Systematics in the Electron Spectrum Measured by ATIC

An analysis of different parameters to separate electrons from protons in the ATIC experiment has been performed. Five separate discriminants were studied by different Monte Carlo programs, leading to a variety of results. Application to the ATIC data indicates the range of variation possible in the interpretation of the data. The results of this analysis, when compared with the published results [5], show good agreement in the most interesting region of energy (from 90 GeV to 600 GeV). The measured electron spectrum is compared with the recent data reported by Fermi/LAT, and there is no major disagreement between ATIC s results and Fermi/LAT. Finally, possible systematics-free, short energy scale features of the ATIC electron spectrum are mentioned. Keywords: ATIC, electron spectrum, fine structure

Panov, A. D.

Determining the Detection Efficiency and Background Level of ATIC Electron Observation from Flight Data

Observations of Cosmic-ray electrons are difficult due to the large flux of cosmic ray hadrons. The event selection efficiency and background levels can be estimated from flight data for the ATIC instrument. This reduces the dependence upon Monte Carlo simulations, which show differences between different codes, thereby reducing the systematic errors resulting from analyses that only use simulations. This paper discusses some of the methods used in the ATIC analysis to determine the detection efficiency and background level for the flight data.

Chang, J.

Observations of High Energy Cosmic Ray Electrons by the ATIC Balloon Experiment

Recently the Advanced Thin Ionization Calorimeter (ATIC) balloon experiment reported observations of high energy cosmic ray electrons over the energy range 300 to 800 GeV, indicating a feature or "bump" in the otherwise smoothly decreasing energy spectrum. The severe energy losses that occur as these high energy particles traverse the galaxy render the cosmic ray electron spectrum sensitive to local (a few kiloparsecs) sources and hence very interesting. The ATIC results are the first time that such a cosmic ray spectrum anomaly has been observed at high energy. Potential sources of this electron excess include pulsars, microquasars, supernovae remnants as well as the annihilation of exotic dark matter candidate particles. ATIC has had three successful high altitude flights over the continent of Antarctica 2000-2001, 2002-2003 and 2007-2008. Only results from the first two flights have been reported so far. During this talk we will discuss the ATIC experiment, the electron observations (including preliminary results from the most recent ATIC flight), examine the merits of the various source models and compare the ATIC observations with other recent measurements.

Guzik, T. G.

The Cosmic Ray Electron Excess

This slide presentation reviews the possible sources for the apparent excess of Cosmic Ray Electrons. The presentation reviews the Advanced Thin Ionization Calorimeter (ATIC) instrument, the various parts, how cosmic ray electrons are measured, and shows graphs that review the results of the ATIC instrument measurement. A review of Cosmic Ray Electrons models is explored, along with the source candidates. Scenarios for the excess are reviewed: Supernova remnants (SNR) Pulsar Wind nebulae, or Microquasars. Each of these has some problem that mitigates the argument. The last possibility discussed is Dark Matter. The Anti-Matter Exploration and Light-nuclei Astrophysics (PAMELA) mission is to search for evidence of annihilations of dark matter particles, to search for anti-nuclei, to test cosmic-ray propagation models, and to measure electron and positron spectra. There are slides explaining the results of Pamela and how to compare these with those of the ATIC experiment. Dark matter annihilation is then reviewed, which represent two types of dark matter: Neutralinos, and kaluza-Kline (KK) particles, which are next explained. The future astrophysical measurements, those from GLAST LAT, the Alpha Magnetic Spectrometer (AMS), and HEPCAT are reviewed, in light of assisting in finding an explanation for the observed excess. Also the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) could help by revealing if there are extra dimensions.

Chang, J.

Relative Abundances of Cosmic Ray Nuclei B-C-N-O in the Energy Region from 10 GeV/n to 300 GeV/n. Results from the Science Flight of the ATIC

The ATIC balloon-borne experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germanate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was essentially improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as an additional charge detector together with the silicon matrix. The flux ratios of nuclei B/C, O/C, N/C in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented. The results are compared with existing theoretical predictions.

Panov, A. D.

Revised Energy Spectra for Primary Elements, H - Si, above 50 GeV from the ATIC-2 Science Flight

The Advanced Thin Ionization Calorimeter (ATIC) long duration balloon experiment had a successful science flight accumulating 18 days of data (12/02 - 1/03) during a single circumnavigation in Antarctica. ATIC measures the energy spectra of elements from H to Fe in primary cosmic rays using a fully active Bismuth Germanate calorimeter preceded by a carbon target, with embedded scintillator hodoscopes, and a silicon matrix charge detector at the top. Preliminary results from ATIC have been reported in previous conferences. The revised results reported here are derived from a new analysis of the data with improved charge resolution, lower background and revised energy calibration. The raw energy deposit spectra are de-convolved into primary energy spectra and extrapolated to the top of the atmosphere. We compare these revised results to previous data and comment upon the astrophysical interpretation of the results.

Wefel, J. P.

A Neutron Detector for the Electron Calorimeter (ECAL) Long Duration Balloon Experiment

The highest energy measurements of cosmic ray electrons extend just beyond 1 TeV. High energy electrons are of particular interest because energy losses during interstellar propagation insure that they arrive primarily from nearby sources. This may produce observable structure in their spectrum. Further, it is predicted that electrons and positrons result from the annihilation of many exotic particles deposited as dark matter candidates. These electrons may appear as excesses in the cosmic ray electron spectrum from 200 GeV to 1000 GeV. A new long duration balloon experiment, ECAL, is being planned to provide direct cosmic ray electron measurements from approx.50 GeV to >1 TeV. To make these measurements ECAL must discriminate strongly against showers from protons and heavier ions. One of the techniques used to make this discrimination may be based on measuring the secondary neutrons produced by events in the instrument. The neutron detector configuration and technique will be discussed along with its expected performance based on Monte Carlo simulations.

Adams, J. H., Jr.

All-Particle Spectrum Measured by the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC), a balloon-borne experiment, is designed to investigate the composition and energy spectra of cosmic rays of charge Z = 1 to 26 over the energy range - 10(exp 11) - 10(exp 14) ev. The instrument consists of a silicon matrix charge detector, plastic-scintillator strip hodoscopes interleaved with graphite interaction targets, and an 18 radiation length deep, fully active bismuth germanate (BGO) calorimeter. ATIC has had two successful long duration balloon (LDB) flights launched from McMurdo Station, Antarc't'ica in 2000 and 2002. In this paper, we present the all-particle spectrum extracted from data collected during the ATIC flights, and compare it with results from other experiments at both lower and higher energies.

Ahn, H. S.

Relative Fluxes of Primary Particles in B-C-N-O Group from the ATIC Experiment (Science Flight)

The ATIC balloon-born experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germinate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as charge detector together with silicon matrix. Relative fluxes of nuclei B, C, N, O in the energy region from about 20 GeV/nucleon to 200 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented.

Panov, A. D.

Energy Spectra of H and He from the ATIC-2 Experiment

The Advanced Thin Ionization Calorimeter (ATIC) experiment measures the energy spectra of individual elements, from H to Fe, in the energy region from about 100 GeV to tens of TeV. The ATIC instrument was flown twice in long-duration balloon flights around the South Pole in 2000-2001 (ATIC-1) and 2002-2003 (ATIC-2). ATIC-2 gathered about 18 days of data at an altitude of 36 km. In this paper we discuss the separation of protons from helium and present preliminary energy spectrum of each component, including deconvolution of the measured energy deposit spectra. The results are compared to previous data and to different cosmic ray propagation models, including a diffusion model with weak re-acceleration.

Wefel, J. P.

The ATIC Science Flight in 2002-03: Description and Preliminary Results

The Advanced Thin Ionization Calorimeter (ATIC) balloon experiment completed a 19.7 day science flight, 29 Dec. 02 to 18 Jan. 03, from McMurdo, Antarctica, yielding 65 Gbytes of science data. The instrument was fully recovered just over the trans-Antarctic mountain range. ATIC is designed to make new measurements of the composition and energy spectra of cosmic rays in the region up to 100 TeV total energy. The flight and the instrument performance are described and compared to the ATIC-1 flight from 2000-01. Although the data from this new flight will not be fully processed and analyzed, some preliminary results are discussed.

Wefel, J. P.

Performance of the Advanced Thin Ionization Calorimeter (ATIC)

The ATIC instrument is a balloon-borne experiment capable of measuring cosmic ray elemental spectra from 50 GeV to 100 TeV for nuclei from H to Fe with a fully active Bismuth Germanate calorimeter. Several Long Duration Balloon flights from McMurdo station, Antarctica are scheduled. The detector was tested with high energy electron, proton, and pion beams at CERN. We present results for 150 and 375 GeV protons, and 150 GeV pions and comparison with a GEANT Monte Carlo.

Case, G.

First Flight of the Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment

The ATILT instrument is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range -10 GeV - 100 TeV. ATIC was launched as a long duration test balloon flight on 12/28/00 local time from McMurdo, Antarctica. The operations preceding and during launch went very smoothly. During the first -20 hr while the instrument remained within line of sight (LOS), a full system check out was conducted, the experiment was operated in several test configurations, and all major tuning was completed. Preliminary analysis of the science data indicates that the overall detector system is functioning as expected. With our fully functioning analysis software we were able to monitor the data in nearly real time. Each event was reconstructed event-by-event to confirm the detector performance. The shower profiles indicate that the shower maximum location is deeper in the calorimeter for higher energy events, as expected. The energy spectra of protons, Helium nuclei, and "all particles" appear to follow power laws. Both the Si matrix and top scintillator layer of the charge module show clear charge separation for p and He. As the statistics increase, heavy nuclei charge separation will be evaluated. We will present preliminary results of the LOS data, as well as other data that will be available from the flight-data hard disk,

Case, G.

The ATIC Experiment: First Balloon Flight

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its maiden, test, flight from McMurdo, Antarctica 28/12/00 to 13/01/01, local time, recording over 360 hours of data. ATIC was designed to measure the composition and energy spectra of cosmic rays from approximately 10 GeV to near 100 TeV utilizing a Si-matrix detector to determine charge in conjunction with a scintillator hodoscope which measures charge and trajectory. Cosmic rays that interact in a Carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO crystals. ATIC's geometry factor is about 0.25 m**2-sr. During line-of-sight operations much of the datastream was transmitted to the ground. For most of the flight, the data was recorded on-board, yielding 45 GB of flight data for analysis. The payload construction, operations and in-flight performance are described, along with preliminary results from the on-going analysis.

Wefel, J. P.

The ATIC Experiment: First Balloon Flight

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its maiden test flight from McMurdo, Antarctica 28/12/00 to 13/01/01, local time, recording over 360 hours of data. ATIC was designed to measure the composition and energy spectra of cosmic rays from approx. 10 GeV to near 100 TeV utilizing a Si matrix detector to determine charge in conjunction with a scintillator hodoscope which measures charge and trajectory. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO (Bismuth Germanate) crystals. ATIC's geometry factor is about 0.25 sq. m -sr. During line-of-sight operations much of the datastream was transmitted to the ground. For most of the flight, the data was recorded on-board, yielding 45 GB of flight data for analysis. The payload construction, operations and in-flight performance are described, along with preliminary results from the on-going analysis.

Wefel, J. P.

Automated Track Recognition and Event Reconstruction in Nuclear Emulsion

The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.

Deines-Jones, P.

High-Multiplicity Lead-Lead Interactions at 158 GeV/c per nucleon

The Krakow-Louisiana-Minnesota-Moscow Collaboration (KLMM) has exposed a set of emulsion chambers with lead targets to a 158 GeV/c per nucleon beam of Pb-208 nuclei, and we report the initial analysis of 40 high-multiplicity Pb-Pb collisions. To test the validity of the superposition model of nucleus-nucleus interactions in this new regime, we compare the shapes of the pseudorapidity distributions with FRITIOF Monte Carlo model calculations, and find close agreement for even the most central events. We characterize head-on collisions as having a mean multiplicity of 1550 +/- 120 and a peak pseudorapidity density of 390 +/- 30. These estimates are significantly lower than our FRITIOF calculations.

Deines-Jones, P.

Cosmic ray heavy ion penetration deep into the magnetosphere: Results from S81-1 and CRRES

In spite of strong magnetic shielding by the geomagnetic field, small fractions (1-10 %) of the total high energy, heavy ion intensities of solar and galactic cosmic rays have been observed at energies below theoretical cutoffs for direct entry into the earth's magnetosphere from interplanetary space. We report on measurements of these heavy ions at 10 to 500 MeV/nucleon by cosmic ray composition experiments on the S81-1 satellite in polar orbit during 1982 and on the Combined Release and Radiation Effects Satellite (CRRES) satellite in geosynchronous transfer orbit during 1990-1991.