Search NASA⌕ Search

Engineering topics

Walker, M L

Publications and source records attributed to Walker, M L.

KSTAR Equilibrium Operating Space and Projected Stabilization at High Normalized Beta

Along with an expanded evaluation of the equilibrium operating space of the Korea Superconducting Tokamak Advanced Research, KSTAR, experimental equilibria of the most recent plasma discharges were reconstructed using the EFIT code. In near-circular plasmas created in 2009, equilibria reached a stored energy of 54 kJ with a maximum plasma current of 0.34 MA. Highly shaped plasmas with near double-null configuration in 2010 achieved H-mode with clear edge localized mode (ELM) activity, and transiently reached a stored energy of up to 257 kJ, elongation of 1.96 and normalized beta of 1.3. The plasma current reached 0.7 MA. Projecting active and passive stabilization of global MHD instabilities for operation above the ideal no-wall beta limit using the designed control hardware was also considered. Kinetic modification of the ideal MHD n = 1 stability criterion was computed by the MISK code on KSTAR theoretical equilibria with a plasma current of 2 MA, internal inductance of 0.7 and normalized beta of 4.0 with simple density, temperature and rotation profiles. The steep edge pressure gradient of this equilibrium resulted in the need for significant plasma toroidal rotation to allow thermal particle kinetic resonances to stabilize the resistive wall mode (RWM). The impact of various materials and electrical connections of the passive stabilizing plates on RWM growth rates was analysed, and copper plates reduced the RWM passive growth rate by a factor of 15 compared with stainless steel plates at a normalized beta of 4.4. Computations of active RWM control using the VALEN code showed that the n = 1 mode can be stabilized at normalized beta near the ideal wall limit via control fields produced by the midplane in-vessel control coils (IVCCs) with as low as 0.83kW control power using ideal control system assumptions. The ELM mitigation potential of the IVCC, examined by evaluating the vacuum island overlap created by resonant magnetic perturbations, was analysed using the TRIP3D code. Using a combination of all IVCCs with dominant n = 2 field and upper/lower coils in an even parity configuration, a Chirikov parameter near unity at normalized poloidal flux 0.83, an empirically determined condition for ELM mitigation in DIII-D, was generated in theoretical high-beta equilibria. Chirikov profile optimization was addressed in terms of coil parity and safety factor profile.

Park, Y S↗

Solenoid-free startup experiments in DIII-D

A series of DIII-D experiments was performed to investigate the potential for initiating plasma current using only poloidal field coils located outside the DIII-D central solenoid, i.e. 'solenoid-free'. Plasma current to 166 kA was achieved using 2-3MW of electron cyclotron (EC) heating and was limited by coil and power supply constraints. Flux conversion to plasma current was similar to standard DIII-D startup with some degradation at higher plasma current associated with stray fields and vertical stability issues. In preliminary solenoid-free experiments, neutral beam (NB) current drive (CD) levels were small and attributed to reduced CD efficiency associated with low electron temperature produced by the low current, low confinement plasma. Lack of plasma radial position control also contributed to a reduction of NBCD. Similarly, ECCD was small owing to low plasma temperature and outside EC launch which is required in the solenoid-free scenario. Synergistic experiments were carried out using standard solenoid initiated plasmas in order to study noninductive CD in limited, Lmode plasmas, typical of that generated by solenoid-free startup. While substantial noninductive current can be driven, self-sustaining levels of noninductive current have not yet been achieved with our present six-source co-injection NB system combined with EC and fast wave systems. At low plasma current and high levels of localized EC heating, substantial MHD is generated and this was seen to severely limit plasma performance. Although further optimization is possible in the limited plasma regime, full noninductive, steady-state operation may require diverted plasma with H-mode quality confinement. Discharges obtained during the solenoid-free campaign are compared with results of previous DIII-D campaigns aimed at achieving a steady state, noninductive CD solution.

FACILITY↗

ECH-assisted startup at KSTAR

The electron cyclotron heating (ECH)-assisted startup was successful in the Korea Superconducting Tokamak Advanced Research (KSTAR) first plasma campaign completed in June, 2008. It was observed that the second harmonic EC wave of 0.35 MW was sufficient to achieve breakdown in the ECH pre-ionization phase, to allow burn through, and to sustain the plasma during the current ramp with a low loop voltage of 2.0 V. This corresponds to a toroidal electric field of 0.24 Vm{sup -1} at the innermost vacuum vessel wall (R = 1.3 m). Since there is no feedback control of the plasma radial position in the initial phase of the KSTAR first plasma campaign, wall contact caused the plasma current fall to zero soon after the ECH beam was turned off. Extending pulse duration of the ECH power to 190 ms allowed the plasma current to rise up to more than 100 kA with a ramp-up rate of 0.8 MA/s and the pulse duration of 210 ms. Later in the first plasma campaign, the plasma was sustained up to 865 ms with the help of additional heating of 350-ms long ECH beam and with the help of the plasma radial position feedback control. The plasma current in the pre-ionization phase was observed and it is considered to be pressure-driven Pfirsch-Schlueter current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ventricular dilation and elevated aqueductal pulsations in a new experimental model of communicating hydrocephalus

In communicating hydrocephalus (CH), explanations for the symptoms and clear-cut effective treatments remain elusive. Pulsatile flow through the cerebral aqueduct is often significantly elevated, but a clear link between abnormal pulsations and ventriculomegaly has yet to be identified. We sought to demonstrate measurement of pulsatile aqueductal flow of CSF in the rat, and to characterize the temporal changes in CSF pulsations in a new model of CH. Hydrocephalus was induced by injection of kaolin into the basal cisterns of adult rats (n = 18). Ventricular volume and aqueductal pulsations were measured on a 9.4 T MRI over a one month period. Half of the animals developed ventricular dilation, with increased ventricular volume and pulsations as early as one day post-induction, and marked chronic elevations compared to intact controls (volume: 130.15 {+-} 83.21 {mu}l vs. 15.52 {+-} 2.00 {mu}l; pulsations: 114.51 nl {+-} 106.29 vs. 0.72 {+-} 0.13 nl). Similar to the clinical presentation, the relationship between ventricular size and pulsations was quite variable. However, the pulsation time-course revealed two distinct sub-types of hydrocephalic animals: those with markedly elevated pulsations which persisted over time, and those with mildly elevated pulsations which returned to near normal levels after one week. These groups were associated with severe and mild ventriculomegaly respectively. Thus, aqueductal flow can be measured in the rat using high-field MRI and basal cistern-induced CH is associated with an immediate change in CSF pulsatility. At the same time, our results highlight the complex nature of aqueductal pulsation and its relationship to ventricular dilation.

60 APPLIED LIFE SCIENCES↗