Search NASA⌕ Search

Engineering topics

Watkins, J. G.

Publications and source records attributed to Watkins, J. G..

Measurements and modeling of type-I and type-II ELMs heat flux to the DIII-D divertor

Type-I and type-II edge-localized-modes (ELMs) heat flux profiles measured at the DIII-D divertor feature a peak in the vicinity of the strike-point and a plateau in the scrape-off-layer (SOL), which extends to the first wall. The plateau is present in attached and detached divertors and it is found to originate with plasma bursts upstream in the SOL. The integrated ELM heat flux is distributed at ~65% in the peak and ~35% in this plateau. The parallel loss model, currently used at ITER to predict power loads to the walls, is benchmarked using these results in the primary and secondary divertors with unprecedented constraints using experimental input data for ELM size, radial velocity, energy, electron temperature and density, heat flux footprints and number of filaments. The model can reproduce the experimental near-SOL peak within ~20%, but cannot match the SOL plateau. Employing a two-component approach for the ELM radial velocity, as guided by intermittent data, the full radial heat flux profile can be well matched. The ELM-averaged radial velocity at the separatrix, which explains profile widening, increases from ~0.2 km s –1 in attached to ~0.8 km s –1 in detached scenarios, as the ELM filaments' path becomes electrically disconnected from the sheath at the target. The results presented here indicate filaments fragmentation as a possible mechanism for ELM transport to the far-SOL and provide evidence on the beneficial role of detachment to mitigate ELM flux in the divertor far-SOL. However, these findings imply that wall regions far from the strike points in future machines should be designed to withstand significant heat flux, even for small-ELM regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct measurement of the electron turbulence-broadening edge transport barrier to facilitate core–edge integration in tokamak fusion plasmas

Abstract The integration of a high-performance core and a dissipative divertor, or the so-called ‘core–edge integration,’ has been widely identified as a critical gap in the design of future fusion reactors. In this letter, we report, for the first time, direct experimental evidence of electron turbulence at the DIII-D H-mode pedestal that correlates with the broadening of the pedestal and thus facilitates core–edge integration. In agreement with gyrokinetic simulations, this electron turbulence is enhanced by high η e ( η e = L n / L T e , where L n is the density scale length and L T e is the electron temperature scale length), which is due to a strong shift between the density and temperature pedestal profiles associated with a closed divertor. The modeled turbulence drives significant heat transport with a lower pressure gradient that may broaden the pedestal to a greater degree than the empirical and theoretically predicted pedestal width scalings. Such a wide pedestal, coupled with a closed divertor, enables us to achieve a good core–edge scenario that integrates a high-temperature low-collisionality pedestal (pedestal top temperature T e,ped > 0.8 keV and a pedestal top collisionality ν * ped < 1) under detached divertor conditions. This paves a new path toward solving the core–edge integration issue in future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on divertor detachment and pedestal characteristics in the DIII-D upper closed divertor

Abstract Experiments performed in DIII-D demonstrate that higher plasma current and heating power combined with impurity seeding facilitate the achievement of divertor detachment with a higher pedestal pressure and higher plasma performance in H-mode plasmas with a baffled closed divertor compared with an open divertor. Dedicated experiments were carried out to study the impact of power, plasma current and impurity seeding on divertor detachment with ion B × ∇ B directed into the divertor favorable for the L–H transition. With a factor of three variation in heating power and with only D 2 puffing, no significant difference in the separatrix density at detachment onset was found. The higher heating power leads to higher impurity concentration and wider scrape-off layer (SOL) width, and reduces the detachment onset density to one similar to that in lower-power plasmas. Higher current requires higher pedestal and line-averaged densities to achieve divertor detachment; however, the increase in separatrix density at increasing plasma current is found to be less pronounced. Initial calculations found that both power scan and plasma current scan datasets are qualitatively consistent with theory after considering the change in impurity concentration and heat flux width. This also motivates the future extensive study of transport and divertor impurity behavior in order to have a quantitative comparison between experiment and theory. Compared with an open divertor, a closed divertor facilitates detachment onset at ∼40% lower line-averaged plasma density. Additional N 2 seeding facilitates the achievement of detachment at a lower separatrix density and thus a higher pedestal temperature, which is beneficial for advanced tokamak scenarios. Higher heating power requires a higher N 2 puffing rate to achieve the same degree of detachment, while a higher N 2 puffing rate leads to lower detachment onset line-averaged density, both of which agree with theory. In contrast to the narrower pedestal in an open divertor approaching detachment, the pedestal density width in a closed divertor increases with density. The density gradient increases with line-averaged density at higher plasma current, but remains nearly unchanged at lower plasma current. In particular, compared with discharges with low power, at high heating power the pedestal density gradient is much weaker, while the SOL density is significantly higher and wider. At the same plasma current, both pedestal pressure gradient and temperature gradient decrease linearly with the line-averaged density but remain similar across different heating powers. Even with different plasma current and heating power, the normalized pressure gradient remains identical. As a result, achievement of divertor detachment with a higher pedestal pressure and higher plasma performance is shown in a closed divertor, which is important for improving core–edge integration as one of the critical issues for future tokamak fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of EDGDE2D-EIRENE predicted 2D distributions of electron temperature and density against divertor Thomson scattering measurements in the low-field side divertor leg in DIII-D

Comparisons of profiles of the electron temperature (T e ), density (n e ) and pressure (p e ) measured with Divertor Thomson Scattering in DIII-D low-confinement mode discharges to predictions from the edge fluid code EDGE2D-EIRENE show that the models implemented in EDGE2D-EIRENE predict the measurements within their collective uncertainties if the T e at the separatrix (T e,sep ) is 10 eV, or higher. The simulations do not predict, however, the peaked T e and ne profiles measured adjacent to the target plate when T e,sep , is below 10 eV, i.e., for the plasma downstream from the region of ionization of deuterium atoms. Inclusion of cross-field drifts and a five-fold reduction of radial transport cannot reconcile the discrepancy between the measurements and predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of high confinement, high poloidal beta plasma with dual radiated power and detachment controls for divertor protection and ELM suppression

Divertor detachment without serious core confinement quality loss in DIII-D’s high poloidal β scenario has been combined with impurity-induced ELM mitigation without disruption. Use of Ne previously granted access to a detached, non-ELMing regime that retained high confinement quality due to stimulation of Internal Transport Barrier (ITB) growth, but suffered from on-going core fuel dilution and high disruptivity. Excess Ne accumulation in the core plasma has now been avoided by feeding back core radiated power ($P_{rad}$) measurements to control Ne seeding, rather than using attachment fraction ($A_{frac}$) control with Ne; this also reduces disruptivity. At the same time, N 2 seeding is used in a feedback loop with $A_{frac}$ measurements, which previously posed low disruption risk. In this way, the effect of Ne in the core is managed while avoiding excess seeding, and N 2 acts to correct for any excess heat exhaust that might interfere with detachment. The average Ne flow rate was 38% of what was used in pure Ne $A_{frac}$ control, plus average N 2 flow that was 43% of pure N 2 $A_{frac}$ control, even while meeting an even deeper detachment target. Meanwhile, a steep pressure gradient in the core plasma reduces sensitivity to impurity-induced degradation of the pedestal and reasonable confinement quality was maintained despite operational challenges that blocked formation of an ITB in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Misalignment of magnetic field in DIII-D assessed by post-mortem analysis of divertor targets

Abstract We assess the toroidal magnetic field B t asymmetry in DIII-D due to a misalignment of the toroidal field coils with respect to the poloidal magnetic field coils and vacuum vessel. The peak-to-peak variation of the divertor strike point (SP) radius is measured to be 1 cm, with an n = 1 toroidal pattern. We use the centre of a narrow carbon deposition band on tungsten-coated divertor tiles just inside the outer strike point (OSP) as a proxy for the divertor SP location. The band occurred in a series of reverse B t discharges with the OSP positioned on the divertor inserts due to strong E × B drift transport of C from the inner to the outer SP through the private flux region. The variation in band radius (and hence the magnetic SP) is a (4.89 ± 0.31) mm shift toward (310 ± 4)° toroidal direction. These measurements agree well with previous measurements of the 3D magnetic field distribution (Luxon 2003 Nucl. Fusion 43 1813), simulations performed by the mafot field line integration code, and recent Langmuir probe measurements in the small-angle-slot (SAS) divertor (Watkins et al 2019 Nucl. Mater. Energy 18 46). Comparison of these measurements in the SAS divertor also indicates that there is the possibility of a tilt (in conjunction with the shift) of the B t coil field of (0.04 ± 0.07)° towards the toroidal angle of (215 ± 25)°. Previous measurements suggested a field misalignment of (4.6 ± 0.3) mm in the 270° toroidal direction, and a tilt of (0.06 ± 0.02)° toward the 114° toroidal direction, which is similar to the results reported here. These studies will be important for better understanding the radial variation of the toroidal strike line in DIII-D, for designing the new generation of SAS divertor, and for developing an understanding of the impact of error fields on tokamaks with tightly baffled slot divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

E × B flow driven electron temperature bifurcation in a closed slot divertor with ion B × ∇ B away from the X-point in the DIII-D tokamak

An electron temperature bifurcation is observed in the small angle slot divertor, which has been developed to enhance neutral cooling across the divertor target by coupling a closed slot structure with appropriate target shaping. Experiments in the DIII-D tokamak and associated SOLPS-ITER modeling with full drifts find a strong interplay between drifts and divertor geometry on divertor dissipation. The coupling of divertor geometry and drift flows can strongly affect the path towards divertor detachment onset as the plasma density is raised. With the strike point on the inner slanted surface and ion B × ∇B away from the magnetic X-point, bifurcative transitions were observed with sharp decrease of T e towards detachment onset both experimentally and computationally. This differs from the situation for the open divertor where the T e cliff was only observed for ion B × ∇B towards the X-point. SOLPS-ITER modeling with full drifts demonstrates that the magnitude of the E × B drift flow is comparable with the main plasma flow. The reversal of both the poloidal and radial E × B flows near the strike point leads to rapid density accumulation right near the separatrix, which results in bifurcative step transition of divertor conditions with cold plasma across the entire divertor target plate. Furthermore, these results indicate that the interplay between geometry and drifts should be fully taken into account in future fusion reactor divertor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of multiple heat flux components at the divertor target by using surface eroding thermocouples (invited)

The Surface Eroding Thermocouple (SETC) is a robust diagnostic utilized in DIII-D to provide fast, edge-localized modes (ELMs) resolved heat flux measurements, in particular in geometric regions that are too shadowed for traditional infrared thermography. In order to further investigate the power dissipation in the divertor region, a combination of flush-mounted and recessed SETCs was developed to assess the effect on surface heating from non-charged particles at the divertor target. Utilizing the Divertor Materials Evaluation System sample exposure platform, the first demonstration of the feasibility of using this new method to distinguish between the heat flux from charged particles and that from neutrals and radiative heating was achieved. This paper details the process of using the combination of flush SETCs and recessed SETCs to measure the multiple heat flux components at the divertor target and further discusses how to determine two important ratios, α (ratio of heat flux from charged particles deposit on recessed SETC to that deposit on flush SETC) and β (ratio of heat flux from non-charged particles deposit on recessed SETC to that deposit on flush SETC), in the estimation of the heat flux from non-charged particle sources. Using a time dependent ratio α, it was found that ~50% of the total incident heat flux is attributable to the non-charged particles in the fully detached open divertor in DIII-D. Finally, the new application of similar SETC diagnostics in the Small Angle Slot divertor with a V-like configuration and partial tungsten coated surface (SAS-VW) is also introduced.

47 OTHER INSTRUMENTATION↗

A Method to Identify the Heat Flux From Photons and Neutrals at the Divertor Target

The Surface Eroding Thermocouple (SETC) is a diagnostic designed for fast surface heat flux measurement and has been successfully applied in DIII-D to investigate divertor detachment. A novel method has been developed of using a combination of surface-facing and recessed SETCs to distinguish between the heat flux from charged particles, and that from neutrals and radiative heating. Furthermore, this technique suggests that at least 20% of the total incident heat flux is attributable to the latter sources not trapped in the magnetic field in a fully detached open divertor condition. It not only indicates the non-charged particle heating significantly contributes to the total surface heat flux in detached divertor conditions, but also demonstrates the feasibility of using two operational modes of SETCs to distinguish between the two surface heating mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying heat and particle flux to primary and secondary divertors for various types of edge-localized-modes

Between 15% and 30% of edge-localized-mode (ELM) heat flux can be deposited to regions outside the main divertor including the far scrape-off-layer (SOL), private flux region (PFR), and secondary divertor inner target. Analysis shown here demonstrates that type-I and small ELM plasmas are transported to the PFR and to the secondary inner divertor, which is magnetically isolated from the outer divertor, leading to well-defined heat flux profiles and with peak values that can surpass those at the secondary outer target. Such features are consistently observed for pedestal collisionalities from $ν$$^{*}_{e}$ ~1.5 to $ν$$^{*}_{e}$ ~3.9. Heat flux profiles of the examined ELM types feature rippled structures due to bursts in the outer far-SOL region but not on the secondary inner target, causing long decay lengths in the time-averaged ELM profiles. The contribution of each ELM type to the total time-averaged power deposited to the secondary divertor has been evaluated, showing that grassy ELMs contribute ~8%, small ELMs ~67%, and type-I ELMs ~85%. These findings imply that small ELMs may yet pose a concern for future machines if some regions of the main wall are not designed to withstand significant heat and particle fluxes. Due to the low intra-ELM heat flux contribution, however, the grassy ELM regime is an attractive option for an ELMing scenario in future machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achievements of actively controlled divertor detachment compatible with sustained high confinement core in DIII-D and EAST

The compatibility of efficient divertor detachment with high-performance core plasma is vital to the development of magnetically controlled fusion energy. The joint research on the EAST and DIII-D tokamaks demonstrates successful integration of divertor detachment with excellent core plasma confinement quality, a milestone towards solving the critical plasma–wall-interaction (PWI) issue and core-edge integration for ITER and future reactors. In EAST, actively controlled partial detachment with T et,div ~ 5 eV around the strike point and H 98 > 1 in different H-mode scenarios including the high β P H-mode scenario have been achieved with ITER-like tungsten divertor, by optimizing the detachment access condition and performing detailed experiments for core-edge integration. For active long-pulse detachment feedback control, a 30 s H-mode operation with detachment-control duration being 25 s has been successfully achieved in EAST. DIII-D has achieved actively controlled fully detached divertor with low plasma electron temperature (T et,div ≤ 5 eV across the entire divertor target) and low particle flux (degree of detachment, DoD > 3), simultaneously with very high core performance (β N ~3, β P > 2 and H 98 ~ 1.5) in the high βP scenario being developed for ITER and future reactors. The high-β P high confinement scenario is characterized by an internal transport barrier (ITB) at large radius and a weak edge transport barrier (ETB, or pedestal), which are synergistically self-organized. Both the high-β P scenario and impurity seeding facilitate divertor detachment. The detachment access leads to the reduction of ETB, which facilitates the development of an even stronger ITB at large radius in the high β P scenario. Thus, this strong large radius ITB enables the core confinement improvement during detachment. In conclusion, these significant joint DIII-D and EAST advances on the compatibility of high confinement core and detached divertor show a great potential for achieving a high-performance core plasma suitable for long-pulse operation of fusion reactors with controllable steady-state PWIs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing solid-surface plasma facing components for pilot plants and reactors with replenishable wall claddings and continuous surface conditioning. Part A: concepts and questions

Abstract It is estimated that pilot plants and reactors may experience rates of net erosion and deposition of solid plasma facing component (PFC) material of 10 3 –10 5 kg yr −1 . Even if the net erosion (wear) problem can be solved, the redeposition of so much material has the potential for major interference with operation, including disruptions due to so-called ‘unidentified flying objects (UFOs)’ and unsafe dust levels. The potential implications appear to be no less serious than for plasma contact with the divertor target: a dust explosion or a major UFO-disruption could be as damaging for an actively-cooled deuterium-tritium (DT) tokamak as target failure. It will therefore be necessary to manage material deposits to prevent their fouling operation. This situation appears to require a fundamental paradigm shift with regard to meeting the challenge of taming the plasma–material interface: it appears that any acceptable solid PFC material will in effect be flow-through , like liquid–metal PFCs, although at far lower mass flow rates. Solid PFC material will have to be treated as a consumable , like brake pads in cars. ITER will use high-Z (tungsten) armor on the divertor targets and low-Z (beryllium) on the main walls. The ARIES-AT reactor design calls for a similar arrangement, but with SiC cladding on the main walls. Non-metallic low-Z refractory materials such as ceramics (graphite, SiC, etc) used as in situ replenishable, relatively thin—of order mm—claddings on a substrate which is resistant to neutron damage could provide a potential solution for the main walls, while reducing the risk of degrading the confined plasma. Separately, wall conditioning has proven essential for achieving high performance. For DT devices, however, standard methods appear to be unworkable, but recently powder droppers injecting low-Z material ∼continuously into discharges have been quite effective and may be usable in DT devices as well. The resulting massive generation of low-Z debris, however, has the same potential to seriously disrupt operation as noted above. Powder droppers provide a unique opportunity to carry out controlled studies on the management of low-Z slag in all current tokamaks, independent of whether their protection tiles use low-Z or high-Z material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing solid-surface plasma facing components for pilot plants and reactors with replenishable wall claddings and continuous surface conditioning. Part B: required research in present tokamaks

Abstract The companion part A paper (Stangeby et al 2022) reports a number of independent estimates indicating that high-duty-cycle DT tokamaks starting with pilot plants will likely experience rates of net erosion and deposition of solid PFC, plasma facing component, material in the range of 10 3 to 10 4 kg yr −1 , regardless of the material used. The subsequent redeposition of such large quantities of material has the potential for major interference with tokamak operation. Similar levels and issues will be involved if ∼continuous low-Z powder dropping is used for surface conditioning of DT tokamaks, independent of the material used for the PFC armor. In Stangeby et al (2022) (part A) it is proposed that for high-duty-cycle DT tokamaks, non-metallic low-Z refractory materials such as ceramics (graphite, SiC, etc) used as in situ replenishable, relatively thin—of order mm—claddings on a substrate which is resistant to neutron damage could provide a potential solution for protecting the main walls, while reducing the risk of degrading the confined plasma. Assessment of whether such an approach is viable will require information, much of which is not available today. Section 6 of part A identifies a partial list of major physics questions that will need to be answered in order to make an informed assessment. This part B report describes R&D needed to be done in present tokamaks in order to answer many of these questions. Most of the required R&D is to establish better understanding of low-Z slag generation and to identify means to safely manage it. Powder droppers provide a unique opportunity to carry out controlled studies on the management of low-Z slag in current tokamaks, independent of whether their protection tiles use low-Z or high-Z material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗