Search NASA⌕ Search

Engineering topics

Walworth, Matthew J

Publications and source records attributed to Walworth, Matthew J.

HPTLC Plate Blotting for Liquid Microjunction Surface Sampling Probe Mass Spectrometric Analysis of Analytes Separated on a Wettable Phase Plate

A blotting method that transfers analytes separated on wettable HPTLC plates to a hydrophobic reversed-phase C8 HPLTC plate suitable for analysis with a liquid microjunction surface sampling probe electrospray ionization mass spectrometry system was described and demonstrated. The simple blotting procedure transfers the analyte from the wettable plate to the topmost surface of a rigidly backed, easy-to-mount hydrophobic substrate that already has been proven viable for analysis by this sampling probe/mass spectrometry system. The utility of the approach was demonstrated by the analysis of a four-component peptide mixture originally separated on a ProteoChrom HPTLC cellulose sheet and then blotted to the reversed phase HPTLC plate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Sampling and Analysis from Solid Phase Extraction Cards using an Automated Liquid Extraction Surface Analysis Nanoelectrospray Mass Spectrometry System

Direct liquid extraction based surface sampling, a technique previously demonstrated with continuous flow and autonomous pipette liquid microjunction surface sampling probes, has recently been implemented as the Liquid Extraction Surface Analysis (LESA) mode on the commercially available Advion NanoMate chip-based infusion nanoelectrospray ionization system. In the present paper, the LESA mode was applied to the analysis of 96-well format custom solid phase extraction (SPE) cards, with each well consisting of either a 1 or 2 mm diameter monolithic hydrophobic stationary phase. These substrate wells were conditioned, loaded with either single or multi-component aqueous mixtures, and read out using the LESA mode of a TriVersa NanoMate or a Nanomate 100 coupled to an ABI/Sciex 4000QTRAPTM hybrid triple quadrupole/linear ion trap mass spectrometer and a Thermo LTQ XL linear ion trap mass spectrometer. Extraction conditions, including extraction/nanoESI solvent composition, volume, and dwell times, were optimized in the analysis of targeted compounds. Limit of detection and quantitation as well as analysis reproducibility figures of merit were measured. Calibration data was obtained for propranolol using a deuterated internal standard which demonstrated linearity and reproducibility. A 10x increase in signal and cleanup of micromolar Angiotensin II from a concentrated salt solution was demonstrated. Additionally, a multicomponent herbicide mixture at ppb concentration levels was analyzed using MS3 spectra for compound identification in the presence of isobaric interferences.

Direct liquid extraction↗

Hydrophobic Treatment Enabling Analysis of Wettable Surfaces using a Liquid Microjunction Surface Sampling Probe/Electrospray Ionization-Mass Spectrometry System

An aerosol application procedure involving one or more commercially available silicone based products was developed to create hydrophobic surfaces that enable analysis of otherwise wettable, absorbent surfaces using a liquid microjunction surface sampling probe/electrospray ionization mass spectrometry system. The treatment process resulted in a hydrophobic surface that enabled formation of the requisite probe - to - surface liquid microjunction for sampling and allowed efficient extraction of the analytes from the surface, but did not contribute significant chemical background in the mass spectra. The utility of this treatment process was demonstrated with the treatment of wettable high performance thin layer chromatography plates, post plate development, and their subsequent analysis with the sampling probe. The surface treatment process for different surface types was described and explained and the effectiveness of the treatment and subsequent analysis was illustrated using alkaloids from Goldenseal (Hydrastis canadensis) root separated on a normal phase silica gel 60 F254S plate and peptides from protein tryptic digests separated on a Protochrom HPTLC Silica gel 60 F254S plate and a Protochrom HPTLC cellulose sheet. This simple surface treatment process significantly expands the analytical surfaces that can be analyzed with the liquid microjunction surface sampling probe, and therefore, also expands the analytical utility of this liquid extraction based surface sampling approach.

Walworth, Matthew J↗