Search NASASearch

Engineering topics

Walker, H. E.

Publications and source records attributed to Walker, H. E..

Preliminary submillimeter spectroscopic measurements using a submillimeter heterodyne radiometer

A submillimeter heterodyne radiometer uses a submillimeter laser, pumped by a CO2 laser, as a local oscillator and a room temperature Schottky barrier diode as the first IF mixer. The radiometer can resolve spectral lines in the submillimeter region of the spectrum (arising from pure rotational molecular transitions) to within 0.3 MHz, using acousto-optic spectrum analyzer which measures the power spectrum by simultaneously sampling 0.3 MHz wide channels over a 100 MHz bandwidth spanning the line. Preliminary observations of eight spectral lines of H2O2, CO, NH3 and H2O, all lying in the 434-524 micrometer wavelength range are described. All eight lines were observed using two local oscillator frequencies obtained by operating the submillimeter laser with either methyl fluoride (CH3F) or formic acid (HCOOH) as the lasing gas. Sample calculations of line parameters from the observed data show good agreement with established values. One development goal is the size and weight reduction of the package to make it suitable for balloon or shuttle experiments to detect trace gases in the upper atmosphere.

Safren, H. G.

Laser tuners using circular piezoelectric benders

The paper presents the results of an experimental evaluation of a new type of piezoelectric ceramic device designed for use as a laser mirror tuner. Thin plates made from various materials were assembled into a circular bimorph configuration and tested for linearity of movement, maximum travel, and resonant frequency for varying conditions of clamping torque and mirror loading values. Most of the devices tested could accept mirror diameters up to approximately 1.3 cm and maintain a resonant frequency above 2 kHz. Typical mirror translation without measurable tilt was plus or minus 20 micrometers or greater for applied voltages of less than plus or minus 300 V.

Mcelroy, J. H.

Passively cooled glass CO2 laser tubes for severe environments

The objective of this effort was to design a glass CO2 laser tube that could survive the Titan 3 C launch environment and at the same time provide adequate thermal conductivity to maintain the wall of the laser tube below approximately equal to 50 C for efficient lasing. The approach that was taken to satisfy these requirements was to pot the tube in an aluminum heat sink using a space qualified polyurethane potting material. Two configurations of the laser tube successfully passed the complete Titan 3 C qualification level sine and random vibration specification and satisfied the thermal requirements. Fabrication details and test results are presented that indicate this could be a practical solution for laser tubes used in a severe environment and where flowing coolants are impractical or undesirable.

Walker, H. E.

Variable CO2 laser attenuator

An infrared wavelength variable attenuator based on contra-rotating germanium wedges is examined theoretically. The device redirects the paths of internal reflections associated with an optical flat to avoid closely spaced parallel beams at the output. Complementary wedges separated by an air gap compose an optical flat which, when combined with a masking arrangement, restricts unwanted reflections. A model of the device was built and experimentally evaluated. The results compare favorably with the dynamic range of attenuation of 2 to 50 db from theoretical calculations, and show a substantial reduction in the etalon effect associated with pairs of optical flats.

Klein, B. J.

A curve-fitting technique for the determination of gain and saturation intensity in homogeneously-broadened gas lasers: Application to a waveguide CO2 laser

A least squares curve-fitting algorithm is derived which allows the simultaneous estimation of the small signal gain and the saturation intensity from an arbitrary number of data points relating power output to the incidence angle of an internal coupling plate. The method is used to study the dependence of the two parameters on tube pressure and discharge current in a waveguide CO2 laser having a 2 mm diameter capillary. It is found that, at pressures greater than 28 torr, rising CO2 temperature degrades the small signal gain at current levels as low as three milliamperes.

Degnan, J. J.

Circular piezoelectric bender laser tuners

The circular piezoelectric bender laser tuner to replace conventional laser tuners when mirror diameters up to 0.50 inch are sufficient is described. The circular piezoelectric bender laser tuner offers much higher displacements per applied volt and permits laser control circuits to be fabricated using standard operational amplifiers, rather than the expensive high-voltage amplifiers required by conventional tuners. The cost of the device is more than one order of magnitude lower than conventional tuners and the device is very rugged with all mechanical resonances easily designed to be greater than 3kHz. In addition to its use as a laser frequency tuner, the circular bender tuner should find many applications in interferometers and similar devices.

Mcelroy, J. H.

The BAPE 2 balloon-borne CO2

The systems and techniques which were utilized in the experiment to establish an air-to-ground CO2 laser heterodyne link are described along with the successes and problems encountered when the heterodyne receiver and laser transmitter package were removed from the controlled environment of the laboratory. Major topics discussed include: existing systems and the underlying principles involved in their operation; experimental techniques and optical alignment methods which were found to be useful; theoretical calculations of signal strengths expected under a variety of test conditions and in actual flight; and the experimental results including problems encountered and their possible solutions.

Degnan, J. J.