Search NASASearch

Engineering topics

Walker, R. E.

Publications and source records attributed to Walker, R. E..

Army technology development. IBIS query. Software to support the Image Based Information System (IBIS) expansion for mapping, charting and geodesy

The Image Based Information System (IBIS) has been under development at the Jet Propulsion Laboratory (JPL) since 1975. It is a collection of more than 90 programs that enable processing of image, graphical, tabular data for spatial analysis. IBIS can be utilized to create comprehensive geographic data bases. From these data, an analyst can study various attributes describing characteristics of a given study area. Even complex combinations of disparate data types can be synthesized to obtain a new perspective on spatial phenomena. In 1984, new query software was developed enabling direct Boolean queries of IBIS data bases through the submission of easily understood expressions. An improved syntax methodology, a data dictionary, and display software simplified the analysts' tasks associated with building, executing, and subsequently displaying the results of a query. The primary purpose of this report is to describe the features and capabilities of the new query software. A secondary purpose of this report is to compare this new query software to the query software developed previously (Friedman, 1982). With respect to this topic, the relative merits and drawbacks of both approaches are covered.

Friedman, S. Z.

An analysis of Landsat Thematic Mapper P-Product internal geometry and conformity to earth surface geometry

Performance requirements regarding geometric accuracy have been defined in terms of end product goals, but until recently no precise details have been given concerning the conditions under which that accuracy is to be achieved. In order to achieve higher spatial and spectral resolutions, the Thematic Mapper (TM) sensor was designed to image in both forward and reverse mirror sweeps in two separate focal planes. Both hardware and software have been augmented and changed during the course of the Landsat TM developments to achieve improved geometric accuracy. An investigation has been conducted to determine if the TM meets the National Map Accuracy Standards for geometric accuracy at larger scales. It was found that TM imagery, in terms of geometry, has come close to, and in some cases exceeded, its stringent specifications.

Bryant, N. A.

Landsat Thematic Mapper geodetic accuracy - Implications for geocoded map compatibility

The geodetic accuracy and geometric fidelity of corrected thematic mapper (TM) imagery are evaluated. The positional accuracy requirements for the TM are for a single band to within 0.5 pixels of true earth-surface locations at any point over 90 percent of the image and for interband registration to within 0.3 pixel tolerance over 90 percent of the data. Landsat 4 and 5 TM data are analyzed to investigate: (1) single band geometric integrity, (2) 30 m resolution interband registration; (3) image to image conformity; (4) image to ground conformity; and (5) image projective geometry conformity to a mapped earth geometry. The procedures used to study these characteristics are described. The data reveal that Landsat TM digital data met or exceed map accuracy standards for horizontal control.

Bryant, N. A.

The geometric properties of Landsat-5 Thematic Mapper data and their conformity to Landsat-4 data and to earth's surface geometry

The geometry of two TIPS processed Landsat-5 Thematic Mapper scenes was analyzed and compared with that of SCROUNGE processed Landsat-4 data. Swath-to-swath and band-to-band registration of Washington, DC, and northeastern Iowa scenes was found to be similar to or better than that of Landsat-4 data. Results indicate a high degree of geometric conformity between the images produced by the different systems. The geometric conformity of the TIPS processed images to the Space Oblique Mercator projection, however, proved to be less accurate than the targeted processing error of 15 meters.

Walker, R. E.

An Analysis LANDSAT-4 Thematic Mapper Geometric Properties

LANDSAT Thematic Mapper P-data of Washington, D. C., Harrisburg, PA, and Salton Sea, CA are analyzed to determine magnitudes and causes of error in the geometric conformity of the data to known Earth surface geometry. Several tests of data geometry are performed. Intraband and interband correlation and registration are investigated, exclusive of map based ground truth. The magnitudes and statistical trends of pixel offsets between a single band's mirror scans (due to processing procedures) are computed, and the inter-band integrity of registration is analyzed. A line to line correlation analysis is included.

Walker, R. E.

An analysis of Landsat-4 Thematic Mapper geometric properties

Landsat-4 Thematic Mapper data of Washington, DC, Harrisburg, PA, and Salton Sea, CA were analyzed to determine geometric integrity and conformity of the data to known earth surface geometry. Several tests were performed. Intraband correlation and interband registration were investigated. No problems were observed in the intraband analysis, and aside from indications of slight misregistration between bands of the primary versus bands of the secondary focal planes, interband registration was well within the specified tolerances. A substantial number of ground control points were found and used to check the images' conformity to the Space Oblique Mercator (SOM) projection of their respective areas. The means of the residual offsets, which included nonprocessing related measurement errors, were close to the one pixel level in the two scenes examined. The Harrisburg scene residual mean was 28.38 m (0.95 pixels) with a standard deviation of 19.82 m (0.66 pixels), while the mean and standard deviation for the Salton Sea scene were 40.46 (1.35 pixels) and 30.57 m (1.02 pixels), respectively. Overall, the data were judged to be a high geometric quality with errors close to those targeted by the TM sensor design specifications.

Walker, R. E.

Thermal protection of reentry vehicles by actively cooled nosetips

Analytical modeling efforts and clear-air ground test results of a transportation-cooled nosetips (TCNT) design are presented. The discrete water injection platelet TCNT described was conceived and created to achieve the performance requirements for severe reentry vehicle trajectories. Thermal performance computer modeling techniques, combing both local heat blockage and boundary layer recovery enthalpy reduction are outlined.

Walker, R. E.

An Empirical Model for the Mixing of a Row of Dilution Jets with a Confined Crossflow

An empirical model was developed for predicting the temperature distribution downstream from a row of cool jets injected normally into a hot confined crossflow. The model is based on the assumption that all properly non-dimensionalized vertical temperature profiles can be expressed in a self-similar form. The scaling parameters in this form were correlated in terms of the independent flow and geometric variables. The effect of parametric variation of each of the independent variables on the experimental and predicted profiles are examined. The predicted distributions show excellent agreement with the data over a wide range of the independent variables.

Holdeman, J. D.

An empirical model for the mixing of a row of dilution jets with a confined crossflow

An empirical model has been developed for predicting the temperature distribution downstream of a row of cool jets injected normal to a hot confined crossflow. The model is based on the assumption that all properly non-dimensionalized vertical temperature profiles can be expressed in a self-similar form. The scaling parameters in this form have been correlated in terms of the independent flow and geometric variables. The effect of parametric variation of each of the independent variables on the experimental and predicted profiles are examined. The predicted distributions show excellent agreement with the data over a wide range of the independent variables.

Holdeman, J. D.

Investigations of multiple jets in a crossflow

Study was conducted to determine penetration and mixing characteristics of multiple jets of ambient temperature air injected perpendicularly into ducted mainstream of hot combustion gases.

Walker, R. E.

Multiple jet study data correlations

Correlations are presented which allow determination of penetration and mixing of multiple cold air jets injected normal to a ducted subsonic heated primary air stream. Correlations were obtained over jet-to-primary stream momentum flux ratios of 6 to 60 for locations from 1 to 30 jet diameters downstream of the injection plane. The range of geometric and operating variables makes the correlations relevant to gas turbine combustors. Correlations were obtained for the mixing efficiency between jets and primary stream using an energy exchange parameter. Also jet centerplane velocity and temperature trajectories were correlated and centerplane dimensionless temperature distributions defined. An assumption of a Gaussian vertical temperature distribution at all stations is shown to result in a reasonable temperature field model. Data are presented which allow comparison of predicted and measured values over the range of conditions specified above.

Walker, R. E.

Mixing of multiple dilution jets with a hot primary airstream for gas turbine combustors

The mixing of multiple air jets with a subsonic heated crossflow in a constant area duct was studied experimentally. The jet-to-mainstream momentum flux ratio was varied from 6 to 60. Temperature and pressure surveys were made at several downstream locations for orifice geometries with parametric variation of orifice size and spacing. A mixing efficiency parameter was defined which characterized the effectiveness of the mixing over the range of conditions examined. It was found that for a given momentum flux ratio, there exists a ratio of orifice spacing to duct height which provides the best mixing.

Holdeman, J. D.

Multiple jet study

Test data is presented which allows determination of jet penetration and mixing of multiple cold air jets into a ducted subsonic heated mainstream flow. Jet-to-mainstream momentum flux ratios ranged from 6 to 60. Temperature profile data is presented at various duct locations up to 24 orifice diameters downstream of the plane of jet injection. Except for two configurations, all geometries investigated had a single row of constant diameter orifices located transverse to the main flow direction. Orifice size and spacing between orifices were varied. Both of these were found to have a significant effect on jet penetration and mixing. The best mixing of the hot and cold streams was achieved with duct height.

Walker, R. E.