SU-F-T-347: An Absolute Dose-Volume Constraint Based Deterministic Optimization Framework for Multi-Co60 Source Focused Radiotherapy

Purpose: Treatment plan optimization in multi-Co60 source focused radiotherapy with multiple isocenters is challenging, because dose distribution is normalized to maximum dose during optimization and evaluation. The objective functions are traditionally defined based on relative dosimetric distribution. This study presents an alternative absolute dose-volume constraint (ADC) based deterministic optimization framework (ADC-DOF). Methods: The initial isocenters are placed on the eroded target surface. Collimator size is chosen based on the area of 2D contour on corresponding axial slice. The isocenter spacing is determined by adjacent collimator sizes. The weights are optimized by minimizing the deviation from ADCs using the steepest descent technique. An iterative procedure is developed to reduce the number of isocenters, where the isocenter with lowest weight is removed without affecting plan quality. The ADC-DOF is compared with the genetic algorithm (GA) using the same arbitrary shaped target (254cc), with a 15mm margin ring structure representing normal tissues. Results: For ADC-DOF, the ADCs imposed on target and ring are (D100>10Gy, D50,10, 0<12Gy, 15Gy and 20Gy) and (D40<10Gy). The resulting D100, 50, 10, 0 and D40 are (9.9Gy, 12.0Gy, 14.1Gy and 16.2Gy) and (10.2Gy). The objectives of GA are to maximize 50% isodose target coverage (TC) while minimize the dose delivered to the ring structure, which results in 97% TC and 47.2% average dose in ring structure. For ADC-DOF (GA) techniques, 20 out of 38 (10 out of 12) initial isocenters are used in the final plan, and the computation time is 8.7s (412.2s) on an i5 computer. Conclusion: We have developed a new optimization technique using ADC and deterministic optimization. Compared with GA, ADC-DOF uses more isocenters but is faster and more robust, and achieves a better conformity. For future work, we will focus on developing a more effective mechanism for initial isocenter determination.

60 APPLIED LIFE SCIENCES↗

SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-08: LINAC Head Geometry Modeling for Cyber Knife System

Purpose: Knowledge of the LINAC head information is critical for model based dose calculation algorithms. However, the geometries are difficult to measure precisely. The purpose of this study is to develop linac head models for Cyber Knife system (CKS). Methods: For CKS, the commissioning data were measured in water at 800mm SAD. The measured full width at half maximum (FWHM) for each cone was found greater than the nominal value, this was further confirmed by additional film measurement in air. Diameter correction, cone shift and source shift models (DCM, CSM and SSM) are proposed to account for the differences. In DCM, a cone-specific correction is applied. For CSM and SSM, a single shift is applied to the cone or source physical position. All three models were validated with an in-house developed pencil beam dose calculation algorithm, and further evaluated by the collimator scatter factor (Sc) correction. Results: The mean square error (MSE) between nominal diameter and the FWHM derived from commissioning data and in-air measurement are 0.54mm and 0.44mm, with the discrepancy increasing with cone size. Optimal shift for CSM and SSM is found to be 9mm upward and 18mm downward, respectively. The MSE in FWHM is reduced to 0.04mm and 0.14mm for DCM and CSM (SSM). Both DCM and CSM result in the same set of Sc values. Combining all cones at SAD 600–1000mm, the average deviation from 1 in Sc of DCM (CSM) and SSM is 2.6% and 2.2%, and reduced to 0.9% and 0.7% for the cones with diameter greater than 15mm. Conclusion: We developed three geometrical models for CKS. All models can handle the discrepancy between vendor specifications and commissioning data. And SSM has the best performance for Sc correction. The study also validated that a point source can be used in CKS dose calculation algorithms.

60 APPLIED LIFE SCIENCES↗

SU-C-210-06: Quantitative Evaluation of Dosimetric Effects Resulting From Positional Variations of Pancreatic Tumor Volumes

Purpose: The aim of this study is to quantify dosimetric effects resulting from variation in pancreatic tumor position assessed by bony anatomy and implanted fiducial markers Methods: Twelve pancreatic cancer patients were retrospectively analyzed for this study. All patients received modulated arc therapy (VMAT) treatment using fiducial-based Image Guided Radiation Therapy (IGRT) to the intact pancreas. Using daily orthogonal kV and/or Cone beam CT images, the shift needed to co-register the daily pre-treatment images to reference CT from fiducial to bone (Fid-Bone) were recorded as Left-Right (LR), Anterior-Posterior (AP) and Superior-Inferior (SI). The original VMAT plan iso-center was shifted based on KV bone matching positions at 5 evenly spaced fractions. Dose coverage of the planning target volumes (PTVs) (V100%), mean dose to liver, kidney and stomach/duodenum were assessed in the modified plans. Results: A total of 306 fractions were analyzed. The absolute fiducial-bone positional shifts were greatest in the SI direction, (AP = 2.7 ± 3.0, LR = 2.8 ± 2.8, and SI 6.3 ± 7.9 mm, mean ± SD). The V100% was significantly reduced by 13.5%, (Fid-Bone = 95.3 ± 2.0 vs. 82.3 ± 11.8%, p=0.02). This varied widely among patients (Fid-Bone V100% Range = 2–60%), where 33% of patients had a reduction in V100% of more than 10%. The impact on OARs was greatest to the liver (Fid-Bone= 14.6 vs. 16.1 Gy, 10%), and stomach, (Fid-Bone = 23.9 vx. 25.5 Gy, 7%), however was not statistically significant (p=0.10 both). Conclusion: Compared to matching by fiducial markers, matching by bony anatomy would have substantially reduced the PTV coverage by 13.5%. This reinforces the importance of online position verification based on fiducial markers. Hence, implantation of fiducial markers is strongly recommended for pancreatic cancer patients undergoing intensity modulated radiation therapy treatments.

60 APPLIED LIFE SCIENCES↗

SU-E-J-17: Intra-Fractional Prostate Movement Correction During Treatment Delivery Period for Prostate Cancer Using the Intra-Fractional Orthogonal KV-MV Image Pairs

Purpose: To evaluate the intra-fractional prostate movement range during the beam delivery and implement new IGRT method to correct the prostate movement during the hypofractionated prostate treatment delivery. Methods: To evaluate the prostate internal motion range during the beam delivery, 11 conventional treatments were utilized. Two-arc RapidArc plans were used for the treatment delivery. Orthogonal KV imaging is performed in the middle of the treatment to correct intra-fractional prostate movement. However, it takes gantry-mounted on-board imaging system relative long time to finish the orthogonal KV imaging because of gantry rotation. To avoid gantry movement and accelerate the IGRT processing time, orthogonal KV-MV image pair is tested using the OBI daily QA Cube phantom. Results: The average prostate movement between two orthogonal KV image pairs was 0.38cm (0.20cm ∼ 0.85cm). And the interval time between them was 6.71 min (4.64min ∼ 9.22 min). 2-arc beam delivery time is within 3 minutes for conventional RapidArc treatment delivery. Hypofractionated treatment or SBRT need 4 partial arc and possible non-coplanar technology, which need much longer beam delivery time. Therefore prostate movement might be larger. New orthogonal KV-MV image pair is a new method to correct the prostate movement in the middle of the beam delivery if real time tracking method is not available. Orthogonal KV-MV image pair doesn’t need gantry rotation. Images were acquired quickly which minimized possible new prostate movement. Therefore orthogonal KV-MV image pair is feasible for IGRT. Conclusion: Hypofractionated prostate treatment with less PTV margin always needs longer beam delivery time. Therefore prostate movement correction during the treatment delivery is critical. Orthogonal KV-MV imaging pair is efficient and accurate to correct the prostate movement during treatment beam delivery. Due to limited fraction number and high dose per fraction, the MV imaging dose is negligible.

60 APPLIED LIFE SCIENCES↗

Glauber-based evaluations of the odd moments of the initial eccentricity relative to the even order participant plates

Monte Carlo simulations are used to compute the centrality dependence of the odd moments of the initial eccentricity {var_epsilon}{sub n+1}, relative to the even-order (n) participant planes {Psi}{sub n} in Au + Au collisions. The results obtained for two models of the eccentricity - the Glauber and the factorized Kharzeev-Levin-Nardi (fKLN) models - indicate magnitudes which are essentially zero. They suggest that a possible correlation between the orientations of the odd and even participant planes ({Psi}{sub n+1} and {Psi}{sub n}, respectively) does not have a significant influence on the calculated eccentricities. An experimental verification test for correlations between the orientations of the odd and even participant planes is also proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial eccentricity fluctuations and their relation to higher-order flow harmonics

Monte Carlo simulations are used to compute the centrality dependence of the participant eccentricities ({var_epsilon}{sub n}) in Au+Au collisions for the two primary models currently employed for eccentricity estimates - the Glauber and the factorized Kharzeev-Levin-Nardi (fKLN) models. They suggest specific testable predictions for the magnitude and centrality dependence of the flow coefficients v{sub n}, respectively measured relative to the event planes {Psi}{sub n}. They also indicate that the ratios of several of these coefficients may provide an additional constraint for distinguishing between the models. Such a constraint could be important for a more precise determination of the specific viscosity of the matter produced in heavy ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dissecting the role of initial collision geometry for jet quenching observables in relativistic heavy ion collisions

The observation of large azimuthal anisotropy or v{sub 2} for hadrons above p{sub T} > 5 GeV/c in Au+Au collisions at {radical}s{sub nn} = 200 GeV has been a longstanding challenge for jet quenching models based on perturbative QCD (pQCD). Using a simple jet absorption model, we seek to clarify the situation by exploring in detail how the calculated v{sub 2} varies with choices of the collision geometry as well as choices of the path length dependence and thermalization time {tau}{sub 0} in the energy loss formula. Besides the change of eccentricity due to distortion from gluon saturation or event-by-event fluctuation, we find that the v{sub 2} is also sensitive to the centrality dependence of multiplicity and the relative size between the matter profile and the jet profile. We find that the v{sub 2} calculated for the naive quadratic path length dependence of energy loss, even including eccentricity fluctuation and the gluon saturation, is not enough to describe the experimental data at high p{sub T} ({approx} 6 GeV/c) in Au+Au collisions. However, it can match the full centrality dependence of v{sub 2} data if higher power path length dependence of energy loss is allowed. We also find that the calculated v{sub 2} is sensitive to the assumption of the early time dynamics but generally increases with {tau}{sub 0}, opposite to what one expects for elliptic flow. This study attests to the importance of confining the initial geometry, possibly by combining jet quenching v{sub 2} with elliptic flow and other jet quenching observables, for proper interpretation of the experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of acicular ferrite formation on grain refinement in the coarse-grained region of heat-affected zone

The microstructure of acicular ferrite and its formation for the grain refinement of coarse-grained region of heat-affected zone of high strength low-alloy bainite steels were studied using three-dimensional reconstruction technique. Crystallographic grain size was analyzed by means of electron backscatter diffraction. It was revealed that the microstructure in the coarse-grained region of the heat-affected zone consisted of predominantly bainite packets and a small proportion of acicular ferrite. Acicular ferrite was of lath or plate-like rather than needle or rod-like morphology. Tempering of the coarse-grained region of heat-affected zone showed that the acicular ferrite was more stable than the bainite, indicating that the acicular ferrite was formed prior to bainite. The acicular ferrite laths or plates divided the prior austenite grains into smaller and separate regions, and confining the bainite transformed at lower temperatures in the smaller regions and hence leading to the grain refinement in the coarse-grained region of the heat-affected zone.

36 MATERIALS SCIENCE↗

Constraints on models for the initial collision geometry in ultrarelativistic heavy ion collisions

Monte Carlo simulations are used to compute the centrality dependence of the collision zone eccentricities (epsilon{sub 2,4}), for both spherical and deformed ground state nuclei, for different model scenarios. Sizable model dependent differences are observed. They indicate that measurements of the second and fourth order Fourier flow coefficients v{sub 2,4}, expressed as the ratio (v{sub 4}/(v{sub 2}){sup 2}), can provide robust constraints for distinguishing between different theoretical models for the initial-state eccentricity. Such constraints could remove one of the largest impediments to a more precise determination of the specific viscosity from precision v{sub 2,4} measurements at the Relativistic Heavy Ion Collider (RHIC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy Loss for Heavy Quarks in Relation to Light Partons: Is Radiative Energy Loss for Heavy Quarks Anomalous?

The scaling properties of jet-suppression measurements are compared for nonphotonic electrons (e{sup +}-) and neutral pions (pi{sup 0}) in Au+Au collisions at sq root(s{sub NN})=200 GeV. For a broad range of transverse momenta and collision centralities, the comparison is consistent with jet quenching dominated by radiative energy loss for both heavy and light partons. Less quenching is indicated for heavy quarks via e{sup +}-; this gives an independent estimate of the transport coefficient q-circumflex that agrees with its magnitude obtained from quenching of light partons via pi{sup 0}'s.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Away-Side Asymmetry of Jet Correlation Relative to the Reaction Plane:A Sensitive Probe for Jet In-Medium Modifications

We proposed a new observable based on two particle azimuth correlation to study the away-side medium response in mid-central Au+Au collisions. We argue that a left/right asymmetry may appear at the away-side by selecting triggers separately in the left and right side of the reaction plane. A simple model estimation suggests that the magnitude of such asymmetry could reach 30% with details depends on the medium response mechanisms. This asymmetry, if observed, can help to distinguish competing theoretical models.

99 GENERAL AND MISCELLANEOUS↗