Search NASA⌕ Search

Engineering topics

Werner, C.

Publications and source records attributed to Werner, C..

Modeling Microgravity Induced Fluid Redistribution Autoregulatory and Hydrostatic Enhancements

Space flight induces a marked cephalad (headward) redistribution of blood and interstitial fluid potentially resulting in a loss of venous tone and reduction in heart muscle efficiency upon introduction into the microgravity environment. Using various types of computational models, we are investigating how this fluid redistribution may induce intracranial pressure changes, relevant to reported reductions in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome. Methods: We utilize a lumped parameter cardiovascular system (CVS) model, augmented by compartments comprising the cerebral spinal fluid (CSF) space, as the primary tool to describe how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. Models of ocular fluid pressures and biomechanics then accept the output of the above model as boundary condition input to allow more detailed, local analysis (see IWS Abstract by Ethier et al.). Recently, we enhanced the capabilities our previously reported CVS model through the implementation of robust autoregulatory mechanisms and a more fundamental approach to the implementation of hydrostatic mechanisms. Modifying the approach of Blanco et al., we implemented auto-regulation in a quasi-static manner, as an averaged effect across the span of one heartbeat. This approach reduced the higher frequency perturbations from the regulatory mechanism and was intended to allow longer simulation times (days) than models that implement within-beat regulatory mechanisms (minutes). A more fundamental approach to hydrostatics was implemented by a quasi-1D approach, in which compartment descriptions include compartment length, orientation and relative position, allowed for modeling of body orientation, relative body positioning and, in the future, alternative gravity environments. At this time the inclusion of hydrostatic mechanisms supplies additional capabilities to train and validate the CVS model with terrestrial data. Results and Conclusions: With the implementation of auto-regulation and hydrostatic modeling capabilities, the model performs as expected in the maintaining the CA (Central Artery) compartment pressure when simulating orientations ranging from supine to standing. The model appears to generally overpredict heart rate and thus cardiac output, possibly indicating sensitivity to the nominal heart rate, which is used as an initial set point of the regulation mechanisms. Despite this sensitivity, the model performs consistently for many hours of simulation time, indicating the success of our quasi-static implementation approach.

biomechanics↗

Influence of Population Variation of Physiological Parameters in Computational Models of Space Physiology

The earliest manifestations of Visual Impairment and Intracranial Pressure (VIIP) syndrome become evident after months of spaceflight and include a variety of ophthalmic changes, including posterior globe flattening and distension of the optic nerve sheath. Prevailing evidence links the occurrence of VIIP to the cephalic fluid shift induced by microgravity and the subsequent pressure changes around the optic nerve and eye. Deducing the etiology of VIIP is challenging due to the wide range of physiological parameters that may be influenced by spaceflight and are required to address a realistic spectrum of physiological responses. Here, we report on the application of an efficient approach to interrogating physiological parameter space through computational modeling. Specifically, we assess the influence of uncertainty in input parameters for two models of VIIP syndrome: a lumped-parameter model (LPM) of the cardiovascular and central nervous systems, and a finite-element model (FEM) of the posterior eye, optic nerve head (ONH) and optic nerve sheath. Methods: To investigate the parameter space in each model, we employed Latin hypercube sampling partial rank correlation coefficient (LHSPRCC) strategies. LHS techniques outperform Monte Carlo approaches by enforcing efficient sampling across the entire range of all parameters. The PRCC method estimates the sensitivity of model outputs to these parameters while adjusting for the linear effects of all other inputs. The LPM analysis addressed uncertainties in 42 physiological parameters, such as initial compartmental volume and nominal compartment percentage of total cardiac output in the supine state, while the FEM evaluated the effects on biomechanical strain from uncertainties in 23 material and pressure parameters for the ocular anatomy. Results and Conclusion: The LPM analysis identified several key factors including high sensitivity to the initial fluid distribution. The FEM study found that intraocular pressure and intracranial pressure had dominant impact on the peak strains in the ONH and retro-laminar optic nerve, respectively; optic nerve and lamina cribrosa stiffness were also important. This investigation illustrates the ability of LHSPRCC to identify the most influential physiological parameters, which must therefore be well-characterized to produce the most accurate numerical results.

biomechanics↗

Microgravity-Induced Physiological Fluid Redistribution: Computational Analysis to Assess Influence of Physiological Parameters

Space flight impacts human physiology in many ways, the most immediate being the marked cephalad (headward) shift of fluid upon introduction into the microgravity environment. This physiological response to microgravity points to the redistribution of blood and interstitial fluid as a major factor in the loss of venous tone and reduction in heart muscle efficiency which impact astronaut performance. In addition, researchers have hypothesized that a reduction in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome, is associated with this redistribution of fluid. VIIP arises within several months of beginning space flight and includes a variety of ophthalmic changes including posterior globe flattening, distension of the optic nerve sheath, and kinking of the optic nerve. We utilize a suite of lumped parameter models to simulate microgravity-induced fluid redistribution in the cardiovascular, central nervous and ocular systems to provide initial and boundary data to a 3D finite element simulation of ocular biomechanics in VIIP. Specifically, the lumped parameter cardiovascular model acts as the primary means of establishing how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. The cardiovascular model consists of 16 compartments, including three cerebrospinal fluid (CSF) compartments, three cranial blood compartments, and 10 thoracic and lower limb blood compartments. To assess the models capability to address variations in physiological parameters, we completed a formal uncertainty and sensitivity analysis that evaluated the relative importance of 42 input parameters required in the model on relative compartment flows and compartment pressures. Utilizing the model in a pulsatile flow configuration, the sensitivity analysis identified the ten parameters that most influenced each compartment pressure. Generally, each compartment responded appropriately to parameter variations associated with itself and adjacent compartments. However, several unexpected interactions between components, such as between the choroid plexus and the lower capillaries, were found, and are due to simplifications in the formulation of the model. The analysis illustrates that highly influential parameters and those that have unique influences within the model formulation must be tightly controlled for successful model application.

gravitational physiology↗

ERS-1 Bistatic Radar Images

Explore the source record for details and available documents.

ERS-1 satellite signals Oklahoma City bistatic ima↗

Results of the 1988 NASA/JPL airborne SAR calibration campaign

During the spring of 1988, the NASA/JPL multifrequency, multipolarization SAR (synthetic aperture radar) flew in series of calibration experiments over the Goldstone dry lake bed. An array of calibration devices was deployed, including dihedral and trihedral corner reflectors, polarimetric active radar calibrators, passive receivers, and CW (continuous wave) tone generators. The aim of the campaign was to calibrate both amplitude and phase of the resulting SAR images, over long and short time scales. The results of the analysis of the calibration data collected in the spring of 1988 are presented. Trihedral corner reflector signatures and certain image background measures are used to externally calibrate relative amplitude and phase between polarizations at a given frequency, and to calibrate across frequencies. Assessments are made of the calibration accuracy as a function of image frame position for each frequency, and the stability of the radar calibration over long and short time-scales.

Freeman, A.↗

Calibration of multipolarisation imaging radar

An experiment was designed to calibrate airborne imaging radar (AIR) images, in terms of relative and absolute backscatter, and relative phase between polarization channels. The calibration uses measurements made within the radar system itself (internal calibration) and using ground-based corner reflectors and transponders (external calibration). The techniques developed for the AIR calibration campaign will form the basis of the calibration approach for SIR-C.

Freeman, A.↗

MIE Lidar proposed for the German Space Shuttle Mission D2

Firm plans for a second German Spacelab mission (D2-mission), originally scheduled for late 1988 is basically a zero-g mission, but will also include earth observation experiments. On board the D2-facility will allow performance of a number of different measurements with the goal to obtain performance data (cloud top heights, height of the planetary boundary layer, optical thickness, and cloud base height of thin and medium thick clouds, ice/water phase discriminatin for clouds, tropopause height, tropaspheric height, tropospheric aerosols, and stratospheric aerosols.

Renger, W.↗

CV-990 L-band SAR: A calibration experiment

Calibrated image data is required by most users of synthetic aperture radar (SAR) data particularly those attempting to classify targets based upon their radar backscatter signature as a function of frequency polarization or incidence angle. In this experiment, the backscatter derived by calibrating the NASA/JPL CV-990 L-band SAR, and the backscatter reported from a pass of the NASA/JSC C-130 scatterometer as the two instruments flew over the same site at different times are compared.

Held, D. N.↗

The absolute amplitude calibration of the SEASAT synthetic aperture radar - An intercomparison with other L-band radar systems

The absolute amplitude calibration of the spaceborne Seasat SAR data set is presented based on previous relative calibration studies. A scale factor making it possible to express the perceived radar brightness of a scene in units of sigma-zero is established. The system components are analyzed for error contribution, and the calibration techniques are introduced for each stage. These include: A/D converter saturation tests; prevention of clipping in the processing step; and converting the digital image into the units of received power. Experimental verification was performed by screening and processing the data of the lava flow surrounding the Pisgah Crater in Southern California, for which previous C-130 airborne scatterometer data were available. The average backscatter difference between the two data sets is estimated to be 2 dB in the brighter, and 4 dB in the dimmer regions. For the SAR a calculated uncertainty of 3 dB is expected.

Held, D.↗