Search NASASearch

Engineering topics

Westbrook, R. M.

Publications and source records attributed to Westbrook, R. M..

Using SAW Resonators in RF Oscillators

Surface-acoustic-wave (SAW) resonators used as frequency-determining elements in radio-frequency oscillators circuits. Oscillators are frequencymodulated, phase-modulated, or pulse-modulated. SAW resonators are especially applicable to low-power subminiature applications, such as biotelemetry and wind-tunnel instrumentation, where they advantageously replace crystals. Resonators are smaller than crystals and very thin--advantage where small package size is important.

Westbrook, R. M.

Compact, Rugged Temperature Recorder

Solid-state temperature recorder is compact, lightweight, and rugged. Records 2,048 temperature readings over period of up to nearly a year and retains them at least another 4 months using batteries. Battery-operated recorder has no moving parts--is completely solid-state electronic.

Westbrook, R. M.

A solid-state digital temperature recorder for space use

A solid-state, digital, temperature recorder has been developed for use in space experiments. The recorder is completely self-contained and includes a temperature sensor; all necessary electronics for signal conditioning, processing, storing, control and timing; and a battery power supply. No electrical interfacing with the particular spacecraft on which the unit is used is required. The recorder is small, light, and sturdy, and has no moving parts. It uses only biocompatible materials and has passed vibration and shock spaceflight qualification tests. The unit is capable of storing 2048, -10 to +45 C, 8-bit temperature measurements taken at intervals selectable by factors of 2 from 1.875 to 240 min; data can be retained for at least 6 months. The basic recorder can be simplified to accommodate a variety of applications by adding memory to allow more data to be recorded, by changing the front end to permit measurements other than temperature to be made, and by using different batteries to realize various operating periods. Stored flight data are read out from the recorder by means of a ground read-out unit.

Westbrook, R. M.

Heart rate, multiple body temperature, long-range and long-life telemetry system for free-ranging animals

The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.

Lund, G. F.

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.

Wideband EMG telemetry system

Miniature, individual crystal-controlled RF transmitters located in EMG pressure sensors simplifies multichannel EMG telemetry for electronic gait monitoring. Transmitters which are assigned operating frequencies within 174 - 216 MHz band have linear frequency response from 20 - 2000 Hz and operate over range of 15 m.

Rosatino, S. A.

A multichannel biotelemetry transmitter utilizing a PCM subcarrier

Making use of the currently available integrated circuits, a miniature PCM telemetry system operating from one miniature 9-volt battery and drawing less than 5 milliamps has been constructed. The use of this PCM telemetry signal not only provides accurate data transmission, but requires a minimum of RF bandwidth. The serial format that results from multiplexing the input data allows the use of a single channel recorder with its cost savings over a multichannel tape recorder. An additional benefit of the PCM encoding is that the data is in digital format and is directly suitable for computer use.

Fryer, T. B.

Narrowband, crystal-controlled biomedical telemetry system

Telemetry system utilizing miniature, single-channel, crystal-controlled transmitter is described suitable for biomedical applications. Receiver used in conjunction with transmitter is narrowband superheterodyne FM receiver with crystal control in both conversion stages.

Westbrook, R. M.

Use of implantable telemetry systems for study of cardiovascular phenomena.

Preliminary observations of cardiovascular function have been made in four chimpanzees using multichannel implantable units. Measurements of right- and left-sided pressures were periodically made in these animals over a four-month period, including continuous observations for selected 24-hour periods. Pressures recorded with animals in an awake, unanesthetized, unrestrained state were much lower than pressures reported for restrained animals in similar situations. Diurnal variations of pressure tended to occur, but were not as clear-cut as those reported to occur for humans. The ability to implant a transmitter chronically and receive useful multichannel information in the chimpanzee encourages the future use of such implant devices as part of the control system for an artificial heart or directly for use in man.

Sandler, H.

Single and multichannel implanted telemetry systems.

Description of improved single-channel and multichannel telemetry systems designed for measurements of single and multiple physiological parameters, respectively, with adequate accuracy. The systems include a single-channel biopotential transmitter, a temperature transmitter, a pressure transmitter, and a multichannel transmitter for implant telemetric applications.

Sandler, H.

A narrowband, crystal controlled biomedical telemetry system.

A miniature, single-channel, crystal-controlled transmitter has been developed for biomedical applications. A narrow-band frequency modulation (plus or minus 7 kHz) of the RF is used to achieve maximum operating range with minimum transmitting power. The radiated power is limited to stay within the 50 microvolts/m at 15 m FCC requirement for low-power transmitters in the 88- to 108-MHz band. This technique offers a number of advantages. First only manufacturer's type approval is required for the device and the user does not need a license. Second maximum operating range can be achieved within the FCC power limitations by using a narrow-band that is consistent with the required medical information bandwidth. A third advantage in using the 88- to 108-MHz band is that the commercial FM stations are relatively widely spaced and carefully regulated so that by selecting the transmitter's frequency in the guard band between stations, minimum interference from other transmitter sources is encountered.

Westbrook, R. M.

Constant-amplitude RC oscillator

Sinusoidal oscillator has a frequency determined by resistance-capacitance /RC/ values of two charge control devices and a constant-amplitude voltage independent of frequency and RC values. RC elements provide either voltage-control, resistance-control, or capacitance-control of the frequency.

Kerwin, W. J.

Helmet system broadcasts electroencephalograms of wearer

EEG monitoring system consisting of nonirritating sponge-type electrodes, amplifiers, and a battery-powered wireless transmitter, all mounted in the subjects helmet, obtains electroencephalograms /EEGs/ of pilots and astronauts performing tasks under stress. After a quick initial fitting, the helmet can be removed and replaced without adjustments.

Westbrook, R. M.