Single-stage electrohydraulic servosystem for actuating on airflow valve with frequencies to 500 hertz

An airflow valve and its electrohydraulic actuation servosystem are described. The servosystem uses a high-power, single-stage servovalve to obtain a dynamic response beyond that of systems designed with conventional two-stage servovalves. The electrohydraulic servosystem is analyzed and the limitations imposed on system performance by such nonlinearities as signal saturations and power limitations are discussed. Descriptions of the mechanical design concepts and developmental considerations are included. Dynamic data, in the form of sweep-frequency test results, are presented and comparison with analytical results obtained with an analog computer model is made.

Webb, J. A., Jr.

Predicting dynamic performance limits for servosystems with saturating nonlinearities

A generalized treatment for a system with a single saturating nonlinearity is presented and compared with frequency response plots obtained from an analog model of the system. Once the amplitude dynamics are predicted with the limit lines, an iterative technique is employed to determine the system phase response. The saturation limit line technique is used in conjunction with velocity and acceleration limits to predict the performance of an electro-hydraulic servosystem containing a single-stage servovalve. Good agreement was obtained between predicted performance and experimental data.

Webb, J. A., Jr.

Design and performance of heart assist or artificial heart control systems

The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

Webb, J. A., Jr.

Analysis of a stability valve system for extending the dynamic range of a supersonic inlet

A stability valve system designed for a full-scale, flight, supersonic, mixed-compression inlet was modeled dynamically by using analog computer techniques. The system uses poppet valves mounted in the inlet cowl to bypass airflow and augments the inlet shock position control system by preventing unstarts caused by high-frequency perturbations. The model was used as a design aid to investigate the effects of varying both the physical configurations of the valve and the flight and wind tunnel conditions. Results of the analysis indicate that the stability valve will provide a bandpass operation of 1 hertz to 17 hertz.

Webb, J. A., Jr.

Circuit for detecting initial systole and dicrotic notch

Circuitry is disclosed for processing an arterial pressure waveform to produce during any one cycle a pulse corresponding to the initial systole and a pulse corresponding to the dicrotic notch. In a first channel, an electrical analog of the arterial pressure waveform is filtered and then compared to the original waveform to produce an initial systole signal. In a second channel, the analog is differentiated, filtered, and fed through a gate controlled by pulses from the first channel to produce an electrical pulse corresponding to the dicrotic notch.

Gebben, V. D.

Improved design of a high response slotted plate overboard bypass valve for supersonic inlets

The electrohydraulically actuated slotted-plate bypass valve used to control the position of the normal shock during wind-tunnel investigations of supersonic inlets also has proven to be a valuable device for determining inlet dynamics and creating airflow disturbances. Operation of previous valves at high frequencies (to 100 Hz) for extended testing has resulted in numerous failures. An improved bypass-valve design is presented which increases the cyclic tolerance of the device considerably over past designs. The use of dynamic limit criteria to obtain an optimum actuator-piston size results in a frequency response which is flat within + or - 3 decibels to 120 Hz for a peak-to-peak variation of 20 percent of full area.

Webb, J. A., Jr.

Determination and evaluation of performance limit criteria of fast-response electrohydraulic servosystems

Limit criteria for determining the dynamic performance capabilities of high performance, fast-response (greater than 100 Hz) electrohydraulic servosystems are presented. A detailed analysis of the maximum load locus of these systems is used as a basis for the derivation of improved limit criteria. These criteria predict the maximum performance limits caused by system nonlinearities and physical limitations. The criteria are applied to experimental data to verify their validity. Design criteria which assist in the selection of system components for optimal performance are also discussed.

Zeller, J. R.

Cardiac R-wave detector with automatic sensitivity control

An electronic circuit that automatically changes its sensitivity was developed for detecting the bioelectric signal resulting from activation of the heart's ventricles. Regulation of sensitivity was accomplished with two feedback channels that maintain the sensitivity level between an upper and a lower limit. These limits are proportional to the R-wave amplitude. Tests on an experimental circuit demonstrated a capability to reject unwanted signal noise, illustrated difficulties encountered without sensitivity control, and presented closed loop transients which occurred for step changes in R-wave amplitude.

Gebben, V. D.

Electronic circuit detects left ventricular ejection events in cardiovascular system

Electronic circuit processes arterial blood pressure waveform to produce discrete signals that coincide with beginning and end of left ventricular ejection. Output signals provide timing signals for computers that monitor cardiovascular systems. Circuit operates reliably for heart rates between 50 and 200 beats per minute.

Gebben, V. D.

Design of a specialized computer for on-line monitoring of cardiac stroke volume

The design of a specialized analog computer for on-line determination of cardiac stroke volume by means of a modified version of the pressure pulse contour method is presented. The design consists of an analog circuit for computation and a timing circuit for detecting necessary events on the pressure waveform. Readouts of arterial pressures, systolic duration, heart rate, percent change in stroke volume, and percent change in cardiac output are provided for monitoring cardiac patients. Laboratory results showed that computational accuracy was within 3 percent, while animal experiments verified the operational capability of the computer. Patient safety considerations are also discussed.

Webb, J. A., Jr.

An electronic circuit that detects left ventricular ejection events by processing the arterial pressure waveform

An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.

Gebben, V. D.

Control system for an artificial heart

Inexpensive industrial pneumatic components are combined to produce control system to drive sac-type heart-assistance blood pump with controlled pulsatile pressure that makes pump rate of flow sensitive to venous /atrial/ pressure, while stroke is centered about set operating point and pump is synchronized with natural heart.

Gebben, V. D.