Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Parameter extraction approaches for compact modeling of thermoelectric modules

Thermoelectric (TE) cooling has experienced rapid advancements with the foundational understanding of TE materials. TE modules, compact and lightweight devices, have become the prevalent approach for implementing TE technologies. Accurately quantifying TE physical parameters (Seebeck coefficient α, thermal conductivity κ, and thermal resistance ρ) is challenging due to the dynamic temperature changes in operation. Furthermore, extracting lumped property parameters is crucial for designing energy systems using TE modules. Existing research has several limitations, such as lack of comparative analysis between prevalent formulae, reliance on potentially inaccurate vendor-supplied data, disregard for fundamental assumptions, and absence of empirical measurements. Further, this study addresses these gaps by conducting TE material characterization, comparing three existing formulae using vendor datasheets, designing a laboratory test facility for model validation and refinement, and outlining a structured data extraction procedure. The study's novelty lies in multiple key contributions: (1) a detailed comparative analysis of existing formulae for extracting TE property parameter; (2) executing experimental work in a laboratory setting to validate the model and elucidate its limitations; (3) highlighting potential risks; (4) clarifying possible assumptions from both material and engineering perspectives; and (5) considering temperature differential impacts. This comprehensive approach addresses the current research gaps and provides valuable insights into the design and application of TE modules in various energy systems.

36 MATERIALS SCIENCE↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗

A thermodynamic model of integrated liquid-to-liquid thermoelectric heat pump systems

Thermoelectric (TE) heat pumps (TEHPs) are advantageous for heating and cooling in various applications because of their modularity and simple design. A TEHP system includes the TE modules with p- and n-type materials bonded to substrates, plus heat exchangers, thermal interfaces to the heat exchangers, and heat transfer fluids. Although modeling an individual TE module has been extensively studied, limited studies have reported performance at the larger system-level. Furthermore, no prior study has addressed the impact of temperature-dependent TE material properties (e.g., electric resistivity, thermal conductivity, and Seebeck coefficient) on overall heat-pump-system-level performance. Here, this work presents a mathematical model for TEHP system performance based on Goldsmid's approach for TE material performance, “effective” TE material properties, Gnielinski's correlation for convective heat transfer, and thermal balance theory for a heat exchange network. This combined approach provides an accurate model of the liquid-to-liquid TEHP system. Three different approaches—one empirical, one based on the manufacturer's specifications, and one drawn from the literature—were then used to determine values for TE material properties. The first two methods treated properties as constants, while the last approach treated properties as surface-temperature-based functions. Finally, experimental TEHP data was used to validate the models, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–25% when forecasting cooling capacity up to a 30 K surface temperature lift. The results demonstrated that, at the TEHP system level, the TE material properties could be treated as constants, avoiding solver iterations and reducing the performance uncertainty by up to 95%.

42 ENGINEERING↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗