Development of the Seeding System Used for Laser Velocimeter Surveys of the NASA Low-Speed Centrifugal Compressor Flow Field

Consideration is given to an atomizer-based system for distributing high-volume rates of polystyrene latex (PSL) seed material developed to support laser velocimeter investigations of the NASA Low-Speed Compressor flow field. Complete evaporation of the liquid carrier before the flow entering the compressor was of primary concern for the seeder system design. It is argued that the seed nozzle should incorporate a needle valve that can mechanically dislodge accumulated PSL seed material when the nozzle is turned off. Water is less expensive as the liquid carrier and should be used whenever adequate residence times are available to ensure complete evaporation. PSL agglomerates over time and needs to be mixed or blended before use. Arrangement of the spray nozzles needs to be adjustable to provide maximum seeding at the laser probe volume.

Wasserbauer, C. A.↗

The NASA Lewis Research Center Internal Fluid Mechanics Facility

An experimental facility specifically designed to investigate internal fluid duct flows is described. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints of future test hardware. The plenum flow conditioning approach is also detailed. Available instrumentation and data acquisition capabilities are discussed. The incoming flow quality was documented over the current facility operating range. The incoming flow produces well behaved turbulent boundary layers with a uniform core. For the calibration duct used, the boundary layers approached 10 percent of the duct radius. Freestream turbulence levels at the various operating conditions varied from 0.64 to 0.69 percent of the average freestream velocity.

Porro, A. R.↗

NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

Hathaway, M. D.↗

NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

Hathaway, M. D.↗

Static jet noise test results of four 0.35 scale-model QCGAT mixer nozzles

As part of the NASA Quiet Clean General Aviation Turbofan (QCGAT) engine mixer-nozzle exhaust system program, static jet exhaust noise was recorded at microphone angles of 45 to 155 deg relative to the nozzle inlet for a conventional profile coaxial nozzle and three 12-lobed coaxial mixer nozzles. Both flows in all four nozzles are internally mixed before being discharged from a single exhaust nozzle. The conventional profile coaxial nozzle jet noise is compared to the current NASA Lewis coaxial jet noise prediction and after applying an adjustment to the predicted levels based on the ratio of the kinetic energy of the primary and secondary flows, the prediction is within a standard deviation of 0.9 dB of the measured data. The mass average (mixed flow) prediction is also compared to the noise data for the three mixer nozzles with a reasonably good fit after applying another kinetic energy ratio adjustment (standard deviation of 0.7 to 1.5 dB with the measured data). The tests included conditions for the full-scale engine at takeoff (T.O.), cutback (86% T.O.) and approach (67% T.O.).

Groesbeck, D. E.↗

Cross spectra between pressure and temperature in a constant-area duct downstream of a hydrogen-fueled combustor

Pressure temperature cross spectra are necessary in predicting noise propagation in regions of velocity gradients downstream of combustors if the effect of convective entropy disturbances is included. Pressure temperature cross spectra and coherences were measured at spatially separated points in a combustion rig fueled with hydrogen. Temperature-temperature and pressure-pressure cross spectra and coherences between the spatially separated points as well as temperature and pressure autospectra were measured. These test results were compared with previous results obtained in the same combustion rig using Jet A fuel in order to investigate their dependence on the type of combustion process. The phase relationships are not consistent with a simple source model that assumes that pressure and temperature are in phase at a point in the combustor and at all other points downstream are related to one another by only a time delay due to convection of temperature disturbances. Thus these test results indicate that a more complex model of the source is required.

Miles, J. H.↗

JT150 1/2-scale nozzle jet noise experiment and comparison with prediction

As part of a program to study flight effects on the exhaust noise of a full scale JT15D engine, static half scale model jet noise experiments were conducted. Acoustic data were recorded for microphone angles of 45 deg to 155 deg with jet conditions for the model scale nozzle corresponding closely to those at 55, 73 and 97 percent of corrected rated speed for the full scale engine. These data are useful for determining the relative importance of jet and core noise in the static full scale engine test data and will in turn allow for a proper evaluation of flight effects on the exhaust noise results. The model scale data are also compared with the coaxial jet noise prediction. Above 1000 Hz, the prediction is nominally 0 to 3 dB higher than the data. The arithmetic mean of the differences between the experimental OASPL and the predicted OASPL for all angles for each run ranged from 0 to -3.2 dB. The standard deviation of all the OASPL differences is 2.2 dB. The discrepancies are greatest at low primary jet velocities and appear to be due to inadequacy in the variable jet density exponent incorporated in the prediction procedure.

Groesbeck, D. E.↗

Cross spectra between temperature and pressure in a constant area duct downstream of a combustor

The feasibility of measuring pressure temperature cross spectra and coherence and temperature-temperature cross spectra and coherence at spatially separated points along with pressure and temperature auto-spectra in a combustion rig was investigated. The measurements were made near the inlet and exit of a 6.44 m long duct attached to a J-47 combustor. The fuel used was Jet A. The cross spectra and coherence measurements show the pressure and temperature fluctuations correlate best at low frequencies. At the inlet the phenomena controlling the phase relationship between pressure and temperature could not be identified. However, at the duct exit the phase angle of the pressure is related to the phase angle of the temperature by the convected flow time delay. Previously announced in STAR as N83-23116

Miles, J. H.↗

Cross spectra between temperature and pressure in a constant area duct downstream of a combustor

The feasibility of measuring pressure temperature cross spectra and coherence and temperature-temperature cross spectra and coherence at spatially separated points along with pressure and temperature auto-spectra in a combustion rig was investigated. The measurements were made near the inlet and exit of a 6.44 m long duct attached to a J-47 combustor. The fuel used was Jet A. The cross spectra and coherence measurements show the pressure and temperature fluctuations correlate best at low frequencies. At the inlet the phenomena controlling the phase relationship between pressure and temperature could not be identified. However, at the duct exit the phase angle of the pressure is related to the phase angle of the temperature by the convected flow time delay.

Miles, J. H.↗

Analysis of combustion spectra containing organ pipe tone by cepstral techniques

Signal reinforcements and cancellations due to standing waves may distort constant bandwidth combustion spectra. Cepstral techniques previously applied to the ground reflection echo problem are used to obtain smooth broadband data and information on combustion noise propagation. Internal fluctuating pressure measurements made using a J47 combustor attached to a 6.44 m long duct are analyzed. Measurements made with Jet A and hydrogen fuels are compared. The acoustic power levels inferred from the measurements are presented for a range of low heat release rate operating conditions near atmospheric pressure. For these cases, the variation with operating condition of the overall acoustic broadband power level for both hydrogen and Jet A fuels is consistent with previous results showing it was proportional to the square of the heat release rate. However, the overall acoustic broadband power level generally is greater for hydrogen than for Jet A.

Miles, J. H.↗

FORTRAN program for predicting off-design performance of radial-inflow turbines

The FORTRAN IV program uses a one-dimensional solution of flow conditions through the turbine along the mean streamline. The program inputs needed are the design-point requirements and turbine geometry. The output includes performance and velocity-diagram parameters over a range of speed and pressure ratio. Computed performance is compared with the experimental data from two radial-inflow turbines and with the performance calculated by a previous computer program. The flow equations, program listing, and input and output for a sample problem are given.

Wasserbauer, C. A.↗

Calculated performance map of a 4 1/2-stage 15.0 centimeter (5.9 inch) mean diameter turbine designed for a turbofan simulator

The overall performance of an existing high-ratio turbine is calculated analytically over a range of speed and pressure ratio in order to determine its capability for other applications. The analytical performance covers a speed range from 50 to 120 percent of design and a pressure-ratio range from 5.0 to 35.0. The turbine was designed for a 50.8 centimeter (20.0 in.) tip diameter turbofan simulator. Computed results are compared with the experimental turbine data obtained from testing three fan configurations with the turbofan simulator in air. The comparison indicates good agreement over the range of speeds and pressure ratios covered by the experimental data.

Wasserbauer, C. A.↗

Comparison of turbine annulus mass flow computed by one- and two-dimensional analysis

Variations in specific heat ratio, flow angle, critical velocity ratio, swirl distribution exponent, and radius ratio were considered in computing the mass flow. Variations in specific heat ratio had no significant effect and variations in critical velocity ratio had only small effect on computed mass flow between a one- and two-dimensional analysis. All non-free-vortex cases considered showed larger differences in computed mass flow between one- and two-dimensional analysis than for free vortex flow. For the non-free-vortex cases, decreasing radius ratio and increasing flow angle resulted in larger differences in mass flow as computed by the two methods.

Wasserbauer, C. A.↗