Search NASASearch

Engineering topics

Wei, Max

Publications and source records attributed to Wei, Max.

Corrigendum to “Cool Rooms for Indoor Heat Resilience: Evaluating Affordable Cooling Strategies in Heat-Stressed California Homes” [Building and Environment 287 (2026) 113877]

The authors regret an error in the acknowledgments section regarding the U.S. Department of Energy Solar Energy Technologies Office award number. The previously listed grant number, 2597–1625, was incorrect. The corrected acknowledgment should read: “This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technologies of the United States Department of Energy (DOE), under Contract No. DE-AC02–05CH11231. This material is based upon work supported by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE00040384. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Department of Energy.” The authors would like to apologise for any inconvenience caused.

Malik, Jeetika

Mapping heat vulnerability in cities: A tale of two california cities

Extreme heat is a major cause of weather-related deaths in the United States. To address this, a heat vulnerability index (HVI) is crucial for assessing heat risk and identifying vulnerable urban areas and populations, supporting city planning and emergency response. Current HVI studies often use Principal Component Analysis (PCA) on environmental, socioeconomic, and medical data to aggregate vulnerability indicators into a single index. However, these fixed aggregation weights struggle to adapt to different use cases, which may require varying focuses. Moreover, existing tools primarily consider outdoor heat exposure, providing an incomplete picture of actual exposure, as people spend most of their time indoors. Our research introduces an HVI web mapping tool that addresses these gaps in the literature by: (1) allowing flexible weights to adapt to different use cases, and (2) uniquely integrating both outdoor and indoor heat exposure by considering building characteristics for a more comprehensive risk assessment. We demonstrated this tool in two California cities with contrasting climates: Fresno (inland, arid, hot summers) and Oakland (temperate coastal). This HVI mapping tool provides essential decision support for policymakers and stakeholders in both short-term heat mitigation and long-term urban planning for building interventions and infrastructure development.

BES

Benefits and challenges in deployment of low global warming potential R290 refrigerant for room air conditioning equipment in California

High global warming potential gases (“high GWP”) are the fastest growing sector of greenhouse gas emissions in the world and in California and are primarily used as refrigerant gases in refrigeration and cooling equipment. Hydrofluorocarbons (HFCs) refrigerants are the dominant type of high GWP gases with GWP values thousands of times larger than CO 2 on a 100-year timescale. Refrigerant-grade propane (“R290”) has a very low GWP (GWP = 3.3) with good thermodynamic properties and good cooling equipment performance but the flammability of any leaked refrigerant makes equipment design, handling, and maintenance critical factors to manage. This paper focuses on the potential climate benefits and costs of transitioning to R290 refrigerant in small room air conditioning (AC) units, specifically window AC, packaged terminal AC/heat pumps (PTAC/PTHP), and mini-split heat pumps. Overall climate impact for a transition to all three types of air conditioning units in the 2022–2051 timeframe is found to be from 15 to 64 million metric tons of greenhouse gas (GHG) savings in California with a cost of saved CO 2 eq that ranges from $14.50 per ton of CO 2 eq saved to -$50.30 per ton of CO 2 eq saved (net savings) depending on whether the baseline refrigerant is R32 or R410A and depending on the relative energy efficiency for R290 units compared to baseline units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI