Search NASA⌕ Search

Engineering topics

White, Stephen

Publications and source records attributed to White, Stephen.

Fermilab s Transition to Token Authentication

Fermilab is the first High Energy Physics institution to transition from X.509 user certificates to authentication tokens in production systems. All of the experiments that Fermilab hosts are now using JSON Web Token (JWT) access tokens in their grid jobs. Many software components have been either updated or created for this transition, and most of the software is available to others as open source. The tokens are defined using the WLCG Common JWT Profile. Token attributes for all the tokens are stored in the Fermilab FERRY system which generates the configuration for the CILogon token issuer. High security-value refresh tokens are stored in Hashicorp Vault configured by htvault-config, and JWT access tokens are requested by the htgettoken client through its integration with HTCondor. The Fermilab job submission system jobsub was redesigned to be a lightweight wrapper around HTCondor. For automated job submissions a managed tokens service was created to reduce duplication of effort and knowledge of how to securely keep tokens active. The existing Fermilab file transfer tool ifdh was updated to work seamlessly with tokens, as well as the Fermilab POMS (Production Operations Management System) which is used to manage automatic job submission and the RCDS (Rapid Code Distribution System) which is used to distribute analysis code via the CernVM FileSystem. The dCache storage system was reconfigured to accept tokens for authentication in place of X.509 proxy certificates. As some services and sites have not yet implemented token support, proxy certificates are still sent with jobs for backwards compatibility but some experiments are beginning to transition to stop using them. There have been some glitches and learning curve issues but in general the system has been performing well and is being improved as operational problems are addressed.

Dykstra, David↗

Evaluation of a New Chemical Mechanism for 2-Amino-2-methyl-1-propanol in a Reactive Environment from CSIRO Smog Chamber Experiments

Amines are considered as an emerging class of atmospheric pollutants that are of great importance to atmospheric chemistry and new particle formation. As a typical amine, 2-amino-2-methyl-1-propanol (AMP) is one of the proposed solvents for capturing CO 2 from flue gas streams in amine-based post-combustion CO 2 capture plants, and it is expected to result in AMP emission and secondary products formation in the atmosphere. However, the current knowledge of its atmospheric chemistry and kinetics is poorly understood, particularly in a reactive environment. As such, in this work we used the CSIRO smog chamber to study the photo-oxidation of AMP in the presence of VOCs–NOx surrogate mixtures over a range of initial amine concentrations. O 3 formation was significantly inhibited when AMP was added to the surrogate VOCs–NOx mixtures, implying that AMP could alter known atmospheric chemical reaction pathways and the prevailing reactivity. Simultaneously, a large amount of AMP-derived secondary aerosol was formed, with a considerably high aerosol mass yield (i.e. ratio of aerosol formed to reacted AMP) of 1.06±0.20. Based on updated knowledge of its kinetics, oxidation pathways and product yields, we have developed a new mechanism (designated as CSIAMP-19) and integrated into the Carbon Bond 6 (CB6) chemical mechanism, and evaluated it against available smog chamber data. Compared with the existing AMP mechanism (designated as CarterAMP-08), the modified CB6 with CSIAMP-19 mechanism improves prediction against AMP–VOCs–NOx experiments across a range of initial AMP concentrations, within ±10% model error for gross ozone production. Our results contribute to scientific understanding of AMP photochemistry and to the development of the chemical mechanism of other amines. The updated AMP chemical reactions scheme can be further embedded into the chemical transport model for regional modelling scenarios where AMP-related emissions are of concern.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production Operations Management System (POMS) for Fermilab Experiments

The Production Operations Management System (POMS) software allows production teams and analysis groups across multiple Fermilab experiments to launch, modify and monitor large scale campaigns of related Monte Carlo or data processing jobs, and currently manages the majority of production computing of experiments at Fermilab.POMS provides a web service interface that enables automated job submission on distributed resources according to customers’ requests, as well as subsequent monitoring of those submissions as well as recovery of failed submissions, debugging and record keeping.POMS interfaces with existing HEP data access, processing, movement and monitoring tools at Fermilab, including Jobsub (for job submission), SAM (for data management), and Landscape (for monitoring), and in combination with them handles the creation of intermediate datasets of files for multistage campaigns.POMS visualizes these campaigns with an interactive GUI interface. An important feature of POMS is a one-to-one connection between the GUI campaign visualizer and a text based representation of the complete campaign configuration. An extensible library of template campaign configurations is available. The templates are user modifiable and map cleanly to and from the GUI description of the campaign.This paper will discuss the current usage, history, and some technical details of POMS, as well as planned future extensions, particularly interfacing with Rucio as well as SAM for file movement.

Mengel, Marc↗

Installing Deep Groundwater Monitoring Wells in a Volcanic Dominated Rift Basin: Los Alamos National Laboratory, New Mexico - 17594

Los Alamos National Laboratory (LANL, or the Laboratory) is located in northern New Mexico near the west margin of the Espanola Basin. LANL is underlain by a complex basin-fill sequence of alluvial fan deposits, volcanic tuff, basaltic and dacitic lavas, and riverine deposits. On-going environmental remediation and characterization activities have evolved to improve the performance of groundwater monitoring wells, ensuring they yield representative groundwater and core samples. Groundwater occurs as canyon-fill alluvial water, perched intermediate-depth water associated with the basalts and other local-scale perching horizons, and as a regional-scale aquifer that is the main water supply for the area. Anthropogenic contaminants are found in all three groundwater zones. The regional aquifer below LANL is nominally 1000-1400 feet below ground surface (bgs). Monitoring wells at the Laboratory, are therefore, among the deepest routinely installed in the US. Logistical challenges at LANL include steep terrain, widespread cultural sites, and threatened and endangered species habitat restrictions. Additionally, the cost of installing monitoring wells is high because of groundwater depths and the variable drilling techniques that are required to characterize and install wells in a complex geologic environment. A major challenge to the characterization approach at LANL has been to meet sample quality requirements while minimizing drilling costs. In the late 1990's threaded drill-casing was advanced by rotary drilling methods using compressed air as the only circulation fluid. This resulted in relatively low impacts to the geochemical integrity of rock and groundwater samples, but led to frequent episodes of stuck casing. Additional fluids were introduced to the air-rotary program, improving penetration rates, but also resulting in non-representative groundwater samples due to long-term impacts to the aquifer in the vicinity of the well screen. Mud-rotary drilling was incorporated into the program, but it also had significant long-term impacts on groundwater quality, and often inhibited identification of perched groundwater zones and accurate identification of the water table in the regional aquifer. Current drilling practice makes limited use of fluid additives (e.g. foam) to supplement air circulation methods in order to advance drill casing through the vadose zone. Starting about 100 feet above the water table, drill casing is advanced to the target horizon in the regional aquifer using only air and municipal water (when needed) for circulation. Additionally, the threaded drill casing couplings have been replaced with welded connections, significantly reducing the occurrence of stuck casing. Careful observations of water production and water levels during drilling, coupled with the ability to retract casing for video and geophysical logs, now allows for robust characterization of perched groundwater systems and accurate definition of the top of regional saturation. Recent advances in the drilling program include combined dual-rotary/sonic drilling to depths up to 1150 feet and dual-rotary casing advance at angles up to 25 deg. from vertical. The former allows for core collection with minimal fluid addition, thereby preserving pore water chemistry. The latter method allows for well installation into portions of the aquifer otherwise inaccessible due to constraints at the surface (e.g., cultural sites or topography). Similar to the development of drilling techniques, both well design and groundwater sampling system design have evolved throughout the program. Current well design emphasizes a minimal annulus of filter pack, maximum screen slot size based on formation sieve analyses, and thorough well development to mitigate formation damage due to drilling. To sample groundwater at multiple levels in the same well, earlier sampling systems included Westbay{sup R} multi-zone systems and dual-screen single-pump and dual-screen dual-pump systems designed in collaboration with Baski, Inc. These multi-zone sampling systems proved difficult to develop and maintain given the depth to groundwater, and most current well installations are configured with a single screen and a submersible pump. The ability to purge from a well-developed single-screen well has substantially improved the collection of representative groundwater samples. A carefully crafted groundwater characterization program in target aquifers at depths ranging from 1,000 to 1,400 feet bgs within a complex geologic setting, while also retaining the ability to collect representative core and groundwater samples, may have application at a number of sites throughout the environmental industry. Optimizing each well to meet program objectives while reducing total project costs benefits all environmental investigations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FIRST IMAGES FROM THE FOCUSING OPTICS X-RAY SOLAR IMAGER

The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload flew for the first time on 2012 November 2, producing the first focused images of the Sun above 5 keV. To enable hard X-ray (HXR) imaging spectroscopy via direct focusing, FOXSI makes use of grazing-incidence replicated optics combined with fine-pitch solid-state detectors. On its first flight, FOXSI observed several targets that included active regions, the quiet Sun, and a GOES-class B2.7 microflare. This Letter provides an introduction to the FOXSI instrument and presents its first solar image. These data demonstrate the superiority in sensitivity and dynamic range that is achievable with a direct HXR imager with respect to previous, indirect imaging methods, and illustrate the technological readiness for a spaceborne mission to observe HXRs from solar flares via direct focusing optics.

79 ASTRONOMY AND ASTROPHYSICS↗