Selective solid-state isolation of NMR circuit elements using back-to-back field effect transistors

Nuclear Magnetic Resonance (NMR) electronics that employ selective solid-state isolation of circuit elements can include solid-state switches, such as back-to-back Field Effect Transistor (FET) pairs, and isolated gate drive electronics adapted to operate the solid-state switches in order to selectively decouple induction coils from receive electronics. The solid-state switches can be placed in series to achieve higher standoff voltages, and can be configured for low on resistance and short switching times. The gate drive electronics can include electrical isolation components adapted to enhance standoff voltages and reduce electrical noise at the selectively isolated receive electronics.

Walsh, David O.↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Relaxation time estimation in surface NMR

Technologies including NMR relaxation time estimation methods and corresponding apparatus are disclosed. Example techniques may include performing at least one single-pulse acquisition sequence, the single-pulse acquisition sequence comprising transmitting a single modulated pulse with a surface coil, wherein the phase, frequency, or amplitude of the single modulated pulse is varied during the single modulated pulse, and wherein the single modulated pulse excites a transverse magnetization component within a subsurface fluid. The resulting NMR signal may be recorded on at least one receiving device, including recording the NMR signal associated with the transverse magnetization component excited by the single modulated pulse. Processing techniques may be applied in which recorded NMR response data are used to estimate NMR properties and the relaxation times T1 and T2* as a function of position as well as one-dimensional and two-dimension distributions of T1 versus T2* as a function of subsurface position.

58 GEOSCIENCES↗