Search NASA⌕ Search

Engineering topics

Ware, Michael

Publications and source records attributed to Ware, Michael.

Confirming X-ray Parametric Down Conversion by Time-Energy Correlation

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. Using an incoming pump beam at 22 keV, we observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal. Our maximum rate of observed pairs was 130 /hour, corresponding to a conversion efficiency for the down-conversion process of 5.3±0.5×10 -13 .

47 OTHER INSTRUMENTATION↗

Experimental observation of polarization-resolved nonlinear Thomson scattering of elliptically polarized light

We report experimental results from a study of nonlinear Thomson scattering of elliptically polarized light. Polarization-resolved radiation patterns of the scattered light are measured as a function of the elliptical polarization state of the incident laser light. The relativistic electron trajectory in intense elliptically polarized fields leads to the formation of unique radiated polarization states, which are observed by our measurements and predicted by a theoretical model. The polarization of Thomson scattered light depends strongly on the intensity of the incident light due to nonlinearity. The results are relevant to high-field electrodynamics and to research and development of light sources with novel capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Sorbent to Clean Up Biogas for CHPs

In this project, TDA Research Inc. (TDA) has developed low-cost (on a per unit volume of gas processed basis), high-capacity expendable sorbents that can remove both the H 2 S and organic sulfur species in biogas to the ppb levels. The proposed sorbents will operate downstream of a bulk desulfurization system as a polishing bed to provide an essentially sulfur-free gas to a fuel cell (or any other application that needs a completely sulfur-free feed). Our sorbents use a highly dispersed mixed metal oxides active phase with desired modifiers prepared over on a mesoporous support. The support structure allows the large organic sulfur compounds (such as the diethyl sulfide and dipropyl sulfide phases with a large kinetic diameter) to enter the sorbent pores so that they can be adsorbed and removed from the gas stream.

09 BIOMASS FUELS↗

Characterization of optical constants for uranium from 10 to 47 nm

We use a laser high-harmonics-based extreme-ultraviolet (EUV) polarimeter to determine the optical constants of elemental uranium in the wavelength range from 10 to 47 nm. The constants are extracted from the measured ratio of p-polarized to s-polarized reflectance from a thin uranium film deposited in situ. The film thickness is inferred from a spectroscopic ellipsometry measurement of the sample after complete oxidation in room air. Uranium has been used as a high-reflectance material in the EUV. However, difficulties with oxidation prevented its careful characterization previous to this study. We find that measured optical constants for uranium vary significantly from previous estimates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗