Cooled Gas Turbine and Combined Cycle Analysis for NH 3 -CH 4 Fuel Mixes (Up to 100% NH 3 )

In this study, a cooled gas turbine (GT) analysis was conducted for varying levels of ammonia (NH 3 ) blends with methane. The ultimate goal is to have a gas turbine design that can be used for all the fuel blends (including 100% NH 3 ) without any changes to the system. The technological developments in the cooling system, gas turbine design, and materials that will be required for NH 3 combustion were identified and analyzed in this study to develop an advanced gas turbine design for NH 3 fuels. The study includes a combined cycle performance analysis with the NH 3 fuel blends using the advanced gas turbine design developed in this study. A techno-economic analysis was conducted for analyzing the impact of the NH 3 fuels on the levelized cost of electricity and cost sensitivities to fuel price and capacity factor.

20 FOSSIL-FUELED POWER PLANTS↗

Cooled Gas Turbine and Combined Cycle Analysis for H 2 -CH 4 Fuel Mixes (Up to 100% H 2 )

In this study, a cooled gas turbine analysis was conducted for varying levels of hydrogen (H 2 ) blends with the natural gas. The ultimate goal is to have a gas turbine design that can be used for all the fuel blends (including 100% H 2 ) without any changes to the system. The technological developments in the cooling system, gas turbine design and materials that will be required for H 2 combustion were identified and analyzed in this study to develop an advanced gas turbine design for H 2 fuels. The study includes a combined cycle performance analysis with the H 2 fuel blends using the advanced gas turbine design developed in this study. A techno-economic analysis was conducted for analyzing the impact of the H 2 fuels on the levelized cost of electricity and cost sensitivities to fuel price and capacity factor.

03 NATURAL GAS↗

DPE Techno-Economic Analyses

This National Energy Technology Laboratory (NETL) report presents the results of an extensive set of techno-economic analyses for several open-cycle coal fuel oxy-fired direct power extraction (DPE) concepts. These power cycles make use of a conducting plasma accelerated through a magnetic field to generate direct current directly without the need for moving parts. Similar to gas turbines, the efficiency of the power cycle increases with increasing working fluid temperature and typically, plasma temperatures are much higher than the inlet temperature of even the most advanced gas turbine available today, affording the opportunity for very high cycle efficiencies. Most of the study uses high-fidelity models to assess a coal-fueled oxy-combustion DPE system with an AUSC steam bottoming cycle. Two baseline configurations were explored, one with relatively conservative operating point parameters and another with relatively aggressive operating point parameters. Additional analysis on the high-fidelity models as well as reduced order models were performed to analyze the cost and performance potential more thoroughly for the baseline systems and to compare their performance to two alternate open-cycle DPE systems.

30 DIRECT ENERGY CONVERSION↗

Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity

This revised report presents an independent assessment of the cost and performance of select fossil energy power systems—integrated gasification combined cycle (IGCC), pulverized coal (PC), and natural gas combined cycle (NGCC) plants—using a systematic, transparent technical and economic approach. The cost and performance of fossil fuel-based generation technologies represented in this report (and the series at large) are important inputs to assessments and determinations of technology combinations to be utilized to meet the projected demands of future power markets. In addition to informing technology comparisons, the reference plant configurations found in this report provide perspective for regulators and policy makers. From a research and development perspective, this report is used to assess goals and metrics and to provide a consistent basis for comparing developing technologies.

01 COAL, LIGNITE, AND PEAT↗

Advanced Turbine Airfoils for Efficient CHP Systems: Energy Storage Integration Analysis

This report documents the energy storage systems (ESS) integration portion of the work conducted under the Office of Energy Efficiency and Renewable Energy (EERE) advanced Manufacturing Office (AMO) Lab Call DE-LC-000L059 project titled "Advanced Turbine Airfoils for Efficient CHP Systems." The objective of this work is to analyze the previously-developed combined heat and power (CHP) plant with the upgraded gas turbine to include an ESS to improve the operational flexibility. The analysis includes identifying a candidate CHP configuration for the ESS integration and identifying possible storage systems to be integrated. A qualitative analysis was made to down select possible storage technologies and a techno-economic analysis (TEA) was made for the CHP system with the selected storage technology.

20 FOSSIL-FUELED POWER PLANTS↗

Performance and Cost Potential for Exemplar Direct Supercritical Carbon Dioxide Natural Gas Plants

This report presents the techno-economic analysis (TEA) optimization results of natural gas-fired utility-scale power plants based on the direct supercritical carbon dioxide (sCO 2 ) power cycle. To identify optimum plant configuration, the study also considered three different cases (Case A, Case B, Case C) with varying levels of thermal integration with the plant air separation unit (ASU). A fourth case (Case D), which is based on a patent from 8 Rivers, was also considered and includes thermal integration with the ASU as well as compressed recycle carbon dioxide (CO 2 ) gas. The four direct sCO 2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on an F-class gas turbine with carbon capture and storage (CCS). LCOE of the direct sCO 2 plants is 13.5–17.2 percent higher than the reference NGCC plants with CCS due to higher capital costs associated with the ASU and sCO 2 power block. Recuperators make up over 50 percent of the power cycle costs. Consequently, any research and development (R&D) efforts to reduce the recuperator capital costs will be beneficial for the technology commercialization. The study also investigated the impact of co-firing landfill gas (LFG) and natural gas on plant efficiency, LCOE, and CO 2 emissions. Increasing the LFG co-firing from 0 percent to 50 percent (mass basis), decreased the plant efficiency by 0.3 percentage points and increased the LCOE by 3 percent. Due to high inherent CO 2 capture rates, direct sCO 2 plants have strong potential to achieve net-zero CO 2 emissions with LFG and natural gas co-firing.

03 NATURAL GAS↗

Adiabatic Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for an adiabatic cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Direct Dry Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Indirect Dry Cooling System Spreadsheet Model for sCO2

The attached cost and performance spreadsheet model is for an indirect dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Wet Cooling Tower Cooling System Spreadsheet Model for sCO2

The attached cost and performance spreadsheet model is for a wet cooling tower system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Performance and Cost Assessment of a Natural Gas-Fueled Direct sCO 2 Power Plant

This final report details the cost and performance baseline developed at NETL for a natural gas-fueled direct sCO 2 plant, which holds promise as an efficient, cost-effective method of power production with carbon capture and storage (CCS). The steady state plant model includes turbine cooling flows based on a semi-empirical cooling model, and thermal integration with the air separation unit and oxygen compression train. Discussion of the performance of the baseline plant design is followed by details on the costing methodology, overall plant capital cost, and resulting cost of electricity (COE). Performance results yield a baseline sCO 2 plant thermal efficiency of 48.2% (HHV) with 98.2% carbon capture, an improvement over the reference NGCC plant with CCS (45.7% and 90.7% carbon capture). Cost analyses yield a 5% reduction in COE versus the NGCC plant, albeit with significant uncertainty. Finally, the effects of incomplete combustion on the overall plant performance are assessed.

03 NATURAL GAS↗

Supercritical Carbon Dioxide (SCO 2 ) Cycle as an Efficiency Improvement Opportunity for Air-fired Coal Combustion

Coal has been historically the fuel to satisfy the United States’ need for baseload electricity generation. Increasingly stringent environmental regulations (specifically uncertainty for CO 2 emission regulations), are forcing the electric power industry to scrutinize the long-term viability of new and existing coal-fueled assets. The development of advanced, higher efficiency coal power generation technologies leading to reductions in CO 2 and other emissions and competitive costs are one avenue to address these concerns. A goal of this study was initially to identify one or more conceptual designs for a coal-fired power plant that could meet the existing “Carbon Pollution Standard (CPS) for New Power Plants” without dedicated CO 2 capture equipment. Since the EPA proposals are still under the review process, this report uses the current limits. Additional goals include: sCO 2 cycles systems that achievie an efficiency > 46.7 % HHV and a cost of electricity of < $82.3/MWh.

01 COAL, LIGNITE, AND PEAT↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO 2 Brayton Cycle - Report

This report presents the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO 2 ) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO 2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

20 FOSSIL-FUELED POWER PLANTS↗

Performance and Cost Assessment of a Coal Gasification Power Plant Integrated with a Direct-Fired sCO 2 Brayton Cycle

The objective of this study is to develop a cost and performance baseline for a coal syngas-fueled, direct-fired supercritical carbon dioxide (sCO2) power plant using coal gasification, and to analyze the sensitivity of its cost and performance to variations in operating parameter and cost assumptions. The study results yield a sCO2 baseline plant efficiency of 37.7% (HHV), with 97.6% carbon capture at 99.8% purity, much higher than the reference integrated gasification combined cycle (IGCC) plant using the same Shell gasifier (31.2% efficiency, 90% carbon capture). The economic analysis estimates a cost of electricity (COE) of $137/MWh for the mature, commercial-scale sCO2 plant (without CO2 transport and storage costs), yielding a 10% reduction in COE from the reference IGCC case. These results demonstrate the significant potential of direct sCO2 power cycles for achieving DOE’s transformational power generation goals for coal-fueled power plants with carbon capture and storage.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluation of Property Methods for Modeling Direct-Supercritical CO2 Power Cycles

Direct supercritical CO2 (sCO2) power cycles combust natural gas or syngas with oxygen in a high pressure, heavily-diluted sCO2 environment, and are an efficient and potentially cost-effective method of capturing CO2 from fossil-fueled power plants. The cycle thermal efficiency varies with the proximity of the operating conditions to the CO2 critical point, as well as to the level of working fluid dilution by minor components, thus it is crucial to correctly model the thermo-physical properties of these sCO2 mixtures. This paper presents a quantitative evaluation of ten different property methods that can be used for modeling direct sCO2 cycles in Aspen Plus. These property methods are assessed against several mixture property measurements, and offer a relative comparison to the accuracy obtained with REFPROP, the standard for analyzing high purity indirect sCO2 systems. The Lee-Kessler-Plocker Equation of State is recommended if REFPROP cannot be used.

direct sCO2↗