Search NASA⌕ Search

Engineering topics

Whyatt, Greg A.

Publications and source records attributed to Whyatt, Greg A..

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrocatalytic Hydrogenation of Biomass-Derived Organics: A review

Sustainable energy generation calls for a shift away from centralized, high-temperature, energy-intensive processes to decentralized, low-temperature conversions that can be powered by electricity produced from renewable sources. Electrocatalytic conversion of biomass-derived feedstocks would allow carbon recycling of distributed, energy-poor resources in the absence of sinks and sources of high-grade heat. Selective, efficient electrocatalysts that operate at low temperatures are needed for electrocatalytic hydrogenation (ECH) to upgrade the feedstocks. For effective generation of energy-dense chemicals and fuels, two design criteria must be met: (i) a high H:C ratio via ECH to allow for high-quality fuels and blends, and (ii) a lower O:C ratio in the target molecules via electrochemical decarboxylation/deoxygenation to improve the stability of fuels and chemicals. The goal of this review is to determine whether the following questions have been sufficiently answered in open literature, and if not, what additional information is required: (1) What organic functionalities are accessible for electrocatalytic hydrogenation under a set of reaction conditions? How do substitutions and functionalities impact the activity and selectivity of ECH? (2) What material properties cause an electrocatalyst to be active for ECH? Can general trends in ECH be formulated based on the type of electrocatalyst? (3) What is the impact of reaction (electrolyte concentration, pH, operating potential) and reactor type conditions?

Catalysts, redox reactions, hydrocarbons, Aromatic↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A single-component water-lean post-combustion CO 2 capture solvent with exceptionally low operational heat and total costs of capture – comprehensive experimental and theoretical evaluation

A comprehensive evaluation of a recently developed water-lean amine-based solvent, namely N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (2-EEMPA), has been performed to analyze its post-combustion CO 2 capture performance. This evaluation comprises (1) fundamental characterization of the solvent–CO 2 interaction using vapor–liquid equilibria, kinetics and viscosity measurements; (2) process characterization of the CO 2 capture performance as measured in a laboratory scale continuous flow system and via Aspen Plus® simulation using a flue gas simulant; as well as (3) a full techno economic analysis of the capture process at industrial scale with corresponding projections of critical metrics. This paper summarizes the many parts of this comprehensive evaluation and shows how the various parts come together to empower validated conclusions about its process performance. Notably, it is projected that this solvent can operate at a regeneration heat rate of 2.0 GJ per tonne CO 2 for post-combustion capture, and at a total cost of capture of $50.6/tonne CO 2 . Overall, with further process optimization significant reductions in the capture cost are predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗