Search NASA⌕ Search

Engineering topics

Wells, L.

Publications and source records attributed to Wells, L..

Constellation's best estimate alternate source term methodology overview

Safety analyses for a nuclear power plants need to consider postulated accidents that results in at risk of accidental release of radiation. The regulations require plant specific safety analysis reports to include an evaluation of the requirements of 10CFR50.67. Such a safety analysis report mandates limits such that calculated radiological consequences relative to certain dose locations do not exceed a total effective dose equivalent (TEDE) limits following a postulated release of radioactivity. Calculations are performed to estimate the radiological consequences, in terms of dose, to people and equipment to ensure the estimated doses are within the prescribed limits. Analysis should demonstrate, with reasonable assurance, that these prescribed limits are complied with. Conventional methodologies utilize conservative approaches to address lack of uncertainty quantification in the utilized approaches, methods, and/or inputs. These built-in excess conservatisms often result in compounding effects and hence overly conservative results in the estimated radiological consequences, which leads to inaccurate margin evaluation for operation and accident mitigation. Therefore, evaluating accurate dose consequences is needed for both operational and safety reasons. The research documented in this paper provides an overview of Constellation's Best Estimate Alternate Source Term (BEAST) Methodology. BEAST methodology relies upon the use of realistic yet bounding input distributions for key analysis parameters, which replaces use of conservative deterministic singular inputs that bound overall analysis domain. This approach enables evaluating a more accurate accident analysis response, while enabling a bounding licensing basis envelope via more accurate quantification of uncertainty in the application. Therefore, built-in margin for a given scenario is more accurately evaluated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of Constellation's best estimate alternate source term methodology

Safety analyses for a nuclear power plants need to consider postulated accidents that results in a risk of accidental release of radiation. The regulations require plant specific safety analysis reports to include an evaluation of the requirements of 10CFR50.67. Such a safety analysis report mandates limits such that calculated radiological consequences at certain locations do not exceed established limits in 10CFR50.67 following a postulated release of radioactivity. Analyses should demonstrate, with reasonable assurance, that these prescribed limits are complied with. Conventional methodologies utilize conservative approaches to address lack of uncertainty quantification in the utilized approaches, methods, and/or inputs. These built-in excess conservatisms often result in with compounding effects and hence overly conservative results in the estimated radiological consequences, which leads to inaccurate margin evaluation for operation and accident mitigation. Therefore, evaluating accurate dose consequences is needed for both operational and safety reasons. This paper illustrates the use of the best estimate source term (BEAST) methodology to the case of the loss of coolant accident (LOCA) dose analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Comparison of Wind Speed Data from Mechanical and Ultrasonic Anemometers

This study compared the performance of mechanical and ultrasonic anemometers at the Eastern Range (ER; Kennedy Space Center and Cape Canaveral Air Force Station on Florida's Atlantic coast) and the Western Range (WR; Vandenberg Air Force Base on California's Pacific coast). Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at the ER and WR for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The current ER and WR weather tower wind instruments are being changed from the current propeller-and-vane (ER) and cup-and-vane (WR) sensors to ultrasonic sensors through the Range Standardization and Automation (RSA) program. The differences between mechanical and ultrasonic techniques have been found to cause differences in the statistics of peak wind speed in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between RSA and current sensors to determine if there are significant differences. Approximately 3 weeks of Legacy and RSA wind data from each range were used in the study, archived during May and June 2005. The ER data spanned the full diurnal cycle, while the WR data was confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on 5 different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The 10 towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The RSA sensors were collocated at the same vertical levels as the present sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with present sensors were compared. The 1-minute average wind speed/direction and the 1-second peak wind speed/direction were compared.

Short, D.↗

Relation of systemic and local muscle exercise capacity to skeletal muscle characteristics in men with congestive heart failure

OBJECTIVES. The present study was undertaken to further characterize changes in skeletal muscle morphology and histochemistry in congestive heart failure and to determine the relation of these changes to abnormalities of systemic and local muscle exercise capacity. BACKGROUND. Abnormalities of skeletal muscle appear to play a role in the limitation of exercise capacity in congestive heart failure, but information on the changes in muscle morphology and biochemistry and their relation to alterations in muscle function is limited. METHODS. Eighteen men with predominantly mild to moderate congestive heart failure (mean +/- SEM New York Heart Association functional class 2.6 +/- 0.2, ejection fraction 24 +/- 2%) and eight age- and gender-matched sedentary control subjects underwent measurements of peak systemic oxygen consumption (VO2) during cycle ergometry, resistance to fatigue of the quadriceps femoris muscle group and biopsy of the vastus lateralis muscle. RESULTS. Peak VO2 and resistance to fatigue were lower in the patients with heart failure than in control subjects (15.7 +/- 1.2 vs. 25.1 +/- 1.5 ml/min-kg and 63 +/- 2% vs. 85 +/- 3%, respectively, both p < 0.001). Patients had a lower proportion of slow twitch, type I fibers than did control subjects (36 +/- 3% vs. 46 +/- 5%, p = 0.048) and a higher proportion of fast twitch, type IIab fibers (18 +/- 3% vs. 7 +/- 2%, p = 0.004). Fiber cross-sectional area was smaller, and single-fiber succinate dehydrogenase activity, a mitochondrial oxidative marker, was lower in patients (both p < or = 0.034). Likewise, the ratio of average fast twitch to slow twitch fiber cross-sectional area was lower in patients (0.780 +/- 0.06 vs. 1.05 +/- 0.08, p = 0.019). Peak VO2 was strongly related to integrated succinate dehydrogenase activity in patients (r = 0.896, p = 0.001). Peak VO2, resistance to fatigue and strength also correlated significantly with several measures of fiber size, especially of fast twitch fibers, in patients. None of the skeletal muscle characteristics examined correlated with exercise capacity in control subjects. CONCLUSIONS. These results indicate that congestive heart failure is associated with changes in the characteristics of skeletal muscle and local as well as systemic exercise performance. There are fewer slow twitch fibers, smaller fast twitch fibers and lower succinate dehydrogenase activity. The latter finding suggests that mitochondrial content of muscle is reduced in heart failure and that impaired aerobic-oxidative capacity may play a role in the limitation of systemic exercise capacity.

Non-NASA Center↗