Search NASA⌕ Search

Engineering topics

Warsinger, David M.

Publications and source records attributed to Warsinger, David M..

Dual-module humidity pump for efficient air dehumidification: Demonstration and performance limitations

Condensation dehumidification in conventional air conditioning technologies is energy-intensive, accounting for up to 50% of building cooling energy used in some climates. Selective vacuum membrane dehumidification (VMD) is one of the leading alternative dehumidification technologies due to its potential for significant energy savings, and the “dual-module humidity pump” is one of the most promising VMD concepts. Here, this work is the first to provide experimental proof-of-concept for the dual-module humidity pump system and provides the first thermodynamic modeling framework that accounts for realistic steady-state operating limitations, both of which are lacking in the current literature. Additionally, this work is the first to provide a system design solution that overcomes practical challenges associated with air accumulation in the vacuum channels. The experimental results in this work show that the current prototype can remove up to 45% of the water vapor in the air stream, and the vapor pressure difference in the vapor rejection module needs to be approximately 2–4 times greater than that of the dehumidification module in order to maintain balanced mass transfer. The thermodynamic model applied to typical air conditioning conditions shows that the ideal dehumidification (latent) COPs can reach up to 40, but practical COPs are limited to approximately 10. Furthermore, the model shows that the overall energy efficiency increases as the membrane air selectivity increases, though this improvement gradually starts to diminish when the membrane selectivity is increased above 10,000.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Superhydrophobic composite asymmetric electrospun membrane for sustainable vacuum assisted air gap membrane distillation

Membrane distillation (MD) relies on superhydrophobic membranes that must achieve the competing goals of high liquid entry pressure (LEP) and high permeability. Here, in this study, we developed the first superhydrophobic composite electrospun asymmetric membrane using fluorinated graphite (FG). We also provided among the first comparisons of the relative benefits of membrane asymmetry and composite coatings via 3D electrospinning and spraying. FG particles increased the roughness and reduced the zeta potential of the membranes. Superhydrophobic composite membranes had a contact angle of 157° (sliding angle of 7°) and an LEP of 327 kPa. Long-term MD testing revealed that FG particles could increase MD's sustainability while decreasing membrane wetting. Vacuum-assisted air gap membrane distillation (V-AGMD) showed that the composite asymmetric membrane outperformed the non-asymmetric version (composite nanofiber) membrane by 21 % in average water flux and 25 % in average thermal efficiency because of the asymmetric structure of the membrane. The numerical model developed for the V-AGMD system also successfully predicted the water flux generated experimentally from the composite nanofiber and composite asymmetric membranes. Our results confirmed that electrospun asymmetric FG membranes with high contact angle, low sliding angle, high permeability, and high gained output ratio (GOR) would be promising candidates for sustainable MD.

36 MATERIALS SCIENCE↗

Porous condensers can double the efficiency of membrane distillation

Among membrane distillation (MD) configurations, air gap MD (AGMD) has superior energy efficiency at high salinity. However, flooding of the gap prevents optimal thin gap depths as water removal is a challenge. To address these challenges, this work provides the first analysis of efficiency enhancement via porous wicking conductive condensers in MD. To do so, we examined performance with experiments and comprehensive thermo-fluid numerical models; we find that the porous wick condenser significantly improves thermal efficiency, gain output ratio (GOR), and flux. MD experiments show that the porous copper foam improves the thermal efficiency of air gap membrane distillation up to 40 % and water flux up to 144 %. Numerical modeling shows the porous copper foam improves the GOR of membrane distillation in high salinity by 98.7 %, outperforming air gap MD, permeate gap MD, and conductive gap MD. Furthermore, the optimized thickness and permeability of porous condensers significantly help eliminate the risk of flooding in AGMD.

42 ENGINEERING↗