Search NASA⌕ Search

Engineering topics

West, M

Publications and source records attributed to West, M.

SU-F-J-116: Clinical Experience-Based Verification and Improvement of a 4DCT Program

Purpose: To demonstrate the role of continuous improvement fulfilled by the Medical Physicist in clinical 4DCT and CBCT scanning. Methods: Lung (SABR and Standard) patients’ 4D respiratory motion and image data were reviewed over a 3, 6 and 12 month period following commissioning testing. By identifying trends of clinically relevant parameters and respiratory motions, variables were tested with a programmable motion phantom and assessed. Patient traces were imported to a motion phantom and 4DCT and CBCT imaging were performed. Cos6 surrogate and sup-inf motion was also programmed into the phantom to simulate the long exhale of patients for image contrast tests. Results: Patient surrogate motion amplitudes were 9.9+5.2mm (3–35) at 18+6bpm (6–30). Expiration/Inspiration time ratios of 1.4+0.5second (0.6–2.9) showed image contrast effects evident in the AveCT and 3DCBCT images. Small differences were found for patients with multiple 4DCT data sets. Patient motion assessments were simulated and verified with the phantom within 2mm. Initial image reviews to check for reconstructed artefacts and data loss identified a small number of patients with irregularities in the automatic placement of inspiration and expiration points. Conclusion: The Physicist’s involvement in the continuous improvements of a clinically commissioned technique, processes and workflows continues beyond the commissioning stage of a project. Our experience with our clinical 4DCT program shows that Physics presence is required at the clinical 4DCT scan to assist with technical aspects of the scan and also for clinical image quality assessment prior to voluming. The results of this work enabled the sharing of information from the Medical Physics group with the Radiation Oncologists and Radiation Therapists. This results in an improved awareness of clinical patient respiration variables and how they may affect 4D simulation images and also may also affect the treatment verification images.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-08: External and Internal Motion Assessments with Amplitude and Time Based Reconstruction and AveCT

Purpose: To investigate the effects of external surrogate and tumour motion by observing the reconstructed phases and AveCT in an Amplitude and Time based 4DCT. Methods: Based on patient motion studies, Cos6 and sinusoidal motions were simulated as external surrogate and tumour motions in a motion phantom. The diaphragm and tumour motions may or may not display the same waveform therefore the same and different waveforms were programmed into the phantom, scanned and reconstructed based on Amplitude and Time. The AveCT and phases were investigated with these different scenarios. The AveCT phantom images were also compared with CBCT phantom images programmed with the same motions. Results: For the same surrogate and tumour sin motions, the phases (Amplitude and Time) and AveCT indicated similar motions based on the position of the BB at the slice and displayed contrast values respectively. For cos6 motions, due to the varied time the tumour spends at each position, the Amplitude and Time based phases differed. The AveCT images represented the actual tumour motions and the Time and Amplitude based phases were represented by the surrogate with varied times. Conclusion: Different external surrogate and tumour motions may result in different displayed image motions when observing the AveCT and reconstructed phases. During the 4DCT, the surrogate motion is readily available for observation of the amplitude and time of the diaphragm position. Following image reconstruction, the user may need to observe the AveCT in addition to the reconstructed phases to comprehend the time weightings of the tumour motion during the scan. This may also apply to 3D CBCT images where the displayed tumour position in the images is influenced by the long duration of the CBCT. Knowledge of the tumour motion represented by the greyscale of the AveCT may also assist in CBCT treatment beam verification matching.

60 APPLIED LIFE SCIENCES↗

Weighted Flow Algorithms (WFA) for stochastic particle coagulation

Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.

97 MATHEMATICS AND COMPUTING↗

Technical Review Report for the Justification for 9975 Gram Based Content Envelopes, C.10 and C.11

The Department of Energy (DOE) desires to ship Model 9975-85 and Model 9975-96 Packages loaded with Pu/U metal and Pu/U oxide materials as identified in new Content Envelopes C.10 and C.11. The new Content Envelopes C.10 and C.11 consist of radioisotopes and impurities that are similar to the existing C.3, Pu/U metal, and C.4, Pu/U oxide, Content Envelopes but that list the radioisotopes as gram values in lieu of the existing weight percent of radioactive material mass values listed for the C.3 and C.4 Content Envelopes. Authorization for shipment requires acceptance of this report by the DOE-Headquarters (HQ) Certifying Official (EM-10/EM-2) as an Addendum to WSRC-SA-2002-00008, Revision 0, S-SARA-G-00001, Addendum 1, Revision 0, and S-SARA-G-00002 Addendum 2, Revision 1, of the Model 9975-85 Package Safety Analysis Report for Packaging (SARP). This Addendum also applies to S-SARP-G-00003, Revision 0, of the Model 9975-96 Package SARP. These documents are collectively referred to as the existing Model 9975 Package SARP. The safety basis described addresses specific supplements to the currently approved safety basis. Justification is made for shipping the new Content Envelopes C.10 and C.11 under this Addendum. Following acceptance of this Addendum by EM-10/EM-2 and subsequent revision to the current Certificates of Compliance (CoCs), the new contents will be authorized for shipment in the Model 9975 Package. The new Content Envelopes will be incorporated into the next revision to the Model 9975-85 and Model 9975-96 Package SARPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Review Report for the Model 9975-96 Package Safety Analysis Report for Packaging (S-SARP-G-00003, Revision 0, January 2008)

This Technical Review Report (TRR) documents the review, performed by the Lawrence Livermore National Laboratory (LLNL) Staff, at the request of the U.S. Department of Energy (DOE), on the Safety Analysis Report for Packaging, Model 9975, Revision 0, dated January 2008 (S-SARP-G-00003, the SARP). The review includes an evaluation of the SARP, with respect to the requirements specified in 10 CFR 71, and in International Atomic Energy Agency (IAEA) Safety Standards Series No. TS-R-1. The Model 9975-96 Package is a 35-gallon drum package design that has evolved from a family of packages designed by DOE contractors at the Savannah River Site. Earlier package designs, i.e., the Model 9965, the Model 9966, the Model 9967, and the Model 9968 Packagings, were originally designed and certified in the early 1980s. In the 1990s, updated package designs that incorporated design features consistent with the then newer safety requirements were proposed. The updated package designs at the time were the Model 9972, the Model 9973, the Model 9974, and the Model 9975 Packagings, respectively. The Model 9975 Package was certified by the Packaging Certification Program, under the Office of Safety Management and Operations. The safety analysis of the Model 9975-85 Packaging is documented in the Safety Analysis Report for Packaging, Model 9975, B(M)F-85, Revision 0, dated December 2003. The Model 9975-85 Package is certified by DOE Certificate of Compliance (CoC) package identification number, USA/9975/B(M)F-85, for the transportation of Type B quantities of uranium metal/oxide, {sup 238}Pu heat sources, plutonium/uranium metals, plutonium/uranium oxides, plutonium composites, plutonium/tantalum composites, {sup 238}Pu oxide/beryllium metal.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Review Report for the Application for Contents Amendment for Shipping Isentropic Compression Experiment (ICE) Apparatus in 9977 Packaging

This report documents the review of Application for Contents Amendment for Shipping Isentropic Compression Experiment (ICE) Apparatus in 9977 Packaging, prepared by Savannah River Packaging Technology (SRPT) of Savannah River National Laboratory (SRNL) of Savannah River Nuclear Solutions, LLC, -- the Submittal -- at the request of the Department of Energy's (DOE) National Nuclear Security Agency's (NNSA) Albuquerque Facility Operations Division, for the shipment of the ICE apparatus from Los Alamos National Laboratory (LANL), to Sandia National Laboratory (SNL). The ICE apparatus consists of a stainless steel assembly containing about 8 grams of {sup 239}Pu or its dose equivalent as noted in Table 1, Comparison of 9977 Content C.1 and the ICE Radioactive Contents, of the Submittal. The ICE target is mounted on the transport container assembly base. A Viton{sup R} O-ring seals the transport container base to the transport container body. Another Viton{sup R} O-ring seals the transport container handle to the transport container body. The ICE apparatus weighs less than 30 pounds and has less than 0.6 watts decay heat rate. For the Model 9977 Package, the maximum payload weight is 100 pounds and the maximum decay heat rate is 19 watts. Thus, the maximum payload weight and the maximum decay heat rate for the Model 9977 Package easily bound those for the ICE apparatus. This Addendum supplements the Safety Analysis Report for Packaging (SARP), Revision 2, for the Model 9977 Package and Addendum 1, Revision 2, to Revision 2 of the Model 9977 Package SARP. The ICE apparatus is considered as part of Content Envelope C.6, Samples and Sources, under the submittal for the Model 9978 Package SARP currently under review. The Staff at Lawrence Livermore National Laboratory (LLNL) recommends that the Submittal be approved by the DOE-Headquarters Certifying Official (EM-60), and incorporated into a subsequent revision to the current Certificate of Compliance (CoC), to the Model 9977-96 Packaging.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Review Report for the Model 9978-96 Package Safety Analysis Report for Packaging (S-SARP-G-00002, Revision 1, March 2009)

This Technical Review Report (TRR) documents the review, performed by Lawrence Livermore National Laboratory (LLNL) Staff, at the request of the Department of Energy (DOE), on the 'Safety Analysis Report for Packaging (SARP), Model 9978 B(M)F-96', Revision 1, March 2009 (S-SARP-G-00002). The Model 9978 Package complies with 10 CFR 71, and with 'Regulations for the Safe Transport of Radioactive Material-1996 Edition (As Amended, 2000)-Safety Requirements', International Atomic Energy Agency (IAEA) Safety Standards Series No. TS-R-1. The Model 9978 Packaging is designed, analyzed, fabricated, and tested in accordance with Section III of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME B&PVC). The review presented in this TRR was performed using the methods outlined in Revision 3 of the DOE's 'Packaging Review Guide (PRG) for Reviewing Safety Analysis Reports for Packages'. The format of the SARP follows that specified in Revision 2 of the Nuclear Regulatory Commission's Regulatory Guide 7.9, i.e., 'Standard Format and Content of Part 71 Applications for Approval of Packages for Radioactive Material'. Although the two documents are similar in their content, they are not identical. Formatting differences have been noted in this TRR, where appropriate. The Model 9978 Packaging is a single containment package, using a 5-inch containment vessel (5CV). It uses a nominal 35-gallon drum package design. In comparison, the Model 9977 Packaging uses a 6-inch containment vessel (6CV). The Model 9977 and Model 9978 Packagings were developed concurrently, and they were referred to as the General Purpose Fissile Material Package, Version 1 (GPFP). Both packagings use General Plastics FR-3716 polyurethane foam as insulation and as impact limiters. The 5CV is used as the Primary Containment Vessel (PCV) in the Model 9975-96 Packaging. The Model 9975-96 Packaging also has the 6CV as its Secondary Containment Vessel (SCV). In comparison, the Model 9975 Packagings use Celotex{trademark} for insulation and as impact limiters. To provide a historical perspective, it is noted that the Model 9975-96 Packaging is a 35-gallon drum package design that has evolved from a family of packages designed by DOE contractors at the Savannah River Site. Earlier package designs, i.e., the Model 9965, the Model 9966, the Model 9967, and the Model 9968 Packagings, were originally designed and certified in the early 1980s. In the 1990s, updated package designs that incorporated design features consistent with the then-newer safety requirements were proposed. The updated package designs at the time were the Model 9972, the Model 9973, the Model 9974, and the Model 9975 Packagings, respectively. The Model 9975 Package was certified by the Packaging Certification Program, under the Office of Safety Management and Operations. The Model 9978 Package has six Content Envelopes: C.1 ({sup 238}Pu Heat Sources), C.2 ( Pu/U Metals), C.3 (Pu/U Oxides, Reserved), C.4 (U Metal or Alloy), C.5 (U Compounds), and C.6 (Samples and Sources). Per 10 CFR 71.59 (Code of Federal Regulations), the value of N is 50 for the Model 9978 Package leading to a Criticality Safety Index (CSI) of 1.0. The Transport Index (TI), based on dose rate, is calculated to be a maximum of 4.1.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Review Report for the Justification for 233U Content Envelope Safety Analysis Report for Packaging Model 9975-85, Addendum 2

This report documents the review of Addendum 2, Justification for {sup 233}U Content Envelope, Safety Analysis Report for Packaging, prepared by Savannah River Packaging Technology (SRPT) of Savannah River National Laboratory (SRNL),--the Submittal--at the request of the Department of Energy's (DOE) National Nuclear Security Agency's (NNSA) Albuquerque Operations Office, for the shipment of 233U-bearing material from Los Alamos National Laboratory (LANL), in support of the Technical Area 18 (TA-18) Materials Relocation Program. This Addendum supplements the Safety Analysis Report for Packaging (SARP), Revision 0, and Addendum 1 to Revision 0 of the 9975 SARP (called Revision 0 of the 9975 SARP in this Addendum). The {sup 233}U-bearing items are currently stored at TA-18, awaiting shipment in the Model 9975-85 Package as a new Content Envelope, C.9. Following acceptance of this Addendum by the DOE-Headquarters Certifying Official (EM-60), and subsequent revision to the current Certificate of Compliance (CoC), the new contents will be authorized for shipment in the Model 9975-85 Package. The new Content Configuration, C.9, along with the optional Shielded-Pig Convenience Container Configuration, will be incorporated into the next revision of the Model 9975-85 Package SARP. In addition to the {sup 233}U-bearing items stored at TA-18, kilogram quantities of {sup 233}U-bearing materials are stored at Oak Ridge National Laboratory (ORNL). About one quarter of the items is Highly Enriched Uranium (HEU) as U{sub 3}O{sub 8} with {sup 233}U and {sup 232}U. Highly Enriched Uranium implies a {sup 236}U enrichment of >93%. The remaining material located at ORNL is pure {sup 233}U (>90%) with varying amounts of {sup 232}U. The form of the material is U{sub 3}O{sub 8}, UO{sub 3}, UO{sub 2}, and U metal. Additional DOE Sites may also have {sup 233}U-bearing materials for shipment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technical Review Report for the Mound 1KW Package Safety Analysis Report for Packaging Waiver for the Use of Modified Primary Containment Vessel (PCV)

This Technical Review Report (TRR) documents the review, performed by the Lawrence Livermore National Laboratory (LLNL) staff, at the request of the U.S. Department of Energy (DOE), on the Waiver for the Use of Modified Primary Containment Vessels (PCV). The waiver is to be used to support a limited number of shipments of fuel for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) Project in support of the National Aeronautics and Space Administration's (NASA's) Mars Science Laboratory (MSL) mission. Under the waiver, an inventory of existing national security PCVs will be converted to standard PCVs. Both types of PCVs are currently approved for use by the Office of Nuclear Energy. LLNL has previously reviewed the national security PCVs under Mound 1KW Package Safety Analysis Report for Packaging, Addendum No. 1, Revision c, dated June 2007 (Addendum 1). The safety analysis of the package is documented in the Safety Analysis Report for Packaging (SARP) for the Mound 1KW Package (i.e., the Mound 1KW SARP, or the SARP) where the standard PCVs have been reviewed by LLNL. The Mound 1KW Package is certified by DOE Certificate of Compliance (CoC) number USA/9516/B(U)F-85 for the transportation of Type B quantities of plutonium heat source material. The waiver requests an exemption, claiming safety equivalent to the requirements specified in 10 CFR 71.12, Specific Exemptions, and will lead to a letter amendment to the CoC. Under the waiver, the Office of Radioisotope Power Systems, NE-34, is seeking an exemption from 10 CFR 71.19(d)(1), Previously Approved Package,[5] which states: '(d) NRC will approve modifications to the design and authorized contents of a Type B package, or a fissile material package, previously approved by NRC, provided--(1) The modifications of a Type B package are not significant with respect to the design, operating characteristics, or safe performance of the containment system, when the package is subjected to the tests specified in {section}71.71 and 71.73.' The LLNL staff had previously reviewed a request from Idaho National Laboratory (INL) to reconfigure national security PCVs to standard PCVs. With a nominal 50% reduction in both the height and the volume, the LLNL staff initially deemed the modifications to be significant, which would not be allowed under the provisions of 10 CFR 71.19(d)(1)--see above. As a follow-up, the DOE requested additional clarification from the Nuclear Regulatory Commission (NRC). The NRC concluded that the reconfiguration would be a new fabrication, and that an exemption to the regulations would be required to allow its use, as per the requirements specified in 10 CFR 71.19(c)(1), Previously Approved Package: '(c) A Type B(U) package, a Type B(M) package, or a fissile material package previously approved by the NRC with the designation '-85' in the identification number of the NRC CoC, may be used under the general license of {section}71.17 with the following additional conditions: (1) Fabrication of the package must be satisfactorily completed by December 31, 2006, as demonstrated by application of its model number in accordance with 71.85(c).' Although the preferred approach toward the resolution of this issue would be for the applicant to submit an updated SARP, the applicant has stated that the process of updating the Model Mound 1KW Package SARP is a work that is in progress, but that the updated SARP is not yet ready for submittal. The applicant has to provide a submittal, proving that the package meets the '-96' requirements of International Atomic Energy Agency (IAEA) Safety Standards Series No. TS-R-1, in order to fabricate approved packagings after December 31, 2006. The applicant has further stated that all other packaging features, as described in the currently approved Model Mound 1KW Package SARP, remain unchanged. This report documents the LLNL review of the waiver request. The specific review for each SARP Chapter is documented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Review Report for the Justification for Shipment of Sodium-Bonded Carbide Fuel Pins in the T-3 Cask

This report documents the review of the Fluor Submittal (hereafter, the Submittal), prepared by Savannah River Packaging Technology (SRPT) of Savannah River National Laboratory (SRNL), at the request of the Department of Energy's (DOE) Richland Operations Office, for the shipment of unirradiated and irradiated sodium-bonded carbide fuel pins. The sodium-bonded carbide fuel pins are currently stored at the Fast Flux Test Facility (FFTF) awaiting shipment to Idaho National Laboratory (INL). Normally, modified contents are included into the next revision of the SARP. However, the contents, identified to be shipped from FFTF to Idaho National Laboratory, are a one-way shipment of 18 irradiated fuel pins and 7 unirradiated fuel pins, where the irradiated and unirradiated fuel pins are shipped separately, and can be authorized with a letter amendment to the existing Certificate of Compliance (CoC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗