Search NASA⌕ Search

Engineering topics

Warner, Marvin G

Publications and source records attributed to Warner, Marvin G.

Binding of stereognostically designed ligands to trivalent, pentavalent, and hexavalent f-block elements

Stability constants were determined for the complexes formed from two stereognostically designed ligands and the f-block elements Nd(III), Np(V), and Pu(VI). The ligands investigated were tris[3-(2-carboxyphenoxy)propyl]amine (NPB) and tris-N,N',N''-[2-(2-carboxy-4-ethyl-phenoxy)ethyl]-1,4,7-triazacyclononane (EETAC). A stereognostically blind ligand, nitrilotriacetic acid (NTA), was also investigated for comparison. The results suggest that there is no significant stereognostic effect for complexation of NPB or EETAC to Np(V). On the other hand, a modest stereognostic effect is seen for the NPB ligand when complexed to Pu(VI), leading to an approximately 8-fold increase in the binding strength. A more significant effect is observed for the EETAC system in which a 250-fold increase in binding is observed for Pu(VI) versus Nd(III).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation of Oil-Water and Air-Water Contact Angles of Diverse Silanized Surfaces and Relationship to Fluid Interfacial Tensions

The use of air-water, {Theta}{sub wa}, or air-liquid contact angles is customary in surface science, while oil-water contact angles {Theta}{sub ow}, are of paramount importance in subsurface multiphase flow phenomena including petroleum reocovery, nonaqueous phase liquid fate and transport, and geological carbon sequestration. In this paper we determine both the air-water and oil-water contact angles of silica surfaces modified with a diverse selection of silanes, using hexadecane as the oil. The silanes included alkylsilanes, alkylarylsilanes, and silanes with alkyl or aryl groups that are functionalized with heteroatoms such as N, O, and S. These silanes yielded surfaces with wettabilities from water-wet to oil wet, including specific silanized surfaces functionalized with heteroatoms that yield intermediate wet surfaces. The oil-water contact angles for clean and silanized surfaces, excluding one partially fluorinated surface, correlate linearly with air-water contact angles with a slope of 1.41 (R = 0.981, n = 13). These data were used to examine a previously untested theoretical treatment relating air-water and oil-water contact angles in terms of fluid interfacial energies. Plotting the cosines of these contact angles against one another, we obtain a linear relationship in excellent agreement with the theoretical treatment; the data fit cos {Theta}{sub ow} = 0.667 cos {Theta}{sub ow} + 0.384 (R = 0.981, n = 13), intercepting cos {Theta}{sub ow} = -1 at -0.284. The theoretical slope, based on the fluid interfacial tensions {Theta}{sub wa}, {Theta}{sub ow}, and {Theta}{sub oa}, is 0.67. We also demonstrate how silanes can be used to alter the wettability of the interior of a pore network micromodel device constructed in silicon/silica with a glass cover plate. Such micromodels are used to study multiphase flow phenomena. The contact angle of the resulting interior was determined in situ. An intermediate wet micromodel gave a contact angle in excellent agreement with that obtained on an open planar silica surface using the same silane.

02 PETROLEUM↗

Liquid CO2 Displacement of Water in a Dual-Permeability Pore Network Micromodel

Permeability contrasts exist in multilayer geological formations under consideration for carbon sequestration. To improve our understanding of heterogeneous pore-scale displacements, liquid CO2 (LCO2) - water displacement was evaluated in a pore network micromodel with two distinct permeability zones. Due to the low viscosity ratio (logM = -1.1), unstable displacement occurred at all injection rates over two orders of magnitude. LCO2 displaced water only in the high permeability zone at low injection rates with the mechanism shifting from capillary fingering to viscous fingering with increasing flow rate. At high injection rates, LCO2 displaced water in the low permeability zone with capillary fingering as the dominant mechanism. LCO2 saturation (SLCO2) as a function of injection rate was quantified using fluorescent microscopy. In all experiments, more than 50% of LCO2 resided in the active flowpaths, and this fraction increased as displacement transitioned from capillary to viscous fingering. A continuum-scale two-phase flow model with independently determined fluid and hydraulic parameters was used to predict SLCO2 in the dual-permeability field. Agreement with the micromodel experiments was obtained for low injection rates. However, the numerical model does not account for the unstable viscous fingering processes observed experimentally at higher rates and hence overestimated SLCO2.

54 ENVIRONMENTAL SCIENCES↗

Influence of Viscous and Capillary Forces on Immiscible Fluid Displacement: Pore-Scale Experimental Study in a Water-Wet Micromodel Demonstrating Viscous and Capillary Fingering

Unstable immiscible fluid displacement in porous media affects geological carbon sequestration, enhanced oil recovery, and groundwater contamination by nonaqueous phase liquids. Characterization of immiscible displacement processes at the pore-scale is important to better understand macroscopic processes at the continuum-scale. A series of displacement experiments was conducted to investigate the impacts of viscous and capillary forces on displacement stability and fluid saturation distributions in a homogeneous water-wet pore network micromodel with precisely-microfabricated pore structures. Displacements were studied using seven wetting-nonwetting fluid pairs with viscosity ratios M (viscosity of the advancing nonwetting fluid divided by the viscosity of the displaced wetting fluid) ranging four orders of magnitude from logM = -1.95 to 1.88. The micromodel was initially saturated with either polyethylene glycol 200 (PEG200) or water as a wetting fluid, which was then displaced by a nonwetting alkane fluid under different flow rates. Capillary numbers (Ca) ranged over four orders of magnitude for the reported experiments, from logCa = -5.88 to -1.02. Fluorescent microscopy was used to visualize displacement and measure nonwetting fluid saturation distributions. These experiments extend the classical work by Lenormand et al. by using water-wet micromodels, high-precision fabrication, and enhanced image analysis of the saturation distributions. In the micromodel experiments initially saturated with PEG200, a viscous wetting fluid, unstable displacement occurred by viscous fingering over the whole range of imposed capillary numbers. For the experiments initially saturated with water, unstable displacement occurred by capillary fingering at low capillary numbers. When the viscous forces were increased by increasing the injection rate, crossover into stable displacement was observed for the fluid pairs with M > 0. For unstable displacement experiments applying the same capillary number for the various fluid pairs, nonwetting fluid saturations were higher when capillary fingering was the dominant fingering process compared to viscous fingering. Our saturation distributions are consistent with other published experimental work and confirm the numerical results obtained by Lenormand et al.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sigma Team for Minor Actinide Separation: PNNL FY 2011 Status Report

This report summarizes work conducted in FY 2011 at PNNL to investigate new methods of separating the minor actinide elements (Am and Cm) from the trivalent lanthanide elements, and separation of Am from Cm. For the former, work focused on a solvent extraction system combining an acidic extractant (HDEHP) with a neutral extractant (CMPO) to form a hybrid solvent extraction system referred to as TRUSPEAK (combining the TRUEX and TALSPEAK processes). For the latter, ligands that strongly bing uranyl ion were investigated for stabilizing corresponding americyl ion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significant levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid and Efficient Protein Digestion using Trypsin Coated Magnetic Nanoparticles under Pressure Cycles

Trypsin-coated magnetic nanoparticles (EC-TR/NPs), prepared via a simple crosslinking of the enzyme to magnetic nanoparticles, were highly stable and could be easily captured using a magnet after the digestion was complete. EC-TR/NPs showed a negligible loss of trypsin activity after multiple uses and continuous shaking, while a control sample of covalently-attached trypsin on NPs resulted in a rapid inactivation under the same conditions due to the denaturation and autolysis of trypsin. Digestions were carried out on a single model protein, a five protein mixture, and a whole mouse brain proteome, and also compared for digestion at atmospheric pressure and 37 ºC for 12 h, and in combination with pressure cycling technology (PCT) at room temperature for 1 min. In all cases, the EC-TR/NPs performed equally as well or better than free trypsin in terms of the number of peptide/protein identifications and reproducibility across technical replicates. However, the concomitant use of EC-TR/NPs and PCT resulted in very fast (~1 min) and more reproducible digestions.

59 BASIC BIOLOGICAL SCIENCES↗

A note on the visualization of wetting film structures and a nonwetting immiscible fluid in a pore network micromodel using a solvatochromic dye

Nile Red is demonstrated as a single dye whose solvatochromism enables selective visualization of two immiscible liquid fluids in a micromodel containing a homogeneous array of pillars creating a porous network. Nile Red dissolves in and partitions between hexadecane as a nonwetting fluid and PEG200 as a hydrophilic fluid that wets the silicon oxide surfaces in the micromodel. Both the absorption spectra and fluorescence emission spectra are sensitive to the solvent environment, such that the two phases can be distinguished by the observed color or the fluorescence emission band. Bright field, hyperspectral, epifluorescence, and confocal fluorescence methods were used to image the micromodel after displacing PEG200 in the model with hexadecane. The use of Nile Red with these imaging methods facilitates visualization of phase identity at specific locations; the interfaces between the two immiscible liquid phases; wetting behavior of the wetting phase within the porous structure; and retention of the wetting phase as thin films around pillars and as bridges across the pore throats. The pillars and wetting phase bridges create a network of obstacles defining a tortuous preferential flow path for the nonwetting phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionalized Nanoporous Silica for Removal of Heavy Metals from Biological Systems; Adsorption and Application

Functionalized nanoporous silica, often referred to as self-assembled monolayers on mesoporous supports (SAMMS) have previously demonstrated the ability to serve as very effective heavy metal sorbents in a range of aquatic and environmental systems suggesting they may be advantageously utilized for biomedical applications such as chelation therapy. Herein we evaluate surface chemistries for heavy metal capture from biological fluids, various facets of the materials biocompatibility and the suitability of these materials as potential therapeutics. Of the materials tested, thiol-functionalized SAMMS proved most capable of removing selected heavy metals from biological solutions (i.e. blood, urine, etc.) As a result, thiol SAMMS was further analyzed to assess the material’s performance under a number of different biologically relevant conditions (i.e. variable pH and ionic strength) as well to gauge any potentially negative cellular effects resulting from interaction with the sorbent, such as cellular toxicity or possible chelation of essential minerals. Additionally, cellular uptake studies demonstrated no cell membrane permeation by the silica-based materials generally highlighting their ability to remain cellularly inert and thus non-toxic. As a result, it has been determined that organic ligand-functionalized nanoporous silica materials could be a valuable material for detoxification therapeutics and potentially other biomedical applications as needed.

36 MATERIALS SCIENCE↗

Sigma Team for Minor Actinide Separation: PNNL FY 2010 Status Report

Work conducted at Pacific Northwest National Laboratory (PNNL) in FY 2010 addressed two lines of inquiry. The two hypotheses put forth were: 1. The extractants from the TRUEX( ) process (CMPO)( ) and from the TALSPEAK( ) process (HDEHP)( ) can be combined into a single process solvent to separate 1) the lanthanides and actinides from acidic high-level waste and 2) the actinides from the lanthanides in a single solvent extraction process. (Note: This combined process will hereafter be referred to as the TRUSPEAK process.) A series of empirical measurements performed (both at PNNL and Argonne National Laboratory) in FY 2009 supported this hypothesis, but also indicated some nuances to the chemistry. Lanthanide/americium separation factors of 12 and higher were obtained with a prototypic TRUSPEAK solvent when extracting the lanthanides from a citrate-buffered DTPA( ) solution. Although the observed separation factors are sufficiently high to design an actinide/lanthanide separation process, a better understanding of the chemistry is expected to lead to improved solvent formulations and improved process performance. Work in FY 2010 focused on understanding the synergistic extraction behavior observed for Nd(III) and Am(III) when extracted into mixtures of CMPO and HDEHP. The interaction between CMPO and HDEHP in dodecane was investigated by 31P NMR spectroscopy, and an adduct of the type CMPO•HDEHP was found to form. The formation of this adduct will reduce the effective extractant concentrations and must be taken into account when modeling metal ion extraction data in this system. Studies were also initiated to determine the Pitzer parameters for Nd(III) in lactate media. 2. Higher oxidation states (e.g., +5 and +6) of Am can be stabilized in solution by complexation with uranophilic ligands, and this chemistry can be exploited to separate Am from Cm. To test this hypothesis, the previously reported stereognostic uranophilic ligands NPB( ) and ETAC(e) were investigated. To assess the potential of these ligands to stabilize pentavalent and hexavalent actinides, stability constants were measured for complexation of these ligands to Nd(III), Np(V), and Pu(VI) in a solvent mixture consisting of 80% methanol/20% water. For comparison, an analogous non-stereognostic ligand, NTA,(f) was also examined. The ligand ETAC showed greater binding affinity for hexavalent Pu versus trivalent Nd by two orders-of-magnitude. Such selectivity was not observed for either NTA or NPB.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advances in Assays and Analytical Approaches for Botulinum Toxin Detection

Methods to detect botulinum toxin, the most poisonous substance known, are reviewed. Current assays are being developed with two main objectives in mind: 1) to obtain sufficiently low detection limits to replace the mouse bioassay with an in vitro assay, and 2) to develop rapid assays for screening purposes that are as sensitive as possible while requiring an hour or less to process the sample an obtain the result. This review emphasizes the diverse analytical approaches and devices that have been developed over the last decade, while also briefly reviewing representative older immunoassays to provide background and context.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thiol-Ene Induced Diphosphonic Acid Functionalization of Superparamagnetic Iron Oxide Nanoparticles

Multi-functional organic molecules represent an interesting challenge for nanoparticle functionalization due to the potential for undesirable interactions between the substrate material and the variable functionalities, making it difficult to control the final orientation of the ligand. In the present study, UV-induced thiol-ene click chemistry has been utilized as a means of directed functionalization of bifunctional ligands on an iron oxide nanoparticle surface. Allyl diphosphonic acid ligand was covalently deposited on the surface of thiol-presenting iron oxide nanoparticles via the formation of a UV-induced thioether. This method of thiol-ene click chemistry offers a set of reaction conditions capable of controlling the ligand deposition and circumventing the natural affinity exhibited by the phosphonic acid moiety for the iron oxide surface. These claims are supported via a multimodal characterization platform which includes thermogravimetric analysis, x-ray photoelectron spectroscopy, and metal contact analysis and are consistent with a properly oriented, highly active ligand on the nanoparticle surface. These experiments suggest thiol-ene click chemistry as both a practical and generally applicable strategy for the directed deposition of multi-functional ligands on metal oxide nanoparticle surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum toxin serotype A (BoNT/A). For the development of the assay, a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) has been used as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader. Detection down to 31 pM of the BoNT/Hc-fragment was demonstrated with a total incubation time of 3 hours, using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the immunochemical reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. These beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell as part of a sequential injection fluidic system. This flow cell was equipped with a fiber optic system for fluorescence measurements. In PBS buffer solution matrix, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.

60 APPLIED LIFE SCIENCES↗

Rapid Multiplexed Flow Cytometric Assay for Botulinum Neurotoxin Detection Using an Automated Fluidic Microbead-Trapping Flow Cell for Enhanced Sensitivity

A bead-based sandwich immunoassay for botulinum neurotoxin serotype A (BoNT/A) has been developed and demonstrated using a recombinant 50 kDa fragment (BoNT/A-HC-fragment) of the BoNT/A heavy chain (BoNT/A-HC) as a structurally valid simulant. Three different anti-BoNT/A antibodies were attached to three different fluorescent dye encoded flow cytometry beads for multiplexing. The assay was conducted in two formats: a manual microcentrifuge tube format and an automated fluidic system format. Flow cytometry detection was used for both formats. The fluidic system used a novel microbead-trapping flow cell to capture antibody-coupled beads with subsequent sequential perfusion of sample, wash, dye-labeled reporter antibody, and final wash solutions. After the reaction period, the beads were collected for analysis by flow cytometry. Sandwich assays performed on the fluidic system gave median fluorescence intensity signals on the flow cytometer that were 2-4 times higher than assays performed manually in the same amount of time. Limits of detection were estimated at 1 pM (~50 pg/mL for BoNT/A-HC-fragment) for the 15 minute fluidic assay.

60 APPLIED LIFE SCIENCES↗

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Fluidic Format

A renewable surface biosensor for rapid detection of botulinum toxin is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant fragment of the toxin heavy chain as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate epitopes of both this fragment and the holotoxin. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by the sequential injection flow system, creating a 3.6 microliter column. After perfusing the bead column with sample and washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degree angle to one another delivered excitation light from a HeNe laser and collected fluorescent emission light for detection. After each measurement, the used sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes.

59 BASIC BIOLOGICAL SCIENCES↗

Direct detection of Pb in urine and Cd, Pb, Cu, and Ag in natural waters using electrochemical sensors immobilized with DMSA functionalized magnetic nanoparticles

Urine is universally recognized as one of the best non-invasive matrices for biomonitoring exposure to a broad range of xenobiotics including toxic metals. For direct, simple, and field-deployable monitoring of urinary Pb, electrochemical sensors employing superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) has been developed. The metal detection involves rapid collection of dispersed metal-bound nanoparticles from a sample solution at a magnetic or electromagnetic electrode, followed by the stripping voltammetry of the metal in acidic medium. The sensors were evaluated as a function of solution pH, the binding affinity of Pb to DMSA-Fe3O4, the ratio of nanoparticles per sample volume, preconcentration time, and Pb concentrations. The effect of binding competitions between the DMSA-Fe3O4 and urine constituents for Pb on the sensor responses was studied. After 90s of preconcentration in samples containing 25 vol.% of rat urine and 0.1 g/L of DMSA-Fe3O4, the sensor could detect background level of Pb (< 1 ppb) and yielded linear responses from 0 to 50 ppb of Pb, excellent reproducibility (%R.S.D of 5.3 for seven measurements of 30 ppb Pb), and Pb concentrations comparable to those measured by ICP-MS. The sensor could also simultaneously detect background levels (< 1 ppb) of Cd, Pb, Cu, and Ag in river and seawater.

Environmental Molecular Sciences Laboratory↗

DCE Bio Detection System Final Report

The DCE (DNA Capture Element) Bio-Detection System (Biohound) was conceived, designed, built and tested by PNNL under a MIPR for the US Air Force under the technical direction of Dr. Johnathan Kiel and his team at Brooks City Base in San Antonio Texas. The project was directed toward building a measurement device to take advantage of a unique aptamer based assay developed by the Air Force for detecting biological agents. The assay uses narrow band quantum dots fluorophores, high efficiency fluorescence quenchers, magnetic micro-beads beads and selected aptamers to perform high specificity, high sensitivity detection of targeted biological materials in minutes. This final report summarizes and documents the final configuration of the system delivered to the Air Force in December 2008

59 BASIC BIOLOGICAL SCIENCES↗