Search NASA⌕ Search

Engineering topics

White, Robert (ORCID:0000000252084061)

Publications and source records attributed to White, Robert (ORCID:0000000252084061).

Advancing Our Understanding of System Availability through the PV Fleet Performance Data Initiative

The PV Fleet Performance Data Initiative partners with photovoltaic (PV) fleet owners to collect time-series data of PV production data and publishes aggregated anonymized results of system performance metrics. With an extensive dataset drawn from over 2,200 PV systems across the United States, comprising 8.5 GW and 24,000 separate inverter data channels, this initiative aims to ensure that systemic risks in the US PV fleet are detected. The current work explores system availability, revealing a pronounced dependence on time, especially within the initial 6 months of system performance. Following this start-up period, the average system availability stabilizes. Statistical analyses illustrate a median (P5O) monthly availability of 0.991 and a dependence on system size with a negative trend in availability with increasing system size. This finding indicates that larger systems experience lower availability compared to their smaller counterparts.

inverter availability↗

Quantifying Error in Photovoltaic Installation Metadata: Preprint

In this research, we quantify the level of metadata error for a fleet of 2860 photovoltaic (PV) systems, using metadata values provided by fleet owners. Using satellite imagery and time series analysis techniques available in open-source Python packages Panel-Segmentation and PVAnalytics, respectively, we evaluate the accuracy of PV system metadata such as location, azimuth, tilt, and mounting configuration (fixed tilt vs. tracking). We find that approximately 75% of provided latitude-longitude coordinates are within 190 meters of the actual solar installation. We were unable to link 7.8% of latitude-longitude coordinates to any solar installation via satellite imagery analysis. We evaluate the level of error in owner-provided mounting configuration (fixed tilt vs. single-axis tracking), finding only 8 systems with an incorrect mounting configuration. When evaluating azimuth and tilt parameters, we find that approximately 64% of the data is correct, with data for 860 systems (approximately 30%) not provided by system owners. To illustrate the importance of having correct solar metadata, we evaluate how incorrect metadata affects solar performance estimates by modeling system AC energy output at ground-truth vs. incorrect latitude-longitude coordinates, mounting configurations, and azimuth-tilt configurations. Energy output estimates can vary significantly if incorrect metadata parameters are used, with incorrect mounting configuration leading to the largest discrepancy with over 20% variation in expected energy output.

azimuth↗

PV Reliability and Resilience in Challenging Climates

Challenging climates for Photovoltaics are usually based on climate classification. However, extreme weather events such as high wind, flooding, large hail, extreme snow etc. have become more ubiquitous globally. To study the impact of extraordinary weather events on PV reliability we used two of the largest databases in the USA. First, the National Oceanic and Atmospheric Administration (NOAA) database on extreme weather and secondly, the PV Fleet Data Initiative where we have collected high-resolution PV performance data of more than 8 gigawatts or about 6-7% of all commercial and utility systems in the USA. We analyzed almost 200 systems between 2008-20022 that were immediately impacted by these weather events. The immediate impact (outages) was determined to be about 1% of or a median of approximately 3 days of annual lost production. However, the risk these events pose is exemplified by a long tail where 0.4 % of all systems lost more than 2 weeks annual production. We also found a threshold for high wind (90 km/hr) and hail (25mm), above which we observed significantly higher degradation implying long-term damage to the systems. In addition, we are using satellite imagery to quantify visible damage to PV plants. Finally, we share module, design and installation lessons from some observed case studies to improve extreme weather resilience for PV power systems.

degradation↗

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗

Extreme Weather Events and PV Systems Impact

The impact of extreme weather events on PV performance was studied by comparing the National Oceanic and Atmospheric Administration database on severe weather with the National Renewable Energy Laboratory's (NREL) PV Fleet database on continuous PV performance. We identified 170 systems that were immediately impacted by weather events. These severe weather events lead to a median loss of only 1 % of annual production. However, flooding and high wind events were found to have an extremely long tail extending to 60 % loss, showing that these discrete events can pose a substantial risk to PV systems. Besides the short-term impact of lost production due to outages, we also found a statistically significant increased performance loss rate (PLR) for high wind events above 90 kilometer/hour, by comparing PLR before and after these events. Similarly, hail events caused higher PLR for hail sizes of and above 25 mm indicating that more stringent hail testing for PV modules is required. In addition, very high snow loads may also cause increased PLRs, but more data are required to better quantify the impact. These findings illustrate the substantial risk extreme weather events pose short-and long-term to fielded PV installations.

extreme weather↗

AI and ML Applications for PV Reliability and System Performance

This poster discusses AI and ML topics in PV reliability and system performance. In particular, automated metadata extraction and QA for fielded solar installations is covered for the PV Fleets Project. Additionally, statistical learning topics for the PVInsight Project are addressed, as well as development of the PV Validation Hub.

algorithm↗

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗