Search NASA⌕ Search

Engineering topics

West, David L

Publications and source records attributed to West, David L.

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

Compact, DC-electrical biased sulfur dioxide sensing elements for use at high temperatures

Fabrication and operation of sensing elements for the detection of sulfur dioxide (SO_2) at high temperature (800 900 ^oC) is reported. The sensing elements consisted of three (two oxide and one Pt) electrodes on yttria-stabilized zirconia substrates. To operate the elements, a DC current (typically about 0.1 mA) is driven between two of the electrodes and the voltage between one of these electrodes and the third electrode is used as the sensing signal. These sensing elements respond very strongly to SO_2, for example 2 ppm_V of SO_2 in a background of 7 vol% O_2, balance N_2 was found to produce a >10% change in the sensing signal, which could be easily detected. Sensing elements fabricated to be nominally identical were shown to yield qualitatively identical sensing behavior, and temperature, oxygen content, and flow were all found to strongly impact sensing performance. The impact of interferents, such as NO_x and CO, was evaluated and found to be relatively small in comparison to the SO_2 response. The sensing response, over a 1 month period, was very stable, with the ratio of the average change in sensing signal over one day to the average sensing signal magnitude being about 0.1%.

36 MATERIALS SCIENCE↗

Scaling and Optimization of Magnetic Refrigeration for Commercial Building HVAC Systems Greater than 175 kW in Capacity

Heating, ventilation, air-conditioning and refrigeration (HVACR) account for approximately one- third of building energy consumption. Magnetic refrigeration presents an opportunity for significant energy savings and emissions reduction for serving the building heating, cooling, and refrigeration loads. In this paper, we have examined the magnet and MCE material requirements for scaling magnetic refrigeration systems for commercial building cooling applications. Scaling relationships governing the resources required for magnetic refrigeration systems have been developed. As system refrigeration capacity increases, the use of superconducting magnet systems becomes more applicable, and a comparison is presented of system requirements for permanent and superconducting (SC) magnetization systems. Included in this analysis is an investigation of the ability of superconducting magnet based systems to overcome the parasitic power penalty of the cryocooler used to keep SC windings at cryogenic temperatures. Scaling relationships were used to develop the initial specification for a SC magnet-based active magnetic regeneration (AMR) system. An optimized superconducting magnet was designed to support this system. In this analysis, we show that the SC magnet system consisting of two 0.38 m3 regenerators is capable of producing 285 kW of cooling power with a T of 28 K. A system COP of 4.02 including cryocooler and fan losses which illustrates that an SC magnet-based system can operate with efficiency comparable to traditional systems and deliver large cooling powers of 285.4 kW (81.2 Tons).

magnetic refrigeration↗

THERMAL IMAGING OF ACTIVE MAGNETIC REGERNERATOR MCE MATERIALS DURING OPERATION

An active magnetic regenerator (AMR) prototype was constructed that incorporates a Gd sheet into the regenerator wall to enable visualization of the system s thermal transients. In this experiment, the thermal conditions inside the AMR are observed under a variety of operating conditions. An infrared (IR) camera is employed to visualize the thermal transients within the AMR. The IR camera is used to visually and quantitatively evaluate the temperature difference and thus giving means to calculate the performance of the system under the various operating conditions. Thermal imaging results are presented for two differing experimental test runs. Real time imaging of the thermal state of the AMR has been conducted while operating the system over a range of conditions. A 1 Tesla twin-coil electromagnet (situated on a C frame base) is used for this experiment such that all components are stationary during testing. A modular, linear reciprocating system has been realized in which the effects of regenerator porosity and utilization factor can be investigated. To evaluate the performance variation in porosity and utilization factor the AMR housing was constructed such that the plate spacing of the Gd sheets may be varied. Each Gd sheet has dimensions of 38 mm wide and 66 mm long with a thickness of 1 mm and the regenerator can hold a maximum of 29 plates with a spacing of 0.25 mm. Quantitative and thermal imaging results are presented for several regenerator configurations.

Shassere, Benjamin↗

Supply Chain Based Solution to Prevent Fuel Tax Evasion: Proof of Concept Final Report

The goal of this research was to provide a proof-of-concept (POC) system for preventing non-taxable (non-highway diesel use) or low-taxable (jet fuel) petrochemical products from being blended with taxable fuel products and preventing taxable fuel products from cross-jurisdiction evasion. The research worked to fill the need to validate the legitimacy of individual loads, offloads, and movements by integrating and validating, on a near-real-time basis, information from global positioning system (GPS), valve sensors, level sensors, and fuel-marker sensors.

02 PETROLEUM↗

Device and method for detecting sulfur dioxide at high temperatures

The present invention relates to a method for selectively detecting and/or measuring gaseous SO.sub.2 at a temperature of at least 500.degree. C., the method involving: (i) providing a SO.sub.2-detecting device including an oxygen ion-conducting substrate having on its surface at least three electrodes comprising a first, second, and third electrode; (ii) driving a starting current of specified magnitude and temporal variation between the first and second electrodes; (iii) contacting the SO.sub.2-detecting device with the SO.sub.2-containing sample while maintaining the magnitude and any temporal variation of the starting current, wherein said SO.sub.2-containing sample causes a change in the electrical conductance of said device; and (iv) detecting the change in electrical conductance of the device based on measuring an electrical property related to or indicative of the conductance of the device between the first and third electrodes, or between the second and third electrodes, and detecting SO.sub.2 in the SO.sub.2-containing sample based on the measured change in electrical conductance.

47 OTHER INSTRUMENTATION↗

NO.sub.x sensing devices having conductive oxide electrodes

A NO.sub.x sensing device includes at least one pair of spaced electrodes, at least one of which is made of a conductive oxide, and an oxygen-ion conducting material in bridging electrical communication with the electrodes.

Montgomery, Frederick C↗

A technique for monitoring SO2 in combustion exhausts: Use of a non-Nernstian sensing element in combination with an upstream catalytic filter

Detection of sulfur dioxide (SO2) at high temperature (600 750 oC) in the presence of some interferents found in typical combustion exhausts (oxides of nitrogen (NO2 and NO, "NOx"), CO2, CO, and hydrocarbon (C3H6)) is described. The detection scheme involves use of a catalytic filter in front of a non-Nernstian sensing element. The catalytic filter was a Ni:Cr powder bed operating at 850 oC and the sensing elements were pairs of platinum (Pt) and oxide (Ba-promoted copper chromite ((Ba,Cu)xCryOz) and Sr-modified lanthanum ferrite (LSF)) electrodes on yttria-stabilized zirconia. The Ni:Cr powder bed was capable of reducing the sensing element response to NOx, CO, and C3H6, but the presence of NOx (100 ppm by volume) still interfered with the SO2 response of the Pt-(Ba,Cu)xCryOz sensing element at 600 oC, causing approximately a 7 mV (20%) reduction in the response to 120 ppm SO2 and a response equivalent to about 20 ppm SO2 in the in the absence of SO2. The Pt-LSF sensing element, operated at 750 oC, did not suffer from this NOx interference but at the cost of a reduced SO2 response magnitude (120 ppm SO2 yielded ~10 mV, in contrast to ~30 mV for the Pt-(Ba,Cu)xCryOz sensing element). The powder bed and Pt-LSF sensing element were operated continuously over approximately 350 hours, and the response to SO2 drifted downward by about 7%, with most of this change occurring during the initial 100 hours of operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress in Creating Stabilized Gas Layers in Flowing Liquid Mercury

The Spallation Neutron Source (SNS) facility in Oak Ridge, Tennessee uses a liquid mercury target that is bombarded with protons to produce a pulsed neutron beam for materials research and development. In order to mitigate expected cavitation damage erosion (CDE) of the containment vessel, a two-phase flow arrangement of the target has been proposed and was earlier proven to be effective in significantly reducing CDE in non-prototypical target bodies. This arrangement involves covering the beam "window", through which the high-energy proton beam passes, with a protective layer of gas. The difficulty lies in establishing a stable gas/liquid interface that is oriented vertically with the window and holds up to the strong buoyancy force and the turbulent mercury flow field. Three approaches to establishing the gas wall have been investigated in isothermal mercury/gas testing on a prototypical geometry and flow: (1) free gas layer approach, (2) porous wall approach, and (3) surface-modified approach. The latter two of these approaches show success in that a stabilized gas layer is produced. Both of these successful approaches capitalize on the high surface energy of liquid mercury by increasing the surface area of the solid wall, thus increasing gas hold up at the wall. In this paper, a summary of these experiments and findings is presented as well as a description of the path forward toward incorporating the stabilized gas layer approach into a feasible gas/mercury SNS target design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DETECTION OF SO2 AT HIGH TEMPERATURE WITH ELECTRICALLY BIASED, SOLID-ELECTROLYTE SENSING ELEMENTS

Design and operation of sensing elements for the detection of sulfur dioxide (SO2) at high temperature (800 900 oC) is described. The sensing elements consisted of three (two oxide and one Pt) electrodes on yttria-stabilized zirconia substrates. To operate the elements, a constant current (usually on the order of 0.1 mA) was driven between two of the electrodes and the voltage between one of these electrodes and the third electrode was monitored and used as the sensing signal. In one example, 31 ppm SO2 caused an approximately 40% change in the element output, and 2 ppm of SO2 could be easily detected. The cross-sensitivity to several interferents such as NOx was evaluated and found to be relatively small in comparison to the SO2 response.

01 COAL, LIGNITE, AND PEAT↗