Search NASASearch

Engineering topics

Wellemeyer, C.

Publications and source records attributed to Wellemeyer, C..

The Updated Umkehr Ozone Retrieval Algorithm and its Validation against Satellite Data

Improvements to the Umkehr ozone profile retrieval algorithm have been developed and are now being evaluated. The updated algorithm is able to simulate observations more accurately and provides data output that is easier to analyze. Among the new diagnostic capabilities that the updated algorithm provides is the averaging kernel (AK) method. The AK approach allows studying how the algorithm responds when a small perturbation is made in a particular layer of the atmosphere [Rodgers 1976, 1990]. We will use the AK method to define precisely what Umkehr should measure given a set of profiles measured by other platforms. This method allows us to compare trends and offsets in data more accurately than it has been done in the past. The updated Umkehr retrievals will be validated against SAGE II ozone profiles as well as SSBUV ozone profile data. We will discuss possible reasons for offset between data and differences in derived ozone profile trends. Considerable variability of the ozone profile within the 10-degree latitude envelope creates noise in the SAGE matching dataset and makes comparisons difficult. To eliminate this problem, the SAGE and Umkehr data had been previously de-seasonalized by subtracting the latitude/season dependent ozone climatology. However, the remaining noise in the ozone residuals was still considerably high for trend analysis and was attributed to longitude variability of SAGE sampling. The new ozone climatology (Labow, NASA) that has longitude dependent ozone variability will be used to minimize contribution of sampling noise in comparisons of satellite and ground station. The comparison of zenith-sky radiances (Umkehr N-value measurements) synthesized for a given set of SAGE profiles will be used to determine whether SAGE-derived N-values agree with the Umkehr-measured N-values. The instrumental effects will be discussed. Both the Umkehr data and SAGE II measurements will be analyzed for their information about ozone variability and loss and recovery rates at the mid- and upper (40 km) levels. The updated long-term Umkehr dataset can be used to provide high quality information for identifying signs of ozone recovery. The long Umkehr historical record can provide additional information for separating the dynamic and chemical mechanisms of depletion, and can help the community better understand climate change effects.

Petropavlovskikh, I.

GOME Total Ozone and Calibration Error Derived Usign Version 8 TOMS Algorithm

The Global Ozone Monitoring Experiment (GOME) is a hyper-spectral satellite instrument measuring the ultraviolet backscatter at relatively high spectral resolution. GOME radiances have been slit averaged to emulate measurements of the Total Ozone Mapping Spectrometer (TOMS) made at discrete wavelengths and processed using the new TOMS Version 8 Ozone Algorithm. Compared to Differential Optical Absorption Spectroscopy (DOAS) techniques based on local structure in the Huggins Bands, the TOMS uses differential absorption between a pair of wavelengths including the local stiucture as well as the background continuum. This makes the TOMS Algorithm more sensitive to ozone, but it also makes the algorithm more sensitive to instrument calibration errors. While calibration adjustments are not needed for the fitting techniques like the DOAS employed in GOME algorithms, some adjustment is necessary when applying the TOMS Algorithm to GOME. Using spectral discrimination at near ultraviolet wavelength channels unabsorbed by ozone, the GOME wavelength dependent calibration drift is estimated and then checked using pair justification. In addition, the day one calibration offset is estimated based on the residuals of the Version 8 TOMS Algorithm. The estimated drift in the 2b detector of GOME is small through the first four years and then increases rapidly to +5% in normalized radiance at 331 nm relative to 385 nm by mid 2000. The lb detector appears to be quite well behaved throughout this time period.

Gleason, J.

New Total Ozone Algorithm for Application to the Total Ozone Mapping Spectrometer

The Total Ozone Mapping Spectrometer (TOMS) series comprises four instruments providing a total of 25 years of daily global stratospheric ozone data over the sunlit portion of the Earth. A new retrieval algorithm has been developed for TOMS, designated Version 8. The algorithm is based on differential absorption across a pair of wavelength channels chosen close together to minimize the impact of wavelength dependent forward modeling errors. Version 8 enhancements include correction for the presence of tropospheric aerosols and sun glint from water surfaces, a better treatment of variability due to tropospheric ozone and temperature dependence, and an improved forward model, particularly in regions of persistent snow and ice. Among other things, the Version 8 enhancements have reduced latitudinal dependence seen previously in TOMS - Dobson comparisons, predominantly in the Southern Hemisphere's summer, when the tropospheric ozone, temperature, and snow/ice corrections are additive. The basic components of the algorithm and its impact on derived total ozone will be discussed.

Wellemeyer, C.

Total Ozone from the Ozone Monitoring System (OMI) using TOMS and DOAS Methods

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to NASA's EOS-Aura satellite scheduled for launch in January 2004. OMI is an imaging spectrometer that will measure the back-scattered Solar radiance in the wavelength range of 270 to 500 nm. The instrument provides near global coverage in one day with a spatial resolution of 13x24 square kilometers. OMI is a new instrument, with a heritage from TOMS, SBW, GOME, GOMOS and SCIAMACHY. OMI'S unique capabilities for measuring important trace gases and aerosols with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will provide data continuity with the 23-year ozone record of TOMS. There are three ozone products planned for OMI: total column ozone, ozone profile and tropospheric column ozone. We are developing two different algorithms for total column ozone: one similar to the algorithm currently being used to process the TOMS data, and the other an improved version of the differential optical absorption spectroscopy (DOAS) method, which has been applied to GOME and SCIAMACHY data. The main reasons for starting with two algorithms for total ozone have to do with heritage and past experience; our long-term goal is to combine the two to develop a more accurate and reliable total ozone product for OMI. We will compare the performance of these two algorithms by applying both of them to the GOME data. We will examine where and how the results differ, and use the extensive TOMS-Dobson comparison studies to assess the performance of the DOAS algorithm.

Veefkind, J. P.

Calibration of TOMS Radiances From Ground Observations

Verification of a stratospheric ozone recovery remains a high priority for environmental research and policy definition. Models predict an ozone recovery at a much lower rate than the measured depletion rate observed to date. Therefore improved precision of the satellite and ground ozone observing systems are required over the long term to verify its recovery. We show that validation of radiances from the ground can be a very effective means for correcting long term drifts of backscatter type satellite measurements and can be used to cross calibrate all BUV instruments in orbit (TOMS, SBUV/2, GOME, SCIAMACHY, OMI, GOME-2, OMPS). This method bypasses the retrieval algorithms used to derive ozone products from both satellite and ground based measurements that are normally used to validate the satellite data. Radiance comparisons employ forward models, but they are inherently more accurate than the retrieval This method employs very accurate comparisons between ground based zenith sicy radiances and satellite nadir radiances and employs two well established capabilities at the Goddard Space Flight Center, 1) the SSBUV calibration facilities and 2) the radiative transfer codes used for the TOMS and SBUV/2 algorithms and their subsequent refinements. The zenith sky observations are made by the SSBUV where its calibration is maintained to a high degree of accuracy and precision. Radiative transfer calculations show that ground based zenith sky and satellite nadir backscatter ultraviolet comparisons can be made very accurately under certain viewing conditions. Initial ground observations taken from Goddard Space Flight Center compared with radiative transfer calculations has indicated the feasibility of this method. The effect of aerosols and varying ozone amounts are considered in the model simulations and the theoretical comparisons. The radiative transfer simulations show that the ground and satellite radiance comparisons can be made with an uncertainty of less than l\% without the knowledge of the amount ozone viewed by either instrument on ground or in space. algorithms.

Bojkov, B. R.

Earth Probe Total Ozone Mapping Spectrometer (TOMS) Data Product User's Guide

Two data products from the Earth Probe Total Ozone Mapping Spectrometer (EP/TOMS) have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The EP/ TOMS began taking measurements on July 15, 1996. The instrument measures backscattered Earth radiance and incoming solar irradiance; their ratio is used in ozone retrievals. Changes in the reflectivity of the solar diffuser used for the irradiance measurement are monitored using a carousel of three diffusers, each exposed to the degrading effects of solar irradiation at different rates. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and the drift is less than 0.5 percent over the first year of data. The Level-2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level-3 product contains daily total ozone and reflectivity in a 1-degree latitude by 1.25 degrees longitude grid. Level-3 files containing estimates of LTVB at the Earth surface and tropospheric aerosol information are also available, Detailed descriptions of both HDF data-files and the CD-ROM product are provided.

McPeters, R.

ADEOS Total Ozone Mapping Spectrometer (TOMS) Data Products User's Guide

Two data products from the Total Ozone Mapping Spectrometer (ADEOS/TOMS) have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The ADEOS/ TOMS began taking measurements on September 11, 1996, and ended on June 29, 1997. The instrument measured backscattered Earth radiance and incoming solar irradiance; their ratio was used in ozone retrievals. Changes in the reflectivity of the solar diffuser used for the irradiance measurement were monitored using a carousel of three diffusers, each exposed to the degrading effects of solar irradiation at different rates. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and the drift is less than 0.5 percent over the 9-month data record. The Level 2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level 3 product contains daily total ozone and reflectivity in a 1-degree latitude by 1.25 degrees longitude grid. The Level 3 files containing estimates of UVB at the Earth surface and tropospheric aerosol information will also be available. Detailed descriptions of both HDF data files and the CDROM product are provided.

Krueger, A.

Application of the Langley plot method to the calibration of the solar backscattered ultraviolet instrument on the Nimbus 7 satellite

The concept of the well-known Langley plot technique, used for the calibration of ground-based instruments, has been generalized for application to satellite instruments. In polar regions, near summer solstice, the solar backscattered ultraviolet (SBUV) instrument on the Nimbus 7 satellite samples the same ozone field at widely different solar zenith angles. These measurements are compared to assess the long-term drift in the instrument calibration. Although the technique provides only a relative wavelength-to-wavelength calibration, it can be combined with existing techniques to determine the drift of the instrument at any wavelength. Using this technique, we have generated a 12-year data set of ozone vertical profiles from SBUV with an estimated accuracy of +/- 5% at 1 mbar and +/- 2% at 10 mbar (95% confidence) over 12 years. Since the method is insensitive to true changes in the atmospheric ozone profile, it can also be used to compare the calibrations of similar SBUV instruments launched without temporal overlap.

Bhartia, P. K.

Calibration of the NOAA 11 solar backscatter ultraviolet (SBUV/2) ozone data set from 1989 to 1993 using in-flight calibration data and SSBUV

Total ozone and ozone profiles are currently being measured by solar backscatter ultraviolet (SBUV/2) instruments onboard NOAA polar orbiting spacecraft using the backscattered ultraviolet technique. The NOAA 11 SBUV/2 operational data set, reprocessed from January 1989 to May 1993 (version 6), includes an updated algorithm and revised prelaunch and postlaunch calibrations of the geometrical albedo observations used to derive ozone values. The postlaunch calibration revisions remove time dependent errors in the ozone amounts due to instrument drift, while the revised prelaunch calibration corrects the absolute value of retrieved ozone. The prelaunch corrections are a result of calibration checks from in-orbit comparisons of ultraviolet geometric albedos measured by shuttle SBUV (SSBUV) and the NOAA 11 SBUV/2. Geometric albedo comparison data are further corrected using a radiative transfer code to account for the small difference in observing conditions between the two spacecraft. The postlaunch corrections rely on in-flight calibration and solar irradiance data to account for time dependent changes in instrument gain, thermal response, and instrument diffuser degradation over time. Comparison of data from three SSBUV flights, which occurred about one year apart, with concurrent SBUV/2 data provided an independent check of the time dependent change derived from the in-flight calibration data. Time independent corrections result in an increase of about 1% for total ozone, 5% for ozone at 1 mbar, and near 0% at 15 mbar. The time dependent corrections amount to an increase of 2% for total ozone, 10% for ozone near 1 mbar, and 3% at 15 mbar at the end of the current record in May 1993. Recent laboratory studies indicate that the absolute radiance calibrations may still be in error by a few percent which results in ozone profile values that are too low. The SBUV/2 total and ozone profile data are compared to the Nimbus SBUV data during the period when the data overlapped. Total ozone values agree to about 1%, while ozone profile differences range from -4% to +6%, depending on latitude and altitude, relative to SBUV. These differences are not statistically significant given the uncertainties of the two data sets.

Hilsenrath, E.

Global ozone data from the meteor-3/TOMS ultraviolet spectrometer

A new TOMS instrument (Total Ozone Mapping Spectrometer) was launched from the Plesetsk Cosomodrome, Russia on August 15, 1991. The purpose of the joint project between the U.S. and Russia was to continue the long-term record of ozone measurements from Nimbus-7/TOMS (launched in October 1978). Ozone data from the two satellites compare very closely. When the orbital positions were nearly the same, the comparison over the entire globe showed an offset of 2 percent with a standard deviation of 5 percent. Comparisons were made with several ground based M124 and Dobson stations showing good agreement in absolute value and with the day-to-day variations seen by the ground stations.

Herman, J. R.

A new method for monitoring long term calibration of the SBUV and TOMS instruments

A new method has been developed to monitor the long-term calibration of the Solar Backscatter Ultraviolet (SBUV) and Total Ozone Mapping Spectrometer (TOMS) instruments. It is based on the fact that the radiance in one channel can be expressed as a linear sum of the radiances in neighboring channels. Using simulated radiances for the SBUV and TOMS instruments, various scenarios of changes in instrument calibration are investigated. Results from sample processing of SBUV data are also presented.

Ahmad, Z.

Estimation of errors in the TOMS total ozone measurement during the Antarctica ozone campaign of August/September 1987

The Total Ozone Mapping Spectrometer (TOMS) instrument on the Nimbus-7 satellite provides the primary source of total ozone data for the study of total ozone in the polar regions of the earth. There are two types of instrument related errors: a slowly developing drift in the instrument calibration since the launch of the instrument in October 1978 and an increase in the measurement noise beginning April, 1984. It is estimated that by October 1987, the accumulated error in the TOMS total ozone measurement due to instrument drift is about 6 m-atm-cm. The sign of the error is such that the TOMS is slightly overpredicting the long-term decrease of the Antarctica ozone. The increase in the measurement noise is more difficult to quantify, affecting some measurements by as much as 10 D.U. and others not at all. A detailed analysis of this error and its potential impact on the studies of total ozone from TOMS will be provided. There are three categories of algorithmic errors: (1) error due the unusual shape of the ozone profile in the ozone hole; (2) error caused by very low atmospheric temperatures in the ozone hole affecting the ozone absorption cross-sections at the TOMS wavelengths; and (3) errors resulting from occasionally thick stratospheric clouds that sometimes reach to 20 km in the ozone hole.

Bhartia, P. K.

User's guide for SBUV/TOMS ozone derivative products

A series of products are available derived from the total-ozone and ozone vertical profile results for the Solar Backscattered Ultraviolet/Total-Ozone Mapping Spectrometer (SBUV/TOMS) Nimbus-7 operation. Products available are (1) orbital height-latitude cross sections of the SBUV profile data, (2) daily global total ozone contours in polar coordinates, (3) daily averages of total ozone in global 5x5 degree latitude-longitude grid, (4) daily, monthly and quarterly averages of total ozone and profile data in 10 degree latitude zones, (5) tabular presentation of zonal means, (6) daily global total ozone and profile contours in polar coordinates. The ""Derivative Products User's Guide'' describes each of these products in detail, including their derivation and presentation format. Information is provided on how to order the tapes and microfilm from the National Space Science Data Center.

Fleig, A. J.