Search NASA⌕ Search

Engineering topics

Watson, Peter

Publications and source records attributed to Watson, Peter.

Modeling Noise: Paths toward AI-Enabled Stochastic Earth System Models and Parameterizations

Some of the key challenges in Earth system prediction arise from an uncertain representation of unpredictable natural variability, across time and space scales. This variability, hereafter referred to as noise, represents the quantity against which the strength of a signal of interest is measured to assess predictability. Underestimating or overestimating this noise in Earth system models can lead to issues ranging between overconfidence in an erroneous prediction and a lack thereof in an otherwise accurate one. Noise is part of the physical processes in the Earth system and can amplify or damp a signal of interest in a complex manner that is not systematically characterized. Specifically, while there has been significant progress in our understanding of multiscale interactions among known modes of variability (potentially predictable signals), how these are impacted by the noise is not clear. Recent effort toward stochastic parametrization schemes that provide a representation of noise due to uncertain sub-grid processes in climate models (Berner et al., 2017 and references therein) has shown promise not only in reducing biases and improving probabilistic prediction but also in improving the representation of natural variability in the model toward what is observed. However, today’s standard schemes for stochastic parametrization are still simplistic as they do not take the state of the atmosphere into account (other than by the use of multiplicative noise for model tendencies). Furthermore they require hand-tuning and trial-and-error testing for the magnitude of the added noise, which is difficult in a chaotic system that is as complex as the Earth system.

58 GEOSCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 06: Investigation of an absorbed dose to water formalism for a miniature low-energy x-ray source

Purpose: We present a formalism for calculating the absorbed dose to water from a miniature x-ray source (The INTRABEAM system, Carl Zeiss), using a parallel-plate ionization chamber calibrated in terms of air-kerma. Monte Carlo calculations were performed to derive a chamber conversion factor (C{sub Q}) from reference air-kerma to dose to water for the INTRABEAM. C{sub Q} was investigated as a function of depth in water, and compared with the manufacturer’s reported value. The effect of chamber air cavity dimension tolerance was also investigated. Methods: Air-kerma (A{sub k}) from a reference beam was calculated using the EGSnrc user code cavity. Using egs-chamber, a model of a PTW 34013 parallel-plate ionization chamber was created according to manufacturer specifications. The dose to the chamber air cavity (D{sub gas}) was simulated both in-air (with reference beam) and in-water (with INTRABEAM source). Dose to a small water voxel (D{sub w}) was also calculated. C{sub Q} was derived from these quantities. Results: C{sub Q} was found to vary by up to 15% (1.30 vs 1.11) between chamber dimension extremes. The agreement between chamber C{sub Q} was found to improve with increasing depth in water. However, in all cases investigated, C{sub Q} was larger than the manufacturer reported value of 1.054. Conclusions: Our results show that cavity dimension tolerance has a significant effect on C{sub Q}, with differences as large as 15%. In all cases considered, C{sub Q} was found to be larger than the reported value of 1.054. This suggests that the recommended calculation underestimates the dose to water.

60 APPLIED LIFE SCIENCES↗

Heavy quarks, gluons and the confinement potential in Coulomb gauge

We consider the heavy quark limit of Coulomb gauge QCD, with the truncation of the Yang-Mills sector to include only (dressed) two-point functions. We find that the rainbow-ladder approximation to the gap and Bethe-Salpeter equations is nonperturbatively exact and moreover, we provide a direct connection between the temporal gluon propagator and the quark confinement potential. Further, we show that only bound states of color singlet quark-antiquark (meson) and quark-quark (SU(2) baryon) pairs are physically allowed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Biospecimen Reporting for Improved Study Quality (BRISQ)

Human biospecimens are subjected to collection, processing, and storage that can significantly alter their molecular composition and consistency. These biospecimen preanalytical factors, in turn, influence experimental outcomes and the ability to reproduce scientific results. Currently, the extent and type of information specific to the biospecimen preanalytical conditions reported in scientific publications and regulatory submissions varies widely. To improve the quality of research that uses human tissues, it is crucial that information on the handling of biospecimens be reported in a thorough, accurate, and standardized manner. The Biospecimen Reporting for Improved Study Quality (BRISQ) recommendations outlined herein are intended to apply to any study in which human biospecimens are used. The purpose of reporting these details is to supply others, from researchers to regulators, with more consistent and standardized information to better evaluate, interpret, compare, and reproduce the experimental results. The BRISQ guidelines are proposed as an important and timely resource tool to strengthen communication and publications on biospecimen-related research and to help reassure patient contributors and the advocacy community that their contributions are valued and respected.

59 BASIC BIOLOGICAL SCIENCES↗