Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

High Multiplication Neutron Noise Measurements Using the 7uPCX Assembly

The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of New MCNP6.3 Features for Critical and Subcritical Benchmark Simulations [Slides]

A separate MCNP6.3 V&V document reports on all the default calculations for all test suites was introduced. Here, we look at new optional features of the MCNP6.3 code. Then, Fission-matrix-based options with Convergence and population testing and Automated acceleration of the fission source and Doppler Broadening Resonance Correction and HDF5 Particle Track Output (PTRAC) and Validation benchmarks: criticality, Rossi-α, and subcritical multiplication. All the new MCNP6.3 options give statistically equivalent results and should be considered for default usage in criticality and subcritical multiplication calculation work. Discussed are two separate papers at the upcoming 2023 International Conference on Nuclear Criticality Safety (ICNC 2023) that give more details on the results presented here.

97 MATHEMATICS AND COMPUTING↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Integral Experiment Execution (CED-3b Report)

This report documents the experimental configurations and measurements for IER-518: Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments. These measurements involved a series of subcritical configurations at the Sandia Critical Experiments (SCX) facility at Sandia National Laboratories (SNL). The purpose of these measurements was to produce time tagged neutron count data of configurations that exceed a subcritical multiplication of 20, which is the high end of the fundamental physics benchmarks currently available in the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP). These measurements leverage experimental configurations 1 and detector systems 2 from previously accepted ICSBEP benchmark evaluations, allowing evaluations of these measurements to be performed at greatly reduced cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗