Search NASA⌕ Search

Engineering topics

Wei, T. Y. C.

Publications and source records attributed to Wei, T. Y. C..

Generation IV nuclear energy system initiative; air-cooled option RCCS studies and NSTF preparation

The Reactor Cavity Cooling System (RCCS) is an important system to the passive safety case being incorporated in the overall safety strategy for the Next Generation Nuclear Plant (NGNP). The RCCS will be one of the new safety systems specifically designed for the next generation of nuclear power plants. In particular, it is being developed and incorporated into the proposed reactor and plant designs for the very high temperature reactor (VHTR)—a helium gas cooled nuclear plant with a thermal-spectrum reactor. The RCCS forms a passive heat sink external to the reactor, and is located within the reactor cavity/silo surrounding the metal vessel. During emergency accident conditions when all ac (alternating current) power is lost, natural convection of the RCCS coolant removes the heat radiated or naturally convected from the metal vessel wall to the inner boundary of the RCCS facing the vessel. RCCS will be a first-of-a-kind (FOAK) passive safety system for core decay heat removal when the FOAK VHTR is built.

Lomperski, S.↗

AFR-100 safety analyses

The Advanced Fast Reactor-100 (AFR-100) is Argonne National Laboratory's 250 MWth metal-fueled modular sodium-cooled pool-type fast reactor concept. [1] A series of accident sequences that focused on the AFR-100's ability to provide protection against reactor damage during low probability accident sequences resulting from multiple equipment failures were examined. Protected and Unprotected Loss of Flow (PLOF and ULOF) and Unprotected Transient Over-Power (UTOP) accidents were simulated using the SAS4A/SASSYS-1 safety analysis code. The large heat capacity of the sodium in the pool-type reactor allows the AFR-100 to absorb large amounts of energy during a PLOF with relatively small temperature increases throughout the system. During a ULOF with a 25-second flow halving time, coolant and cladding temperatures peak around 720 deg. C within the first minute before reactivity feedback effects decrease power to match the flow. Core radial expansion and fuel Doppler provide the necessary feedback during the UTOP to bring the system back to critical before system temperatures exceed allowable limits. Simulation results indicate that adequate ULOF safety margins exist for the AFR-100 design with flow halving times of twenty-five seconds. Significant safety margins are maintained for PLOF accidents as well as UTOP accidents if a rod stop is used. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AFR-100 Safety Analyses

Preliminary analyses have been completed to assess the potential safety performance characteristics of the Advanced Fast Reactor (AFR) 250 MWth design. The scope of the analyses presented here focuses on the ability of AFR to provide inherent protection against damaging consequences in low probability accident sequences involving multiple equipment failures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗