performance of the RGMC. Test signals stepped the RGMC across its dynamic range of performance using a radiometer that sampled four noise references; analysis indicates that the RGMC successfully modulated the receiver gain with an external signal. Calibration algorithms applied to four noise references demonstrate the RGMC produced ensemble data sets of the external signal.
The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.
This slide presentation reviews the use of ARTEMIS in the development and testing of the ARES launch vehicles. Ares Real Time Environment for Modeling, Simulation and Integration (ARTEMIS) is the real time simulation supporting Ares I hardware-in-the-loop (HWIL) testing. ARTEMIS accurately models all Ares/Orion/Ground subsystems which interact with Ares avionics components from pre-launch through orbit insertion The ARTEMIS System integration Lab, and the STIF architecture is reviewed. The functional components of ARTEMIS are outlined. An overview of the models and a block diagram is presented.