This report is a continuation of the work performed in the report, Mo-100 Disk Structural Integrity Tests I [1]. The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in-beam during production. These large temperature gradients cause high stress and deformation within the disks that could prove detrimental to the target assembly’s cooling performance. Disk fracture is also a possibility that must be understood. Therefore, disk structural integrity tests were performed to understand the thermal induced behavior of these disks. In order to replicate the in-beam conditions, the Mo-100 disks were subjected to large temperature gradients using a 30kW induction heater and coil. A series of transient tests were conducted in a similar fashion as the previous work, as well as an attempt to create steady state conditions for more accurate temperature gradients. The transient thermal test setup and results are described in this report.
Explore the source record for details and available documents.
The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in beam during production. The beam preferentially heats the disk center, while the aggressive cooling by the helium keeps areas outside the beam spot relatively cool. The result is a temperature gradient of up to 900°C over the radial distance of 14.5 mm. To test the disk integrity with this high temperature gradient, a special holder for a single disk was made such that proper cooling can be applied as in the design target and the disk heating can be replicated with induction heating. NorthStar press and sintered disks were used for these tests.
A pseudo real-time interactive reactor simulator for the Lady Godiva reactor has been developed using the GNU Octave software package. The simulator tracks the time-dependent power and fuel temperature behavior of the Lady Godiva reactor during sub-prompt critical transients. Users interact with the simulator by controlling reactivity input. This input occurs through users repositioning a control rod as desired during simulator operation. Various reactor parameters are displayed graphically in near “real time,” facilitating user assessment and feedback input. The reactor model consists of a lumped-fuel core, a single control rod, and a simple heat transfer mechanism that allows heat to be rejected from the core. The goal of the simulator is to demonstrate in real-time the system response to reactivity perturbations, the effect of reactivity feedback, and the effect of temperature-dependent equilibrium conditions. The dynamic behavior of the reactor is primarily driven by the relative characteristic time-constants between the delayed neutrons and the overall heat transfer parameter. The simulator will allow users to gain experience performing standard reactor operations, such as establishing steady-state at different fuel temperatures and making power level changes
Tests were completed for window to “first disk” (actually a steel plate for these expariments) gaps of 20 mil as per design gap as well as 10 mil and 30 mil gaps to span the range of possible variations. With possible disk distortion in beam, another test with 0 gap was performed. Based on deflections measured during the pressure test, the 0 gap was most likely very near 3 mil.
Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Thirteen long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All thirteen long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the thirteenth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, III, and IV.
In FY20, Los Alamos National Laboratory (LANL) performed technical interface coordination with SHINE including coordination of SHINE CFD and thermal hydraulics conference calls, national laboratory conference calls, and program management activities such as reporting and tracking requirements for current FY20 activities. SHINE did not request any general technology consultation support for emergent issues. LANL has participated in the bi-weekly conference calls with SHINE and other national laboratories regarding LANL’s current activities. Activities discussed include the Supo 3-D CFD model geometry validation, releasing the CFD-MCNP coupled codes for the generic solution vessel simulations, and the ANL bubble experiment #2 design, preparation, and collaboration.
The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.
In collaboration with Argonne National Laboratory (ANL), Los Alamos National Laboratory (LANL) is assisting in the design and development of portions of the second ANL Bubble Experiment to be performed in late 2020 at ANL. The ANL Bubble Experiment, as called in this report, is a series of direct electron irradiations of a uranyl sulfate solution to produce radiolysis-induced gas bubbles of hydrogen and oxygen. The gas bubbles formed in the solution enhance mixing and heat transfer. The study of the dynamics, shape, and size of radiolysis-induced gas bubbles is of great importance to understand and characterize the thermal and fluid behavior of the solution, especially for the solution based, neutron-induced fission production technique for Mo-99. During the first experiment performed in 2014, ANL’s 35 MeV electron linear accelerator provided average powers of 6, 12, and 15 kW using a rastered beam to homogeneously heat the 15 x 15 x 80-cm uranyl-sulfate solution. Gas bubble size, shape, velocity, solution temperature, and hydrogen and oxygen concentrations were recorded during the irradiations. The details of the experimental setup and results for the first experiment are described in the ANL reports, Design and Construction of Experiment for Direct Electron Irradiation of a Uranyl Sulfate Solution: Bubble Formation and Thermal Hydraulics Studies and Experimental Results for Direct Electron Irradiation of a Uranyl Sulfate Solution: Bubble Formation and Thermal Hydraulics Studies. The purpose of this report is to describe the issues and lessons learned associated with the first experiment and elaborate on designs to improve and obtain more accurate experimental results for the upcoming experiment.
Explore the source record for details and available documents.
This report describes the continuation of the Computational Fluid Dynamics (CFD) model of the Supo cooling system described in the reports, Supo Thermal Model Development, II, and III. In the previous reports, the solution natural convection of Supo was simulated using a 2D, axisymmetric model that altered the actual geometry. A 3D geometry of Supo will more accurately estimate the natural convection heat transfer coefficient (HTC) of the system since Supo contains several non-symmetric internal components that can only be modeled in 3D. This, in turn, will improve the natural convection HTC results for comparison purposes with past operational data and previous 2D CFD results. Unfortunately, the complexities of performing multiphase 3D CFD simulations has proven too large of a task for our current capabilities. Instead, this report will focus on the 3D model development for the 2.39 kW/L (31.3 kW) case and limitations and challenges associated with the 3D simulations.
Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Twelve long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All twelve long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the ninth test to the twelfth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, and III.
In FY19, Los Alamos National Laboratory (LANL) provided technical support for SHINE emergent needs and technical interface coordination including coordination of SHINE CFD and thermal hydraulics conference calls, Mo-99 meetings and reviews, national laboratory conference calls, and program management activities such as reporting and tracking requirements for current FY19 activities. LANL has also provided general technology consultation support for emerging issues. LANL has participated in the bi-weekly conference calls with SHINE and other national laboratories regarding LANL’s current activities. Activities discussed include FY18 carryover items including the ANSYS Fluent-Nek5000 comparison study (for assessment of Nek5000 for coupled calculations), Supo 3-D CFD model geometry validation, and releasing CFD-MCNP coupled codes for the generic solution vessel simulations. Also, additional mid-year funded activities discussed during these conference calls include the ANL bubble experiment #2 collaboration. SHINE had a general technology consultation request in FY19. SHINE inquired about LANL’s capability to measure enrichment percentage of uranium samples, however, additional information is needed to continue. The meeting minutes for these activities are shown in Appendix A. LANL has also been providing monthly updates on the laboratory SharePoint site (managed by Pacific Northwest National Laboratory) regarding current FY19 activities. Monthly updates include current activity milestone and deliverable status, completion date updates and variances if applicable, and actual cost at the task dependent activity level. LANL attended several Mo-99 meetings and reviews in FY19. LANL attended the FY19 Mo-99 Laboratory Mid-Year Program and Financial Review at Argonne National Laboratory (ANL) on March 20-21, 2019, as well as the FY19 Mo-99 Program Meeting and Mid-Year Financial Review in Chicago, IL on April 29-30, 2019. LANL also attended the FY20 Laboratory Work Package Planning Meeting at ANL on June 4-6, 2019.
This report describes the continuation of thermal experiments using the resistively heated target assembly within the helium flow loop at LANSCE that is described in the report, Resistively Heated Target Tests Using Helium Flow Loop, by Alexander Wass et al. In order to replicate off-normal operating scenarios of the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, cooled via helium, and modified slightly. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater. A total of three scenarios were performed. One unmodified scenario, and two off-normal scenarios were conducted to simulate a blocked cooling channel due to debris within the flow loop and a broken disk during in-beam heating at the Mo-99 production facility. A removable insert was placed within a cooling channel to block the flow of helium, and a resistive heater was removed to simulate a broken disk that had been evacuated from the target assembly. The inlet and outlet cooling pipe employs rectangular tubing to make a 90° bend at a radius consistent with and practical for the actual plant design.
A helium flow and heat transfer experiment has been conducted using the helium flow loop facility at the Los Alamos National Laboratory. In order to replicate the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, and cooled via helium. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater.Computation fluid dynamic (CFD) simulations and analysis from theory are compared to the experiment results in order to have predictable capabilities for future experiments.
In FY18, Los Alamos National Laboratory (LANL) provided technical support for SHINE emergent needs and technical interface coordination including coordination of SHINE CFD/Thermal Hydraulics/transient analysis conference calls, Mo-99 meetings and reviews, national laboratory conference calls, and program management activities such as reporting and tracking requirements for cur rent FY18 activities. LANLhas also provided general technology consultation support for emerging issues.
Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Eight long duration 500 and 1000 hour tests have been completed since the first test was performed in January of 2016. All eight long duration tests have proven successful in exposing preventable issues related to oil and helium leaks.