Light Output Fitting Software

Light output response of scintillators is crucial to the utilization of organic scintillators as effective tools in radiation detection and measurement. While the response is a continuous distribution, the light output corresponding to the maximum energy deposition is crucial in effectively understanding and simulating a detector. There are a variety of fits derived in literature that will vary for every detector material. The Light Output Response Fitter, or LORF Program is a python script designed to easily and quickly compute and plot fits for a variety of scintillator light output models. It includes a stopping power library constructed from SRIM including Organic Glass, EJ309, EJ301, Stilbene, EJ276, and their deuterated counterparts by default, with the ability for the user to add custom stopping power libraries. The user is also capable of importing the python package and utilizing its in-built functions as appropriate. Uses for this capability include plotting and computing a model with known parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICSBEP Benchmark Template

The purpose of this document is to demonstrate the ability of LATEX to create an ICSBEP benchmark evaluation. Creating a large document in LATEX offers many benefits, such as automatic numbering of items such as tables and figures, and easier placement of objects in the page. Additionally, it is easier to have multiple styles of pages in the same document, and in general the handling of large documents (which evaluations very commonly are) is not problematic. The formatting of this document is meant to conform to both the standards of the document and formatting guide and established practices in order to make the creation of new evaluations a more streamlined process. This will also help reduce the benchmark-to-benchmark variation in style.

97 MATHEMATICS AND COMPUTING↗

Neutron Leakage Spectra of the EUCLID Experiment [Abstract]

Integral experiments with sub-critical and critical configurations of special nuclear material are performed in support of nuclear data validation and adjustment. Different nuclear data evaluations may have different values for individual cross sections due to uncertainties in (or lack of) differential experiments, but compensating errors in these data sets can lead to the same k eff results for one application while vastly different for another application. One example of this is 239 Pu, where both ENDF/B-VIII.0 and JEFF-3.3 correctly compute k eff of the Jezebel critical assembly, but the individual contributions from each reaction are vastly different. To help resolve this specific case, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project used machine learning to design a set of experiments to help resolve the compensating errors in 239 Pu. A total of six responses were measured during the experimental campaign, which constrain the data in ways that k eff alone cannot and will be used for adjustment of the nuclear data. One of these responses is the neutron leakage spectrum, which recent work has shown to be useful for constraining the prompt fission neutron spectrum and inelastic scattering. The neutron leakage spectra were measured utilizing a 3 in. right cylinder EJ-301D detector. The measured signal in the detector was deconvoluted using spectrum unfolding techniques, which are presented and compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗