A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion↗

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume↗

Recommended Practice for Use of ExB Probes in Electric Propulsion Testing

An ExB probe is an electric propulsion plume diagnostic that has at its core a Wien filter. Ions entering the instrument experience perpendicular electric and magnetic fields and are filtered based on their velocity. While the ExB probe can be used to estimate the ion velocity distribution function, in the electric propulsion community, it is commonly used to measure species fractions. There are numerous probe designs, implementation and operation procedures, and data analysis approaches described and in use across the community. This paper provides recommendations and descriptions of best practices for design, implementation, and data analysis for the ExB probe, with a particular emphasis on Hall and ion thrusters. This work contributes to the broader community goal to standardize the use of diagnostics in electric propulsion testing.

ExB probe↗

Facility Effects on the Ion Characteristics of A 12.5-Kw Hall Thruster

During a laser-induced fluorescence test of a 12.5-kW magnetically-shielded Hall thruster, ion characteristics in the discharge channel and near the poles were measured as the background pressure and electrical configuration were varied. The acceleration zone of the thruster moved upstream by 2% and 10% of the channel length when the background pressure was raised to 1.8 times and 7 times the lowest achievable pressure, respectively. Examination of the characteristics of the ions near the pole covers suggested that as the background pressure decreased the pole covers may be experiencing more erosion. When operating at a discharge voltage of 300 V, the acceleration zone was observed to be at the same location for all electrical configurations. When operating at a discharge voltage of 600V, the acceleration zone was observed to move 3% of the channel length upstream when the thruster body was floated instead of tied to the cathode or grounded to the facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations. This observation combined with thruster body voltage measurements suggested that varying the electrical configuration only affected the thruster body sheath voltage and did not affect the plasma potential beyond the sheath.

Electric propulsion↗

LIF Testing of ETU-2 in VF-5

A visualization of the experimental setup for the Laser-Induced Fluorescence (LIF) diagnostic system applied to AEPS Engineering Test Unit 2 (ETU-2) in the Electric Propulsion and Power Laboratory's (EPPL) Vacuum Facility 5 (VF-5)

LIF↗

Evidence of Counter-Streaming Ions near the Inner Pole of the HERMeS Hall Thruster

NASA is continuing the development of a 12.5-kW Hall thruster system to support a phased exploration concept to expand human presence to cis-lunar space and eventually to Mars. The development team is transitioning knowledge gained from the testing of the government-built Technology Development Unit (TDU) to the contractor-built Engineering Test Unit (ETU). A new laser-induced fluorescence diagnostic was developed to obtain data for validating the Hall thruster models and for comparing the behavior of the ETU and TDU. Analysis of TDU LIF data obtained during initial deployment of the diagnostics revealed evidence of two streams of ions moving in opposite directions near the inner front pole. These two streams of ions were found to intersect the downstream surface of the front pole at large oblique angles. This data points to a possible explanation for why the erosion rate of polished pole covers were observed to decrease over the course of several hundred hours of thruster operation.

Wensheng Huang↗

HERMeS Thruster Magnetic Field Topology Optimization Study: Plasma Plume Results

NASA’s Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. The magnetic optimization study aims to explore and investigate alternate magnetic field topologies. Four candidate magnetic field topologies that reduce the effectiveness of the shielding along the discharge channel walls with the intent to also reduce the erosion rates along the front pole covers were designed. Three of the four candidate magnetic field topologies (B1, B2, and B4) have been manufactured and were subjected to an extensive test campaign that included laser induced fluorescence (LIF), performance, stability, wear, and plume characterization. In Phase I, LIF measurements along the discharge chamber centerline found that upstream retraction of the thruster’s peak magnetic field does result in an upstream shift of the acceleration zone, but the magnitude of the shift does not correspond one-to-one to the shift in the location of the peak radial magnetic field magnitude. Phase II test segment results found that at a normalized thruster magnetic field setting of 1, the thruster performance and discharge current oscillations were very similar for configurations B0-B2. Also in Phase II abbreviated wear tests found that average inner front pole cover erosion rates for configuration B1 were approximately 65% of those at B0, and the average erosion rates for configuration B2 were approximately 35% of those at B0. This paper reports on the detailed plasma plume mapping results for configurations B0-B4. Faraday probe results indicate that, at 600 V operation, the plume divergence increased slightly for the B4 configuration when compared to B0-B2. Wien filter spectrometer results found that at 600 V, lower multiply-charged species fractions were attained as the thruster transitioned from configurations B0 to B4. Finally, retarding potential analyzer results found that at 600 V operation and at angles above 60,˚ significantly lower high-energy ion content was found for configurations B2 and B4 when compared to B0 and B1.

Electric propulsion,.Hall thruster, laser diagnost↗

Wear Test of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first wear test of the 12.5 kW Advanced Electric Propulsion System Engineering Test Unit 2 (AEPS ETU-2) thruster produced by Aerojet Rocketdyne. The ETU-2 Wear Test accumulated approximately 730 hours of operation split between the nominal 600 V/12.5 kW condition and the 300 V/6.25 kW condition previously identified as the worst-case erosion condition.

Jason D. Frieman↗

Characterization Test of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the detailed characterization testof the 12.5 kW Advanced Electric Propulsion System Engineering Test Unit 2 (AEPS ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had two major goals: to assessthe risk of design compliance with thruster requirements and providea comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding Technology Demonstration Units (HERMeS TDUs) from which the AEPS ETU design was derived.

AEPS↗

Effects of Background Pressure and Electrical Configuration on the Velocity Field of the HERMeS Hall Thruster

A Laser-Induced Fluorescence test was performed during risk reduction testing on the HERMeS Hall thruster. This article focuses on the portion of the test to study trends in the ion acceleration characteristics with varying anode mass flow rate, background pressure, and electrical configuration. The acceleration zone of the HERMeS Hall thruster was observed to move upstream as the anode mass flow rate decreased and upstream as the background pressure increased. Examination of the characteristics of the ions near the pole covers suggested the possibility that thruster was no longer magnetically shielded at the extreme conditions of very low anode mass flow rate and high background pressure. The acceleration zone was also observed to move slightly upstream when the thruster body was floated as opposed to cathode-tied and did not move appreciably when the thruster body was grounded to the vacuum facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations.

Electric Propulsion↗

Performance of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the performance test campaign of the 12.5 kW Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had three major goals: to assess design compliance with thruster requirements, provide a comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Units (TDUs) from which the AEPS ETU design was derived, and support AEPS application on the Power and Propulsion Element (PPE). Assessments of ETU-2 performance were conducted at discharge powers of 2.6 to 13.1 kW, which encompasses the original AEPS throttle conditions as well as those most relevant for AEPS application on PPE. The results from the test campaign indicate that ETU-2 performance meets or exceeds all AEPS thruster performance requirements and matches the values and trends previously measured with the HERMeS TDUs. In addition, similar to the HERMeS TDUs, ETU-2 performance showed minimal variation over approximately 1636 h of operating time due to the incorporation of magnetic shielding. Taken together, these results show that the AEPS design is successfully replicating the performance of the HERMeS TDUs to within the empirical uncertainty and meeting its performance requirements as the design progresses to its Critical Design Review.

HERMeS↗

Performance of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the performance test campaign of the 12.5 kW Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had three major goals: to assess design compliance with thruster requirements, provide a comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Units (TDUs) from which the AEPS ETU design was derived, and support AEPS application on the Power and Propulsion Element (PPE). Assessments of ETU-2 performance were conducted at discharge powers of 2.6 to 13.1 kW, which encompasses the original AEPS throttle conditions as well as those most relevant for AEPS application on PPE. The results from the test campaign indicate that ETU-2 performance meets or exceeds all AEPS thruster performance requirements and matches the values and trends previously measured with the HERMeS TDUs. In addition, similar to the HERMeS TDUs, ETU-2 performance showed minimal variation over approximately 1636 h of operating time due to the incorporation of magnetic shielding. Taken together, these results show that the AEPS design is successfully replicating the performance of the HERMeS TDUs to within the empirical uncertainty and meeting its performance requirements as the design progresses to its Critical Design Review.

Jason D Frieman↗