Search NASA⌕ Search

Engineering topics

Wang, G

Publications and source records attributed to Wang, G.

At least 109 records · Page 6

Control of membrane thermal transport supporting superconducting detetctor development.

Because thermal transport determines the dynamic and static operation of bolometric detectors, control of the thermal conductance is critical for the implementation of detectors utilizing superconducting Transition Edge Sensors (TESs). For this reason, we have examined the use of partially perforated membranes for thermal management. This technique preserves the physical integrity of the membrane, and therefore maintains the mechanical robustness of the detector. This paper describes investigations of the thermal transport in trenched membranes.

47 OTHER INSTRUMENTATION↗

Low temperature thermal transport in partially perforated silicon nitride membranes.

The thermal transport in partially trenched silicon nitride membranes has been studied in the temperature range from 0.3 to 0.6 K, with the transition edge sensor (TES), the sole source of membrane heating. The test configuration consisted of Mo/Au TESs lithographically defined on silicon nitride membranes 1 {micro}m thick and 6 mm{sup 2} in size. Trenches with variable depth were incorporated between the TES and the silicon frame in order to manage the thermal transport. It was shown that sharp features in the membrane surface, such as trenches, significantly impede the modes of phonon transport. A nonlinear dependence of thermal resistance on trench depth was observed. Partial perforation of silicon nitride membranes to control thermal transport could be useful in fabricating mechanically robust detector devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The correction of linear lattice gradient errors using an AC dipole

Precise measurement of optics from coherent betatron oscillations driven by ac dipoles have been demonstrated at RHIC and the Tevatron. For RHIC, the observed rms beta-beat is about 10%. Reduction of beta-beating is an essential component of performance optimization at high energy colliders. A scheme of optics correction was developed and tested in the RHIC 2008 run, using ac dipole optics for measurement and a few adjustable trim quadruples for correction. In this scheme, we first calculate the phase response matrix from the. measured phase advance, and then apply singular value decomposition (SVD) algorithm to the phase response matrix to find correction quadruple strengths. We present both simulation and some preliminary experimental results of this correction.

43 PARTICLE ACCELERATORS↗

Analytical studies of coherent electron cooling

Under certain assumptions and simplifications, we studied a few physics processes of Coherent Electron Cooling using analytical approach. In the modulation process, the effect due to merging the ion beam with the electron beam is studied under single kick approximation. In the free electron laser (FEL) amplifier, we studied the amplification of the electron density modulation using 1D analytical approach. Both the electron charge density and the phase space density are derived in the frequency domain. The solutions are then transformed into the space domain through Fast Fourier Transformation (FFT).

43 PARTICLE ACCELERATORS↗

Search for Weakly Interacting Massive Particles with the First Five-Tower Data from the Cryogenic Dark Matter Search at the Soudan Underground Laboratory

We report results from the Cryogenic Dark Matter Search at the Soudan Underground Laboratory (CDMS II) featuring the full complement of 30 detectors. A blind analysis of data taken between October 2006 and July 2007 sets an upper limit on the weakly interacting massive particle (WIMP) nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} (4.6x10{sup -44} cm{sup 2} when combined with previous CDMS II data) at the 90% confidence level for a WIMP mass of 60 GeV/c{sup 2}. This achieves the best sensitivity for dark matter WIMPs with masses above 44 GeV/c{sup 2}, and significantly restricts the parameter space for some favored supersymmetric models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A broadband imaging system for research applications.

We have developed a compact, computer-piloted, high sensitivity broadband imaging system for laboratory research that is compatible with various detectors. Mirror optics allow application from the visible to the far infrared spectral range. A prototype tested in conjunction with a mercury cadmium telluride detector exhibits a peak detectivity of 6.7 x 10{sup 10} cm Hz{sup 1/2}/W at a wavelength of 11.8 {micro}m. Temperature and spatial resolutions of 0.06 K and 1.6 mrad, respectively, were demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal modeling of absorber-coupled TES polarimeter.

Using experimental thermal conductivity and volume heat capacity of narrow silicon nitride beams obtained from thermal test structures and a boundary limited phonon scattering model, as well as the heat conduction equation, we analyze the thermal performance of an absorber-coupled TES polarimeter with finite element method. The polarimeter's temperature distribution, thermal power readout efficiency, and time constant are calculated. The thermal power readout efficiency of the polarimeter is up to 87% at a low signal modulation frequency, and has a 0.5 dB attenuation at 120 Hz. We also compare a preliminary optical testing result with theoretical expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPTpol: an instrument for CMB polarization.

SPTpol will consist of an 850 element polarization sensitive bolometric camera deployed to the South Pole Telescope in late 2011. This camera is optimized for measurement of the polarization of the cosmic microwave background with arcminute resolution. These measurements will be used to constrain neutrino masses and to constrain the amplitude of gravitational waves from inflation. The camera includes two detector architectures that observe in two different frequency bands. At 150 GHz, SPTpol will use 650 feedhorn-coupled TES polarimeters fabricated at NIST. At 90 GHz, it will use 200 absorber-coupled polarimeters developed at Argonne National Lab. The NIST pixels will be coupled to the telescope using a monolithic array of corrugated feeds and the Argonne devices will be coupled with individually machined contoured feeds. The entire focal plane will be readout using a digital frequency-domain multiplexer system. We provide an overview of the project, describe the detectors and discuss the design of this system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and fabrication of Argonne/KICP detectors for CMB polarization.

We present the design, microfabrication and assembly of dual-polarization absorber-coupled Transition Edge Sensor (TES) bolometer detectors for cosmic microwave background B-mode polarization studies. The device consists of two separate dies incorporating suspended silicon nitride membranes within silicon frames, carefully aligned perpendicularly and fixtured face-to-face. Polarization sensitivity around 95 GHz is provided by a single dipole-like absorber element; we briefly analyze this absorber-in-waveguide configuration in closed form using the EMF method. Proximity effect Mo/Au bilayers provide control of the TES critical temperature between 400 mK and 600 mK, with a normal resistance R{sub n} {approx} 1{Omega}. DC magnetron sputtering, wet etching, and liftoff were employed for TES fabrication. Optimization of the superconducting Mo thin film utilized independent RF bias applied to the substrate during deposition in a confocal geometry. This technique allows outstanding thin film uniformity and stress to be achieved simultaneously over a 4-inch wafer surface, leading to excellent superconducting properties. Device thermal conductance in the range from 25-250pW/K was achieved using suspended silicon nitride membranes 1 micron thick. The value of the thermal conductance depends very strongly upon the surface roughness, and therefore in turn upon the treatment of the silicon nitride material during fabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical design of Argonne/KICP detectors for CMB polarization.

We present simulations and measurements of a new optical coupling scheme for bolometric detectors for cosmic microwave background (CMB) polarization under development by Argonne National Labs and the University of Chicago. We show simulations of the performance and a tolerance analysis of this device along with measurements that validate its performance. Optical measurements of a prototype point to a 90% coupling efficiency with a cross-polarization below -20 dB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical properties of Argonne/KICP TES bolometers for CMB polarimetry.

We present optical data on prototype polarization sensitive Argonne/KICP detectors fabricated at Argonne National Labs which are designed to be installed on the South Pole Telescope and used to measure the polarization of the Cosmic Microwave Background radiation. The detectors are Mo/Au transition edge sensors (TES) suspended on silicon nitride, with radiation coupled to the TES using a gold bar absorber. Two stacked detectors with bars in orthogonal directions will be used to measure both polarizations. We discuss measurements of the optical bandpass, time constants and cross-polarization of the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-situ high-energy x-ray diffuse-scattering study of the phase transition in a Ni{sub 2}MnGa ferromagnetic shape-memory crystal.

The full information on the changes in many crystallographic aspects, including the structural and microstructural characterizations, during the phase transformation is essential for understanding the phase transition and 'memory' behavior in the ferromagnetic shape-memory alloys. In the present article, the defects-related microstructural features connected to the premartensitic and martensitic transition of a Ni{sub 2}MnGa single crystal under a uniaxial pressure of 50 MPa applied along the [110] crystallographic direction were studied by the in-situ high-energy X-ray diffuse-scattering experiments. The analysis of the characteristics of diffuse-scattering patterns around different sharp Bragg spots suggests that the influences of some defect clusters on the pressure-induced phase-transition sequences of Ni2MnGa are significant. Our experiments show that an intermediate phase is produced during the premartensitic transition in the Ni{sub 2}MnGa single crystal, which is favorable for the nucleation of a martensitic phase. The compression stress along the [110] direction of the Heusler phase can promote the premartensitic and martensitic transition of the Ni{sub 2}MnGa single crystal.

36 MATERIALS SCIENCE↗

Local structures surrounding Zr in nanostructurally stabilized cubic zirconia: Structural origin of phase stability

Local environment surrounding Zr atoms in the thin films of nanocrystalline zirconia (ZrO{sub 2}) has been investigated by using the extended x-ray absorption fine structure (EXAFS) technique. These films prepared by the ion beam assisted deposition exhibit long-range structural order of cubic phase and high hardness at room temperature without chemical stabilizers. The local structure around Zr probed by EXAFS indicates a cubic Zr sublattice with O atoms located on the nearest tetragonal sites with respect to the Zr central atoms, as well as highly disordered locations. Similar Zr local structure was also found in a ZrO{sub 2} nanocrystal sample prepared by a sol-gel method. Variations in local structures due to thermal annealing were observed and analyzed. Most importantly, our x-ray results provide direct experimental evidence for the existence of oxygen vacancies arising from local disorder and distortion of the oxygen sublattice in nanocrystalline ZrO{sub 2}. These oxygen vacancies are regarded as the essential stabilizing factor for the nanostructurally stabilized cubic zirconia.

36 MATERIALS SCIENCE↗

Detection of zonal flow spectra in DIII-D by a dual-channel Doppler backscattering system

Doppler backscattering (DBS) has been successfully used to measure the ExB flow velocity and local intermediate wavenumber density fluctuation levels in the DIII-D tokamak. Depending on the launch angle and the frequency of the probing beam, the signal backscattered from the plasma cut-off layer is sensitive to density fluctuations at a specific perpendicular wavenumber (1{<=}k{sub perpendicular}{rho}{sub s}{<=}4). Due to the localization and high time resolution for poloidal flow measurements, DBS is well suited to detect stationary and time-dependent shear flows [zonal flows (ZFs)]. We present a novel scheme to measure ZF spectra using a dual-channel DBS system capable of simultaneously probing two minor radii separated by a distance of 0.2 cm<{delta}r<3 cm. Frequency spectra of geodesic acoustic modes and low frequency ZFs (f{<=}10 kHz) have been obtained for 0.6<r/a<0.95.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A correlation electron cyclotron emission diagnostic and the importance of multifield fluctuation measurements for testing nonlinear gyrokinetic turbulence simulations

A correlation electron cyclotron emission (CECE) diagnostic has been used to measure local, turbulent fluctuations of the electron temperature in the core of DIII-D plasmas. This paper describes the hardware and testing of the CECE diagnostic and highlights the importance of measurements of multifield fluctuation profiles for the testing and validation of nonlinear gyrokinetic codes. The process of testing and validating such codes is critical for extrapolation to next-step fusion devices. For the first time, the radial profiles of electron temperature and density fluctuations are compared to nonlinear gyrokinetic simulations. The CECE diagnostic at DIII-D uses correlation radiometry to measure the rms amplitude and spectrum of the electron temperature fluctuations. Gaussian optics are used to produce a poloidal spot size with w{sub o}{approx}1.75 cm in the plasma. The intermediate frequency filters and the natural linewidth of the EC emission determine the radial resolution of the CECE diagnostic, which can be less than 1 cm. Wavenumbers resolved by the CECE diagnostic are k{sub {theta}}{<=}1.8 cm{sup -1} and k{sub r}{<=}4 cm{sup -1}, relevant for studies of long-wavelength turbulence associated with the trapped electron mode and the ion temperature gradient mode. In neutral beam heated L-mode plasmas, core electron temperature fluctuations in the region 0.5<r/a<0.9, increase with radius from {approx}0.5% to {approx}2%, similar to density fluctuations that are measured simultaneously with beam emission spectroscopy. After incorporating 'synthetic diagnostics' to effectively filter the code output, the simulations reproduce the characteristics of the turbulence and transport at one radial location r/a=0.5, but not at a second location, r/a=0.75. These results illustrate that measurements of the profiles of multiple fluctuating fields can provide a significant constraint on the turbulence models employed by the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in the Physics Basis of the Hybrid Scenario on DIII-D

Recent experiments on DIII-D have extended the hybrid scenario towards the burning plasma regime by incorporating strong electron heating, low torque injection, and edge localized mode (ELM) suppression. Hybrid performance projecting to Q {ge} 10 on ITER at q{sub 95}=3.1 has been achieved in plasmas with reduced ion/electron temperature ratio or Mach number. Confinement is decreased relative to previous hybrid results, consistent with measurements of increased turbulence at low and intermediate wavenumbers. For the first time, large type-I ELMs have been completely suppressed in a hybrid plasma at q{sub 95}=3.6 by applying edge resonant magnetic perturbations (RMPs) with toroidal mode number n=3. Additionally, high performance hybrid and steady-state scenario operation has been demonstrated with reduced frequency of wall conditioning with a >95% graphite plasma-facing wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exclusive studies of 130-270 MeV {sup 3}He- and 200-MeV proton-induced reactions on {sup 27}Al, {sup nat}Ag, and {sup 197}Au

Exclusive light-charged-particle and IMF spectra have been measured with the ISiS detector array for bombardments of {sup 27}Al, {sup nat}Ag, and {sup 197}Au nuclei with 130-270-MeV {sup 3}He and 200-MeV protons. The results are consistent with previous interpretations based on inclusive data that describe the global yield of complex fragments in terms of a time-dependent process. The emission mechanism for energetic nonequilibrium fragments observed at forward angles with momenta up to twice the beam momentum is also investigated. This poorly understood mechanism, for which the angular distributions indicate formation on a time scale comparable to the nuclear transit time, are accompanied primarily by thermal-like emissions. The data are most consistent with a schematic picture in which nonequilibrium fragments are formed in a localized region of the target nucleus at an early stage in the energy-dissipation process, where the combined effects of high energy density and Fermi motion produce the observed suprathermal spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗