Search NASASearch

Engineering topics

White, Victor

Publications and source records attributed to White, Victor.

At least 19 records

Optial Experiments and Model Validation of Perturbed Starshade Designs

Starshades are a leading technology to enable the direct detection and spectroscopic characterization of Earth- like exoplanets. Critical starshade technologies are currently being advanced through the S5 Project and at the Princeton starshade testbed. We report on the status of Milestone 2 of the S5 Project, optical model validation. We present results from optical experiments of starshades with intentional perturbations built into their design. These perturbations are representative of the type of perturbations possible in a flight design and serve as points of validation for dffraction models and error budgets. We show experimental results for two perturbed shapes, a mask with all petals shifted radially outward by 5 um and a mask with shallow sine waves built into two petals. We compare these data to outputs of the optical model and demonstrate better than 25% agreement. We also present images taken in crossed polarized light and use those data to constrain physical parameters of the optical edge. Bringing in previously obtained results for other perturbed shapes, we show an agreement between experiment and model of better than 25% and argue that this satisfies the Milestone 2 criteria.

Galvin, Michael

Validation of Diffraction Models With Experimental Results From the Princeton Starshade Testbed

Starshades are a leading technology to detect and characterize Earth-like exoplanets. In this paper we report on optical experiments of sub-scale starshades that advance critical starlight suppression technologies in preparation for the next generation of space telescopes. These experiments were conducted at the Princeton starshade testbed, an 80 m long enclosure testing 1/1000th scale starshades at a ight-like Fresnel number. In this paper we summarize recent updates made to the starshade testbed and optical model. We present results from recent experiments testing two starshade masks with intentional perturbations built into their shape. One of the perturbed masks has three petals that are shifted radially outward by 7-11 microns and the other mask has two petals shifted radially outward plus two petal edge segments displaced from their nominal position. We show the model agrees with experiment to better than 25% accuracy. These results are placed into context with previous experiments on perturbed shapes and progress made towards satisfying a critical milestone in advancing starshade technology to TRL 5.

Galvin, Michael

Fabrication of coronagraph masks and laboratory scale star-shade masks: characteristics, defects and performance

NASA WFIRST mission has planned to include a coronagraph instrument to find and characterize exoplanets. Masks are needed to suppress the host star light to better than 10-8 – 10-9 level contrast over a broad bandwidth to enable the coronagraph mission objectives. Such masks for high contrast coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, etc. We present the technologies employed at JPL to produce these pupil plane and image plane coronagraph masks, and lab-scale external occulter masks, highlighting accomplishments from the high contrast imaging testbed (HCIT) at JPL and from the high contrast imaging lab (HCIL) at Princeton University. Inherent systematic and random errors in fabrication and their impact on coronagraph performance are discussed with model predictions and measurements.

Casey Wilson, Robert

Dynamic Testbed Demonstration of WFIRST Coronagraph Low Order Wavefront Sensing and Control (LOWFS/C)

To maintain the required performance of WFIRST Coronagraph in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The LOWFS/C uses a Zernike wavefront sensor (ZWFS) with the phase shifting disk combined with the starlight rejecting occulting mask. For wavefront error corrections, WFIRST LOWFS/C uses a fast steering mirror (FSM) for line-of-sight (LoS) correction, a focusing mirror for focus drift correction, and one of the two deformable mirrors (DM) for other low order wavefront error (WFE) correction. As a part of technology development and demonstration for WFIRST Coronagraph, a dedicated Occulting Mask Coronagraph (OMC) testbed has been built and commissioned. With its configuration similar to the WFIRST flight coronagraph instrument the OMC testbed consists of two coronagraph modes, Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC), a low order wavefront sensor (LOWFS), and an optical telescope assembly (OTA) simulator which can generate realistic LoS drift and jitter as well as low order wavefront error that would be induced by the WFIRST telescope’s vibration and thermal changes. In this paper, we will introduce the concept of WFIRST LOWFS/C, describe the OMC testbed, and present the testbed results of LOWFS sensor performance. We will also present our recent results from the dynamic coronagraph tests in which we have demonstrated of using LOWFS/C to maintain the coronagraph contrast with the presence of WFIRST-like line-of-sight and low order wavefront disturbances.

Zhou, Hanying

Electrospray Thruster Performance with Microfabricated Emitter Arrays and Indium Propellant

The feasibility of a microfabricated indium-fueled electrospray thruster with excellent performance was demonstrated. High efficiency electrospray thrusters with microfabricated components are under development for very compact, distributable propulsion systems that can be employed on both very small and large spacecraft with 10X improvement over SOA in mass, volume and specific impulse The critical components of this technology are the microfabricated emitter arrays and the capillary force driven indium feed system. Grey scale electron-beam lithography patterning and reactive ion dry etching provided the required micron-scale etch precision and uniformity across an array of 400 emitters in 1 cm2. Initial tests of single microfabricated silicon emitters demonstrated better performance than industry standard single emitters and the performance required to achieve 200 micronewtons when scaled up to a thruster with 400 emitters in 1 cm2. Arrays of emitters tested in a preliminary prototype Microfluidic Electrospray Propulsion (MEP) thruster assembly demonstrated stable performance at estimated thrust levels of 5, 50, and 120 µN at extraction voltages less than 4 kV. Current stability was within 0.15 % at 120 µN with only 1.5% of the emitter current collected by the extractor electrode. Post-test inspections revealed that more than 99% of the 400 emitters were electrospraying during the test. Specific impulse was estimated to be >3100 s from measurements of total charge and consumed indium mass at an emitter voltage of 1470 V. The results of this investigation suggest that microfabricated indium electrospray thruster technology is both feasible and capable of excellent performance as a highly compact microthruster.

Marrese-Reading, Colleen M.

Silicon Emitter Needle and Array Design for Indium Electrospray Arrays for Spacecraft Propulsion

A design for silicon microfabricated emitter arrays was developed for electrospray thrusters for indium propellant in compact architectures with scalable thrust, low mass and volume, high specific impulse and high efficiency operation. The design elements include tip height, height uniformity across the array, tip radii, axial groove depth, tip angle, emitter shank sidewall angle and number of emitters. They were derived from commercial liquid metal ion source designs and modeling, fabrication and test results. The most critical results of the emitter array design analysis suggest that microfabricated silicon emitter array emitters should have a height greater than 280 microns with a height uniformity of +/-10 microns, a tip half angle of 49° for uniform turn-on voltages and current across the array, low beam divergence and high mass utilization efficiency. Elements of the design were fabricated and demonstrated in single emitter and in 400 element emitter arrays to validate the design, fabrication and performance capability. The design height and uniformity of arrays was demonstrated for 85% of the emitters in a prototype array. Required tip and sidewall angles and groove depths have been microfabricated. Single microfabricated silicon emitters demonstrated better performance in current and voltage characteristics than commercially available liquid metal ion sources. Microfabricated emitters and arrays demonstrated the required current and stability performance to enable the MEP thruster development for indium propellant.

Marrese-Reading, Colleen M.

Exoplanet Coronagraph Shaped Pupil Masks and Laboratory Scale Star Shade Masks: Design, Fabrication and Characterization

Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10 -9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

black silicon

High Contrast Internal and External Coronagraph Masks Produced by Various Techniques

Masks for high contrast internal and external coronagraphic imaging require a variety of masks depending on different architectures to suppress star light. Various fabrication technologies are required to address a wide range of needs including gradient amplitude transmission, tunable phase profiles, ultra-low reflectivity, precise small scale features, and low-chromaticity. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks, and lab-scale external occulter type masks by various techniques including electron beam, ion beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each. Further development is in progress to produce circular masks of various kinds for obscured aperture telescopes.

Phase Induced Amplitude Apodization Complex Mask C

Stereo Imaging Miniature Endoscope

Stereo imaging requires two different perspectives of the same object and, traditionally, a pair of side-by-side cameras would be used but are not feasible for something as tiny as a less than 4-mm-diameter endoscope that could be used for minimally invasive surgeries or geoexploration through tiny fissures or bores. The proposed solution here is to employ a single lens, and a pair of conjugated, multiple-bandpass filters (CMBFs) to separate stereo images. When a CMBF is placed in front of each of the stereo channels, only one wavelength of the visible spectrum that falls within the passbands of the CMBF is transmitted through at a time when illuminated. Because the passbands are conjugated, only one of the two channels will see a particular wavelength. These time-multiplexed images are then mixed and reconstructed to display as stereo images. The basic principle of stereo imaging involves an object that is illuminated at specific wavelengths, and a range of illumination wavelengths is time multiplexed. The light reflected from the object selectively passes through one of the two CMBFs integrated with two pupils separated by a baseline distance, and is focused onto the imaging plane through an objective lens. The passband range of CMBFs and the illumination wavelengths are synchronized such that each of the CMBFs allows transmission of only the alternate illumination wavelength bands. And the transmission bandwidths of CMBFs are complementary to each other, so that when one transmits, the other one blocks. This can be clearly understood if the wavelength bands are divided broadly into red, green, and blue, then the illumination wavelengths contain two bands in red (R1, R2), two bands in green (G1, G2), and two bands in blue (B1, B2). Therefore, when the objective is illuminated by R1, the reflected light enters through only the left-CMBF as the R1 band corresponds to the transmission window of the left CMBF at the left pupil. This is blocked by the right CMBF. The transmitted band is focused on the focal plane array (FPA).

Bae, Youngsam

Miniature Scroll Pumps Fabricated by LIGA

Miniature scroll pumps have been proposed as roughing pumps (low - vacuum pumps) for miniature scientific instruments (e.g., portable mass spectrometers and gas analyzers) that depend on vacuum. The larger scroll pumps used as roughing pumps in some older vacuum systems are fabricated by conventional machining. Typically, such an older scroll pump includes (1) an electric motor with an eccentric shaft to generate orbital motion of a scroll and (2) conventional bearings to restrict the orbital motion to a circle. The proposed miniature scroll pumps would differ from the prior, larger ones in both design and fabrication. A miniature scroll pump would include two scrolls: one mounted on a stationary baseplate and one on a flexure stage (see figure). An electromagnetic actuator in the form of two pairs of voice coils in a push-pull configuration would make the flexure stage move in the desired circular orbit. The capacitance between the scrolls would be monitored to provide position (gap) feedback to a control system that would adjust the drive signals applied to the voice coils to maintain the circular orbit as needed for precise sealing of the scrolls. To minimize power consumption and maximize precision of control, the flexure stage would be driven at the frequency of its mechanical resonance. The miniaturization of these pumps would entail both operational and manufacturing tolerances of <1 m. Such tight tolerances cannot be achieved easily by conventional machining of high-aspect-ratio structures like those of scroll-pump components. In addition, the vibrations of conventional motors and ball bearings exceed these tight tolerances by an order of magnitude. Therefore, the proposed pumps would be fabricated by the microfabrication method known by the German acronym LIGA ( lithographie, galvanoformung, abformung, which means lithography, electroforming, molding) because LIGA has been shown to be capable of providing the required tolerances at large aspect ratios.

Wiberg, Dean

Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

Willis, Peter

Pneumatic Haptic Interfaces

An instrumentation system for direct measurement of the thermal conductivity of a small sample of a highly insulating material has been devised. As used here, (1) "small" signifies having dimensions of the order of two centimeters - significantly less than the sizes of specimens for which prior devices for direct measurement of thermal conductivity have been designed; and (2) "highly insulating" signifies having thermal conductivity of the order of that of air. The heart of the system is an assembly that includes two copper disks - one electrically heated, the other cooled with chilled water. The disks are separated by a guard ring made of strong, thermally insulating polymethacrylamide foam. The sample fits between the copper disks and within the ring (see figure). Matched thermocouples are used to measure the temperatures of the heated and cooled disks. The heated and cooled disks are affixed to larger foam disks, and the essentially still air in the gap between the larger disks insulates the sides of the specimen. This air gap region can be further divided by extending the foam ring into the gap region. The entire assembly as described thus far is lightly clamped together by means of nylon threaded rods and is placed inside a cylindrical chamber wherein the temperature is maintained at a set value (typically, 25 C).

Bae, Sam Y.

Micromachined Slits for Imaging Spectrometers

Slits for imaging spectrometers can now be fabricated to a precision much greater than previously attainable. What makes this possible is a micromachining process that involves the use of microlithographic techniques.

Wilson, Daniel

Hydroxide-Assisted Bonding of Ultra-Low-Expansion Glass

A process for hydroxide-assisted bonding has been developed as a means of joining optical components made of ultra-low-expansion (ULE) glass, while maintaining sufficiently precise alignment between. The process is intended mainly for use in applications in which (1) bonding of glass optical components by use of epoxy does not enable attainment of the required accuracy and dimensional stability and (2) conventional optical contacting (which affords the required accuracy and stability) does not afford adequate bond strength. The basic concept of hydroxide-assisted bonding is not new. The development of the present process was prompted by two considerations: (1) The expertise in hydroxide-assisted bonding has resided in very few places and the experts have not been willing to reveal the details of their processes and (2) data on the reliability and strength attainable by hydroxide-assisted bonding have been scarce.

Abramovici, Alexander