Search NASA⌕ Search

Engineering topics

Warmack, Bruce

Publications and source records attributed to Warmack, Bruce.

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Comparison of Power System Current Sensors via Playback of Electrical Disturbances

The need to accurately measure high-frequency content in power system voltage and current phenomena is increasingly becoming more of a priority. As the amount of distributed energy resources (DER) and nonlinear loads penetrating the grid increases, so do challenges associated with traditional measurement and metering applications. In this paper, three commercially-available medium-voltage-level current sensors are characterized in terms of their harmonic amplitude and phase performance against reference signals that are “played back” through the sensors through the use of an arbitrary waveform generator. It is shown that none of the three sensors studied are able to faithfully replicate all of the input signals completely, though there are advantages and disadvantages to each in terms of noise, resonance, and induced phase drift. Additionally, the Goodness-of-Fit metric, typically used for PMU model validation, is used to generate side-by-side comparisons of sensor accuracy over a small window around the events under study.

Wilson, Aaron↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗