Search NASA⌕ Search

Engineering topics

Wallace, M. S.

Publications and source records attributed to Wallace, M. S..

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Development of improved higher-order correction for the NIF opacity spectrometer

X-ray opacity measurements on the National Ignition Facility (NIF) are in the process of reproducing earlier measurements from the Sandia Z Facility, in particular for oxygen and iron plasmas. These measurements have the potential to revise our understanding of the “solar problem” and of the hot degenerate Q class white dwarf structure by probing plasma conditions near the base of their convection zones. Accurate opacity measurements using soft x-ray Bragg crystal spectrometers require correction for higher-order diffraction effects. Extending prior work in this area [Dutra et al., Review of Scientific Instruments 93, 113527 (2022)], we have developed a new method to remove higher-order spectral components from NIF opacity spectrometer data. Furthermore, by modeling absorption and backlighting continuum spectra and subtracting the second- and third-order components from the measured data, we are able to perform this correction while avoiding imprinting first-order model line features onto the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign

A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. Here, the spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ~2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ~1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Opacity Program - Tri-Lab Assessment of Measurements and Models (Milestone 7720)

Opacity-on-NIF has obtained opacity data under conditions similar to those achieved by the entirely different Opacity-on-Z platform. From low- and high-Z elements at different anchor points, rigorously compare the opacity data between the laboratories and to multiple opacity theory models. Compare and assess the data acquisition and processing methods for obtaining opacities and for measuring/inferring sample conditions. Explain, or develop hypotheses for, any discrepancies. Map progress to the National Opacity Strategy and define future directions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Milestone 7720: National Opacity Program - Tri-Lab Assessment of Measurements and Models

Opacity-on-NIF has obtained opacity data under conditions similar to those achieved by the entirely different Opacity-on-Z platform. From low- and high-Z elements at different anchor points, rigorously compare the opacity data between the laboratories and to multiple opacity theory models. Compare and assess the data acquisition and processing methods for obtaining opacities and for measuring/inferring sample conditions. Explain, or develop hypotheses for, any discrepancies. Map progress to the National Opacity Strategy and define future directions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

Milestone 7714 National Opacity Program: High-Fidelity Iron Data on NIF

Establish the level of reproducibility of NIF iron opacity shots, quantify to-date improvements in data quality through, e.g. background reduction, improved signal, and improved analysis methods, and formalize the approach that will be taken in the future to compare NIF data, Z data, and theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Polarization splitting with cubic crystals evaluated with synchrotron radiation

X-ray polarization-splitting crystals separate incident x rays into two components with perpendicular polarization by Bragg reflections at 45° from paired sets of internal planes. Here, the polarization-splitting properties of a germanium crystal are verified using incompletely polarized synchrotron radiation. Further, cleaner data would have come from a beam with a higher degree of polarization, which is achievable with small changes in the experimental geometry.

47 OTHER INSTRUMENTATION↗

Cubic crystals in an x-ray polarization-splitting geometry

Hexagonal and cubic crystals contain paired sets of internal planes that reflect the linearly polarized components of certain x rays into two separate, perpendicular directions. For the cubic crystals, two distinct crystal orientations provide the same polarization-splitting geometry. One of the orientations may have advantages for plasma spectroscopy by suppressing unwanted reflections. This paper demonstrates the two orientations with a germanium crystal and K characteristic lines from copper and zirconium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗