Search NASA⌕ Search

Engineering topics

Webb, James T.

Publications and source records attributed to Webb, James T..

Metabolic Cost of Experimental Exercises

Although the type and duration of activity during decompression was well documented, the metabolic cost of 1665 subject-exposures with 8 activity profiles from 17 altitude decompression sickness (DCS) protocols at Brooks City-Base, TX from 1983-2005 was not determined. Female and male human volunteers (30 planned, 4 completed) performed activity profiles matching those 8 activity profiles at ground level with continuous monitoring of metabolic cost. A Cosmed K4b2 Cardio Pulmonary Exercise Testing device was used to measure oxygen uptake (VO2) during the profiles. The results show levels of metabolic cost to the females for the profiles tested varied from 4.3 to 25.5 ml/kg/min and from 3.0 to 12.0 ml/kg/min to the males. The increase in VO2 from seated rest to the most strenuous of the 8 activity profiles was 3.6-fold for the females and 2.8-fold for the males. These preliminary data on 4 subjects indicate close agreement of oxygen uptake for activity performed during many subject-exposures as published earlier. The relatively low average oxygen uptake required to perform the most strenuous activity may imply the need for adjustment of modeling efforts using metabolic cost as a risk factor. Better definition of metabolic cost during exposure to altitude, a critical factor in DCS risk, may allow refinement of DCS prediction models.

Webb, James T.↗

Gender not a factor for altitude decompression sickness risk

INTRODUCTION: Early, retrospective reports of the incidence of altitude decompression sickness (DCS) during altitude chamber training exposures indicated that women were more susceptible than men. We hypothesized that a controlled, prospective study would show no significant difference. METHODS: We conducted 25 altitude chamber decompression exposure profiles. A total of 291 human subjects, 197 men and 94 women, underwent 961 exposures to simulated altitude for up to 8 h, using zero to 4 h of preoxygenation. Throughout the exposures, subjects breathed 100% oxygen, rested or performed mild or strenuous exercise, and were monitored for precordial venous gas emboli (VGE) and DCS symptoms. RESULTS: No significant differences in DCS incidence were observed between men (49.5%) and women (45.3%). However, VGE occurred at significantly higher rates among men than women under the same exposure conditions, 69.3% and 55.0% respectively. Women using hormonal contraception showed significantly greater susceptibility to DCS than those not using hormonal contraception during the latter two weeks of the menstrual cycle. Significantly higher DCS incidence was observed in the heaviest men, in women with the highest body fat, and in subjects with the highest body mass indices and lowest levels of fitness. CONCLUSION: No differences in altitude DCS incidence were observed between the sexes under our test conditions, although men developed VGE more often than women. Age and height showed no significant influence on DCS incidence, but persons of either sex with higher body mass index and lower physical fitness developed DCS more frequently.

NASA Discipline Environmental Health↗

Enhancement of preoxygenation for decompression sickness protection: effect of exercise duration

INTRODUCTION: Since strenuous exercise for 10 min during preoxygenation was shown to provide better protection from decompression sickness (DCS) incidence than resting preoxygenation, a logical question was: would a longer period of strenuous exercise improve protection even further? HYPOTHESIS: Increased strenuous exercise duration during preoxygenation increases DCS protection. METHODS: There were 60 subjects, 30 men and 30 women, who were exposed to 9,144 m (4.3 psia) for 4 h while performing mild, upper body exercise. Before the exposures, each subject performed three preoxygenation profiles on different days in balanced order: a 90-min resting preoxygenation control; a 240-min resting preoxygenation control; and a 90-min preoxygenation including exercise during the first 15 min. The subjects were monitored at altitude for venous gas emboli (VGE) with an echo-imaging system and observed for signs and symptoms of DCS. RESULTS: There were no significant differences in occurrence of DCS following any of the three preoxygenation procedures. Results were also comparable to an earlier report of 42% DCS with a 60-min preoxygenation including a 10-min exercise. There was no difference between VGE incidence in the comparison of protection offered by a 90-min preoxygenation with or without 13 min of strenuous exercise. The DCS incidence following a 240-min resting preoxygenation, 40%, was higher than observed during NASA studies and nearly identical with the earlier 42% DCS after a 60-min preoxygenation including exercise during the first 10 min. CONCLUSION: The protection offered by a 10 min exercise in a 60-min preoxygenation was not increased with extension of the preoxygenation exercise period to 15 min in a 90-min preoxygenation, indicating an upper time limit to the beneficial effects of strenuous exercise.

NASA Discipline Environmental Health↗

Pulmonary decompression sickness at altitude: early symptoms and circulating gas emboli

INTRODUCTION: Pulmonary altitude decompression sickness (DCS) is a rare condition. 'Chokes' which are characterized by the triad of substernal pain, cough, and dyspnea, are considered to be associated with severe accumulation of gas bubbles in the pulmonary capillaries and may rapidly develop into a life-threatening medical emergency. This study was aimed at characterizing early symptomatology and the appearance of venous gas emboli (VGE). METHODS: Symptoms of simulated-altitude DCS and VGE (with echo-imaging ultrasound) were analyzed in 468 subjects who participated in 22 high altitude hypobaric chamber research protocols from 1983 to 2001 at Brooks Air Force Base, TX. RESULTS: Of 2525 subject-exposures to simulated altitude, 1030 (41%) had symptoms of DCS. Only 29 of those included DCS-related pulmonary symptoms. Of these, only 3 subjects had all three pulmonary symptoms of chokes; 9 subjects had two of the pulmonary symptoms; and 17 subjects had only one. Of the 29 subject-exposures with pulmonary symptoms, 27 had VGE and 21 had severe VGE. The mean onset times of VGE and symptoms in the 29 subject-exposures were 42 +/- 30 min and 109 +/- 61 min, respectively. In 15 subjects, the symptoms disappeared during recompression to ground level followed by 2 h of oxygen breathing. In the remaining 14 cases, the symptoms disappeared with immediate hyperbaric oxygen treatment. CONCLUSIONS: Pulmonary altitude DCS or chokes is confirmed to be a rare condition. Our data showed that when diagnosed early, recompression to ground level pressure and/or hyperbaric oxygen treatment was 100% successful in resolving the symptoms.

Non-NASA Center↗

The effect of simulated weightlessness on hypobaric decompression sickness

BACKGROUND: A discrepancy exists between the incidence of ground-based decompression sickness (DCS) during simulated extravehicular activity (EVA) at hypobaric space suit pressure (20-40%) and crewmember reports during actual EVA (zero reports). This could be due to the effect of gravity during ground-based DCS studies. HYPOTHESIS: At EVA suit pressures of 29.6 kPa (4.3 psia), there is no difference in the incidence of hypobaric DCS between a control group and group exposed to simulated weightlessness (supine body position). METHODS: Male subjects were exposed to a hypobaric pressure of 29.6 kPa (4.3 psi) for up to 4 h. The control group (n = 26) pre-oxygenated for 60 min (first 10 min exercising) before hypobaric exposure and walking around in the altitude chamber. The test group (n = 39) remained supine for a 3 h prior to and during the 60-min pre-oxygenation (also including exercise) and at hypobaric pressure. DCS symptoms and venous gas emboli (VGE) at hypobaric pressure were registered. RESULTS: DCS occurred in 42% in the control and in 44% in simulated weightlessness group (n.s.). The mean time for DCS to develop was 112 min (SD +/- 61) and 123 min (+/- 67), respectively. VGE occurred in 81% of the control group subjects and in 51% of the simulated weightlessness subjects (p = 0.02), while severe VGE occurred in 58% and 33%, respectively (p = 0.08). VGE started after 113 min (+/- 43) in the control and after 76 min (+/- 64) in the simulated weightlessness group. CONCLUSIONS: No difference in incidence of DCS was shown between control and simulated weightlessness conditions. VGE occurred more frequently during the control condition with bubble-releasing arm and leg movements.

NASA Discipline Environmental Health↗

The effect of repeated altitude exposures on the incidence of decompression sickness

INTRODUCTION: Repeated altitude exposures in a single day occur during special operations parachute training, hypobaric chamber training, unpressurized flight, and extravehicular space activity. Inconsistent and contradictory information exists regarding the risk of decompression sickness (DCS) during such hypobaric exposures. HYPOTHESIS: We hypothesized that four short exposures to altitude with and without ground intervals would result in a lower incidence of DCS than a single exposure of equal duration. METHODS: The 32 subjects were exposed to 3 different hypobaric exposures--condition A: 2 h continuous exposure (control); condition B: four 30-min exposures with descent/ascent but no ground interval between the exposures; condition C: four 30-min exposures with descent/ascent and 60 min of ground interval breathing air between exposures. All exposures were to 25,000 ft with 100% oxygen breathing. Subjects were observed for symptoms of DCS, and precordial monitoring of venous gas emboli (VGE) was accomplished with a SONOS 1000 echo-imaging system. RESULTS: DCS occurred in 19 subjects during A (mean onset 70+/-29 min), 7 subjects in B (60+/-34 min), and 2 subjects in C (40+/-18 min). There was a significant difference in DCS incidence between B and A (p = 0.0015) and C and A (p = 0.0002), but no significant difference between B and C. There were 28 cases of VGE in A (mean onset 30+/-23 min), 21 in B (41+/-35 min), and 21 in C (41+/-32 min) with a significant onset curve difference between B and A and between C and A, but not between B and C. Exposure A resulted in four cases of serious respiratory/neurological symptoms, while B had one and C had none. All symptoms resolved during recompression to ground level. CONCLUSION: Data indicate that repeated simulated altitude exposures to 25,000 ft significantly reduce DCS and VGE incidence compared with a single continuous altitude exposure.

Non-NASA Center↗

Case Descriptions and Observations About Cutis Marmorata From Hypobaric Decompressions

There is disagreement about the pathophysiology, classification, and treatment of cutis marmorata (CM), so there is disagreement about the disposition and medical status of a person that had CM. CM is rare, associated with stressful decompressions, and may be associated with serious signs and symptoms of decompression sickness (DCS). CM presents as purple or bluish-red skin mottling, often in the pectoral region, shoulders, chest, or upper abdomen. It is unethical to induce CM in humans so all information comes from retrospective analysis of case reports, or from animal models. A literature search, seven recent case reports from the Johnson Space Center and Brooks Air Force Base Hypobaric DCS Databases, interviews with DCS treatment experts, and responses to surveys provided the factual information used to arrive at our conclusions and recommendations. The "weight of evidence" indicates that CM is a local, not centrally mediated or systemic response to bubbles. It is unclear whether obstruction of arterial or venous blood flow is the primary insult since the lesion is reported under either condition. Any neurological or cardiovascular involvements are coincidental, developing along the same time course. The skin could be the source of the bubbles due to its mass, the associated layer of fat, and the variable nature of skin blood flow. CM should not be categorized as Type II DCS, should be included with other skin manifestations in a category called cutaneous DCS, and hyperbaric treatment is only needed if ground level oxygen is ineffective in the case of altitude-induced CM.

Conkin, Johnny↗

Dual-cycle ergometry as an exercise modality during prebreathe with 100 percent oxygen

In an effort to reduce prebreathe time requirements prior to extravehicular activities and high-altitude flights, a combined arm and leg exercise task proposes to enhance denitrogenation by incorporation of both upper and lower body musculature at a moderately high work intensity during prebreathe with 100% oxygen. Preliminary findings indicated peak oxygen consumption (VO2peak) levels attained on the dual-cycle ergometer do not differ significantly from those levels attained on the treadmill. Eight male subjects were exercised to VO2peak using leg-only cycle ergometry and dual-cycle ergometry on separate days. Preliminary data during dual-cycle ergometry showed arm work equaling 30% of the leg workrate at each stage of the incremental test resulted in arm fatigue in several subjects and a reduced VO2peak compared to dual-cycle ergometry with arm work at 20%. Thus, the 20% workrate was used during the dual-cycle VO2peak trial. On a third experimental day, subjects performed a 10 minute exercise test at a workrate required to elicit 75% of VO2peak for each subject on the dual-cycle ergometer. Blood lactate response to the exercise was monitored as an objective measure of fatigue. Peak VO2 levels attained on the leg-only and the dual-cycle ergometry tasks were not significantly different. Blood lactate levels were significantly elevated following the dual-cycle ergometry at 75% VO2peak. However, lactate levels show the expected rate of decline during recovery and, as demonstrated in the literature, should return to baseline levels within 30 minutes following exercise cessation. Thus, dual-cycle ergometry at 75% VO2peak appears to be a valid exercise for use during prebreathe and should not contribute to fatigue during subsequent EVA's.

Heaps, Cristine L.↗

Exercise with prebreathe appears to increase protection from decompression sickness: Preliminary findings

Extravehicular activity (EVA) from the Space Shuttle involves one hour of prebreath with 100% oxygen, decompression of the entire Shuttle to 10.2 psia for at least 12 hours, and another prebreath for 40 minutes before decompression to the 4.3 psia suit pressure. We are investigating the use of a one-hour prebreathe with 100% oxygen beginning with a ten-minute strenuous exercise period as an alternative for the staged decompression schedule described above. The 10-minute exercise consists of dual-cycle ergometry performed at 75% of the subject's peak oxygen uptake to increase denitrogenation efficiency by increasing ventilation and perfusion. The control exposures were preceded by a one-hour prebreathe with 100% oxygen while resting in a supine position. The twenty-two male subjects were exposed to 4.3 psia for 4 hours while performing light to moderate exercise. Preliminary results from 22 of the planned 26 subjects indicate 76% DCS following supine, resting prebreathe and 38% following prebreathe with exercise. The staged decompression schedule has been shown to result in 23% DCS which is not significantly different from the exercise-enhanced prebreathe results. Prebreathe including exercise appears to be comparable to the protection afforded by the more lengthy staged decompression schedule. Completion of the study later this year will enable planned statistical analysis of the results.

Webb, James T.↗

Breathing 100 percent oxygen compared with 50 percent oxygen:50 percent nitrogen reduces altitude-induced venous gas emboli

The study investigates effects of 40 zero-prebreathe decompressions of male subjects to 8.3-6.8 psia for 6 h while they were breathing 100 percent oxygen and performing moderate exercise. No decompression sickness (DCS) symptoms were observed. Severe venous gas emboli (VGE) were not detected at 8.3 psia, but were present during 10, 20, and 40 percent of the exposures at 7.8, 7.3, and 6.8 psia, respectively. Zero-prebreathe decompression while breathing 100 percent oxygen results in significantly lower VGE and DCS risk levels than while breathing a 50:50 mix. It is shown that 7.3 psia EVA pressure suits with 100 percent oxygen should be safer than 8.3 psia suits with a 50:50 mix.

Webb, James T.↗

Hypobaric decompression prebreathe requirements and breathing environment

To reduce incidence of decompression sickness (DCS), prebreathing 100 percent oxygen to denitrogenate is required prior to hypobaric decompressions from a sea level pressure breathing environment to pressures lower than 350 mm Hg (20,000 ft; 6.8 psia). The tissue ratio (TR) of such exposures equals or exceeds 1.7; TR being the tissue nitrogen pressure prior to decompression divided by the total pressure after decompression (((0.781)(14.697))/6.758). Designing pressure suits capable of greater pressure differentials, lower TR's, and procedures which limit the potential for DCS occurrence would enhance operational efficiency. The current 10.2 psia stage decompression prior to extravehicular activity (EVA) from the Shuttle in the 100 percent oxygen, 4.3 psia suit, results in a TR of 1.65 and has proven to be relatively free of DCS. Our recent study of zero-prebreathe decompressions to 6.8 psia breathing 100 percent oxygen (TR = 1.66) also resulted in no DCS (N = 10). The level of severe, Spencer Grades 3 or 4, venous gas emboli (VGE) increased from 0 percent at 9.5 psia to 40 percent at 6.8 psia yielding a Probit curve of VGE risk for the 51 male subjects who participated in these recent studies. Earlier, analogous decompressions using a 50 percent oxygen, 50 percent nitrogen breathing mixture resulted in one case of DCS and significantly higher levels of severe VGE, e.g., at 7.8 psia, the mixed gas breathing environment resulted in a 56 percent incidence of severe VGE versus 10 percent with use of 100 percent oxygen. The report of this study recommended use of 100 percent oxygen during zero-prebreathe exposure to 6.8 psia if such a suit could be developed. For future, long-term missions, we suggest study of the effects of decompression over several days to a breathing environment of 150 mmHg O2 and approximately 52 mmHg He as a means of eliminating DCS and VGE hazards during subsequent excursions. Once physiologically adapted to a 4 psia vehicle, base, or space station segment, crew members could use greatly simplified EVA suits with greater mobility and no prebreathe requirement.

Webb, James T.↗

Validation of a dual-cycle ergometer for exercise during 100 percent oxygen prebreathing

A study has been designed to determine if exercise, while prebreathing 100 percent oxygen prior to decompression, can reduce the current resting-prebreathe time requirements for extravehicular activity and high altitude reconnaissance flight. For that study, a suitable exercise mode was required. Design considerations included space limitations, cost, pressure suit compatibility, ease and maintenance of calibration, accuracy of work output, and assurance that no significant mechanical advantage or disadvantage would be introduced into the system. In addition, the exercise device must enhance denitrogenation by incorporation of both upper and lower body musculature at high levels of oxygen consumption. The purpose of this paper is to describe the specially constructed, dual-cycle ergometer developed for simultaneous arm and leg exercise during prebreathing, and to compare maximal oxygen uptake obtained on the device to that obtained during leg-only cycle ergometry and treadmill testing. Results demonstrate the suitability of the dual-cycle ergometer as an appropriate tool for exercise research during 100 percent oxygen prebreathing.

Wiegman, Janet F.↗

Decompression sickness and venous gas emboli at 8.3 psia

This study sought to determine the bends risk on decompression from sea level to 8.3 psia. On the basis of several prior studies by NASA and the Air Force, this differential was expected to result in a minimal (about 5 percent) incidence of mild decompression sickness, and may be the pressure of choice for the next-generation NASA extravehicular activity (EVA) pressure suit. Thirty-one volunteer subjects, performing light work characteristic of EVA, were exposed to 8.3 psia pressure altitude for six hours. Limb bends incidence was 3.2 percent, and 25.8 percent of the subjects demonstrated significant intravascular bubbling. Those who bubbled were significantly older than the bubble-free group, but differed in no other aspect. An 8.3 psia advanced pressure suit design was considered insufficient to totally preclude the risk of decompression sickness.

Smead, Kenneth W.↗