Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Demonstration of an 850 V dc to 13.8 kV ac 100 kW Three-phase Four-wire Power Conditioning System Converter Using 10 kV SiC MOSFETs

In this paper, an 850 V dc to 13.8 kV ac 100 kW modular multilevel three-phase four-wire dc/ac converter based on 10 kV SiC MOSFETs is designed and demonstrated. The design considerations of key components, including the dc-link, device cooling, gate driver, isolated gate driver power supply (GDPS), medium voltage (MV) ac filter inductor, MV and medium frequency transformer, and the mechanical design are discussed. Two converters are designed, and two prototypes are developed, to study the converter paralleling operation and scalability. Both converters are fully tested up to their voltage and power ratings. However, the two converters are not identical. Based on the design and test results of the first converter, the MV power stage, transformer design, GDPS, as well as the low voltage power stage in the second converter are improved for smaller size and/or higher efficiency. Compared to the version 1 converter, the version 2 converter achieves 49% volume reduction and 2 percentage point efficiency improvement, with a peak efficiency of 98.4% at the rated power.

Li, Haiguo↗

A Flux Balancing Strategy for 10-kV SiC-Based Dual-Active-Bridge Converter

The transformer flux unbalance in dual-active-bridge (DAB) converters is a critical issue due to the electrical parameter and modulation mismatch, and load or control transients. Compared to low voltage DAB converters, the unbalance problem in medium voltage DAB converters may cause more severe problem, and become more difficult to deal with, because of the high operating voltage and insulation requirement. In this paper, a flux balancing strategy for a medium voltage (MV) DAB converter is proposed, including the transformer design with ferrite gap, current harmonic-based unbalance detection, as well as the flux balancing control scheme. With the proposed ferrite gap, nonlinear magnetizing current and its modeling are induced. Then, by analyzing the current harmonics, the flux unbalance level can be detected, and hence controlled. Test results have verified the proposed method in a MV DAB converter.

Gao, Zihan↗

A PWM Strategy for Cascaded H-bridges to Reduce the Loss Caused by Parasitic Capacitances of Medium Voltage Dual Active Bridge Transformers

In this paper, to reduce the power loss caused by the parasitic capacitances of medium voltage medium frequency transformers in a two-stage dc/ac converter, including a dual active bridge (DAB)-based dc/dc stage and a cascaded H-bridge (CHB)-based dc/ac stage, a PWM strategy is proposed for the dc/ac stage. For each H-bridge, by shifting the high switching frequency to one half-bridge and having the other half-bridge switching at the fundamental frequency of the ac voltage, equivalent frequencies of transformer terminal-to-ground voltages are reduced. As a result, the frequencies of charging and discharging current to the parasitic capacitance are reduced, and therefore the loss caused by the parasitic capacitances is reduced. Compared to the conventional phase-shift PWM, the proposed PWM strategy can reduce the parasitic capacitance loss by about 75%. Experimental test results of one phase in the 13.8 kV/ 100 kW converter prototype are provided to validate the approach.

Li, Haiguo↗

A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller (Final Report)

This report contains information regarding the activities carried out in the project "A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller. The project aims at developing a community-based flexible microgrid (FMG) with smart grid features, including multiple utility feeders and dynamic boundaries that utilize intelligent switches and ultra-high-speed communication links already in a smart grid. The project also aims at developing a corresponding controller for such an FMG with low cost and high scalability. With distributed renewable energy resources (DERs) and the intelligent microgrid controller, the FMG will achieve aggressive emission reduction, increased energy use efficiency, and reliability improvement goals. The FMG and its controller design will be scalable for different geographic areas, load sizes, distributed generation source number and types, and even multiple MGs within a distribution electric power system. In order to achieve these project objectives, three main development tasks were carried out: FMG design, FMG controller development, and FMG controller testing. The fourth task was technology to market.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

Development of a Power Electronics-based Testbed for a Flexible Combined Heat and Power System

A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗

An Inrush Current Limit Method for SiC-based Multi-level Grid-connected Converter During Low-Voltage Ride-Through

Low-voltage ride-through is one of the grid requirements for grid-connected converters, and during the transient of grid voltage change, a large inrush current could be induced due to the control delay of the converter. This inrush current is more severe in SiC-based multi-level converters due to the small filter inductance, which is selected based on harmonics consideration. In this paper, a PWM mask method is used to limit the inrush current of a cascaded H-bridge-based grid-connected converter during the transient of grid voltage change. Simulation and experiment results are provided to validate this method.

Li, Haiguo↗